• 제목/요약/키워드: ignition current

Search Result 158, Processing Time 0.028 seconds

Design and Implementation of Electric Current Control Device for Ignition Coil in Spark Ignition Engine (스파크 점화기관의 점화코일 전류제어장치 설계 및 구현)

  • Lee, Geum-Boon;Choi, Seok-Won;Kim, Doo-Hyun;Cho, Beom-Oon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2682-2688
    • /
    • 2012
  • In this paper, we design and implement a electric current controller for ignition coil to measure the amount of current and to supply the additional current under vehicle driving conditions in spark ignition engines. The proposed controller can provide the stable current and prevent the overcurrent by measuring the amperage of primary ignition in real time. Also it enhances the performance of vehicle engine by controling the amount of ignition energy that make power increase and fuel burn more completely. The power and torque of the normal vehicle is evaluated as performance index for the experimental validation of the control module. The experimental results using dynamometer equipment show that after control module-mounted elevates the average of 10% more in both power and torque compared with before module-mounted.

New Ignition Method and Ignition Recognition Logic for a Microturbine (마이크로터빈의 새로운 점화 기법과 점화 인식 로직 개발)

  • Kim, Gi-Rae;Choi, Young-Kyu;Rho, Min-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.179-186
    • /
    • 2007
  • This paper presents new ignition method and ignition recognition logic for a microturbine. New ignition method is designed by constant speed control of a microturbine with pre-determined time during a ignition period. It make more accurate air-fuel ratio as well as give enough time to ignition system to have full performance under cold temperature. And ignition recognition logic is designed by observing output current change of inverter by generating output torque of a microturbine in the instant of ignition. For filtering a output torque current of inverter with high frequency, we applied a moving average method. So far, ignition recognition is usually implemented by measuring of exhausted gas temperature(EGT) of microturbine. The proposed logic can give more accurate judgement of ignition as well as keep a good working of starting system under out of order a temperature measuring system and biased initial value of EGT sensor. Finally, the two proposed logics are proved by field operating a microturbine under various conditions.

Surge Characteristics Analysis of Three-phase Virtual Chopping at Vacuum Circuit Breaker (진공차단기 3상 동시 차단시의 서지 특성 분석)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1159-1164
    • /
    • 2018
  • Vacuum circuit breakers(VCB) are widely used for current interruption of high-voltage inductive loads such as induction motors. This VCB can be chopped off before the current zero due to its high arc-extinguishing capability. One of the outstanding features of VCB is that it can cut off high frequency re-ignition current more than other circuit breakers. If the transient recovery voltage generated in the arc extinguishing is higher than the dielectric strength of the circuit breaker, a re-ignition phenomenon occurs. The surge voