• 제목/요약/키워드: ignition hazard

검색결과 84건 처리시간 0.024초

다단 반응을 고려한 수소-공기 예혼합 화염의 발생 및 전파 (Onset and Propagation of Hydrogen-Air Premixed Flame with Multiple Kinetics)

  • 한조영;백승욱
    • 한국전산유체공학회지
    • /
    • 제9권1호
    • /
    • pp.25-33
    • /
    • 2004
  • Flame onset and propagation within hydrogen premixed gas mixture are numerically investigated in an rectangular enclosure. A detailed chemistry for hydrogen reaction is applied to anticipate the thermochemical behavior of intermediate species appropriately. To facilitate computation, 10 species and 16 elementary reaction steps for hydrogen combustion are taken into account. On the basis of 30% of hydrogen concentration in hydrogen-air mixture, the effects of position and quantity of ignition sources on the flame evolution are analyzed. From the simulation results, the methods to decrease the potential hazard caused by the flame propagation are suggested.

모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구 (Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer)

  • 문현욱;이기연;김동우;길형준;김향곤
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

Ethylene Glycol과 물의 혼합비에 따른 자연발화온도 특성 (Characteristic of Auto Ignition Temperature due to the Mixture Ratio of Ethylene Glycol and Water)

  • 김정훈;최재욱
    • 한국화재소방학회논문지
    • /
    • 제30권1호
    • /
    • pp.24-30
    • /
    • 2016
  • 자연발화 특성은 가연성물질의 취급 및 화재예방을 위한 중요한 인자이다. 본 연구는 ASTM D2155식 발화온도 측정장치를 사용하여 Ethylene Glycol과 물을 혼합한 시료의 자연발화 특성을 고찰하였다. Ethylene Glycol 100%는 시료량 $75{\mu}l{\sim}160{\mu}l$의 범위에서 $434^{\circ}C$로 나타났다. 물을 첨가하여 Ethylene Glycol 80%와 물 20%를 혼합한 시료는 시료량 $100{\mu}l{\sim}125{\mu}l$의 범위에서 $434^{\circ}C$로 나타났고, Ethylene Glycol 60%와 물 40%를 혼합한 시료에서 시료량 $120{\mu}l{\sim}160{\mu}l$의 범위에서 $437^{\circ}C$로 나타났다. 또한 순간발화온도는 시료량 $125{\mu}l$에서 각각 $579^{\circ}C$, $595^{\circ}C$$611^{\circ}C$를 구하였으며, 물의 비율이 증가할수록 자연발화온도와 순간발화온도는 증가되는 것으로 나타났다.

겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구 (Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제10권4호
    • /
    • pp.583-597
    • /
    • 2014
  • 난방기기에 의한 화재는 다양한 난방기기의 종류처럼 그 원인도 다양하고. 매년 계속되는 전통재래시장에서의 난방기기에 의한 화재사고가 빈번히 발생하여 인명 및 재산상의 손실을 초래하고 있다. 일반주택이나 아파트 등 대부분의 주거시설은 난방용 보일러가 보급되어 난방기기로 인한 화재가 그리 많지 않으나 식당, 시장의 점포와 사무실, 체육관, 공장, 작업장 등에서는 여전히 석유난로, 전기난로 등 난방기기를 사용 하고 있어 화재의 위험성에 노출되어 있다. 또한 난방용 기기의 발생건수를 살펴보면 가정용보일러, 목탄난로, 석유난로, 가스난로/스토브, 전기스토브/히터 순으로 발생한 것으로 분석되었으며, 인명피해 별 건수는 가스난로/스토브, 석유난로 /곤로, 전기히터/스토브, 연탄/석탄난로 순으로 분석되었다. 또한 가스 및 석유관련 난방용기기가 발생빈도(frequency)는 낮지만 화재강도(intensity)가 높은 것으로 분석 되었다. 따라서 본 연구의 목적은 다중이용시설인 전통재래시장에서 아직도 많이 사용되고 있고, 실제 화재발생사례가 많은 석유난로와 전기스토브에 의한 발화 위험성 즉 최소발화온도, 탄화 정도와 그에 따른 열유속을 정상상태와 비정상상태 하에서의 가연물의 접촉 및 전도로 인한 화재 발생 가능성을 재연하여 검토해 봄으로서 보다 과학적인 화재조사 및 감식 접근방법을 강구하고자 하였다. 재연실험 결과 실험체 2종(석유난로/전기스토브) 모두 양호한 축열 조건이 만들어지지 않는 한 발화위험성은 극히 적은 것으로 나타났지만 탄화의 상태는 각 부위별로 진행되는 것으로 분석되었다. 결국 화재로의 전이는 축열에 의한 발화이므로 최소한 화재장소의 축열 온도조건이 $500^{\circ}C$ 이상일 때 발화되는 것으로 분석되었다. 특히 전기스토브의 발열체인 석영관인 경우 가장 짧은 시간 내(10sec)에 $600^{\circ}C$ 이상의 온도로 급 가열 되어 이때의 열유속은 6.26kW/m2으로 나타나 이는 보온된 PVC케이블이 손상과 함께 인체에는 2도 화상을 입히는 결과를 나타내는 것으로 분석 되었다. 아울러 온도 조건 이외에 거리변화에 따른 열량의 감소분을 나타내는 형태계수(Geometric View Factor)와 화재하중(Fire Load)에 따른 온도 변화도 고려되어야 할 중요한 변수임 알았다. 따라서 이에 관한 세심한 화재조사 및 감식의 매뉴얼이 있어야 할 것으로 사료되며 이러한 실험에 의한 과학적이고 합리적인 노력들이 향후 화재조사 및 감식에 대한 매뉴얼 작성과 이론적 토대를 세우는데 기여하기를 기대한다.

자동차 내장재의 연소 특성에 관한 연구 (A Study on the Characteristics of Combustion for Car Interior Materials)

  • 김영탁;김해림;박영주;이해평
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.450-455
    • /
    • 2008
  • We have carried out the test using the cone calorimeter and the smoke density chamber to evaluate the characteristics of the combustion for the car interior materials passed horizontal burning test. We have analysed many parameters related to fire hazard. These parameters are the ignition time, the heat release rate, the maximum average rate of heat emission, the flashover propensity and specific optical density. There was a significant difference in HRR and optical smoke density. The HRR was $185{\sim}446kW/m^2$ and optical smoke density was $119{\sim}1207$. Only horizontal burning test was performed to evaluate the fire hazard for the car interior materials.

  • PDF

쌀겨 분진의 연소 및 폭발 위험성에 관한 연구 (Study on Combustion and Explosion Hazard of Rice Bran Dusts)

  • 이창우;현성호;이한철;허윤행
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.93-98
    • /
    • 1999
  • We had investigated combustion properties of rice bran dusts. Decomposition of rice bran dusts with temperature were investigated using DSC and the weight loss according to temperature using TGA in order to find the thermal hazard of rice bran dusts, and the properties of dust explosion in variation of their dust with the same particle size. Using Hartman's dust explosion apparatus which estimate dust explosion by electric ignition after making dust disperse by compressed air, dust explosion experiments have been conducted by varying concentration and size of rice bran dust.According to the results for thermodynamic stability of rice bran dust, there are little change of initiation temperature of heat generation and heating value for used particle size. But initiation temperature of heat generation decreased with high heating rate whereas decomposition heat increased with particle size. Average maximum explosion pressure was $10kgf/cm^2$ for 60/70 mesh and $1.5mg/cm^2$ dust concentration.

  • PDF

형광등용 안정기의 발화 및 용융흔 분석에 관한 연구 (A Study on the Ignition and Molten Mark Analysis of Ballast for Fluorescent Lamp)

  • 최충석;박창수;김혁수;김향곤;정재희
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1998년도 추계 학술논문발표회 논문집
    • /
    • pp.173-177
    • /
    • 1998
  • In this paper, we reported an outbreak of fire hazard of ballast for fluorescent lamp. The surface structure and composition of ballast coil analyzed by using metallurgical microscope, scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of molten mark appeared columnar structure and void. EDX analysis indicated that the molten mark spectra were composed not only of the corresponding original spectra but also of several new lines.

  • PDF

바닥내장재의 연소특성 분석에 관한 연구 (A Study on Analysis of Characteristics Combustion of Floor Covering Materials)

  • 박영주;이해평;김현주
    • 한국방재학회 논문집
    • /
    • 제10권3호
    • /
    • pp.77-83
    • /
    • 2010
  • 본 연구에서는 건축물 내장재 가운데 바닥재의 화재특성을 평가하기 위하여 목재, 모노륨, 장판지, 니스코팅 된 장판지 등 4종의 바닥재를 대상으로 콘칼로리미터, 발화온도시험기, 열중량분석기, 한계산소지수시험기 등을 이용하여 착화성, 발열특성, 난연성과 같은 연소특성을 분석하였다. 모노륨은 발화온도가 $325^{\circ}C$로 가장 낮았으며, 장판지와 니스코팅 된 장판지는 비교적 빠른 시간인 7초 이전에 착화가 시작되었다. 총열방출량은 목재가 $100MJ/m^2$로 가장 높게 나타났지만 최대열방출율은 니스코팅된 장판지가 가장 높은 것으로 나타났다. 열중량분석 결과, 모든 바닥재들이 $300{\sim}400^{\circ}C$ 온도구간에서 급격한 중량감소를 보였으며, 한계산소지수는 장판지와 니스코팅 된 장판지가 20~21% 정도이고 목재는 34%로 나타났다. 본 연구결과를 살펴보면, 모노륨, 장판지, 니스코팅 된 장판지는 착화가 빠르고 연소가 용이한 반면, 발열량은 낮은 것을 알 수 있었으며, 목재는 비교적 착화위험성이 낮고 난연성은 좋지만 발열량이 높은 것으로 나타났다.

건물 내장재의 화재위험성 평가 방법 (A Fire Hazard Assessment of Interior Finish Materials)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-28
    • /
    • 1998
  • 건물 화재시 예상되는 내장재의 실째 화재성농올 기준으로 한 위험성 명가방법올 제시하였다. 이률 위해 ISO Room Corner Test. (9705)를 기준으로 Qui ntie re의 화재확산 모델을 이용하여 내장재의 열 적 특성과 플래쉬 오버 도달시간과의 상관성을 유도하고 스쩨덴의 실제 시험결과와 비교 분석하였다. 이 결과, 내장재의 상대척인 화재위험성은 화재확산 변수 b륨 기준으로 명가될 수 있었다.

  • PDF

정전기 방전 평가를 위한 간이형 도구 개발에 관한 연구 (A Study on the Development of Simulating Tool for Evaluation of Electrostatic Discharge)

  • 최상원
    • 한국안전학회지
    • /
    • 제26권3호
    • /
    • pp.15-22
    • /
    • 2011
  • Explosion and fire cause about 30 reported industrial major accidents a year by ignition source which discharge of electrostatic generated to flammable gas, vapor, dust and mixtures. It brings economically and humanly very large loss that accident was caused by fire and explosion from electrostatic discharge. Thus, it is very important that electrostatic discharge energy is to be control below not to be igniting flammable mixtures. There are two kinds of analysis model for electrostatic discharge, human body model and machine model. Human body model is available the parameter of human's electrical equivalent that capacitance is 100 pF, resistance is $1.5k{\Omega}$. To simulate and visualize the electrostatic discharge from human body need a very expensive and high voltage simulator. In this paper, we measured the value of capacitance and resistance concerned with test materials and sizing of specimen and the value of charged voltage concerned with test specimen and distance to develop an electrostatic charge/discharge simulating tool for teaching with which concerned industrial employee and students. The result of experiments, we conformed that the minimum ignition energy of methane-oxygen mixtures meets well the equation $W=1/2CV^2$, and found out that the insulating material and sizing of equivalent value having human body mode are the poly ethylene of 200 mm and 300 mm of diameter. Developed electrostatic charge/discharge simulating tool has many merits; simple mechanism, low cost, no need of electric power and so on.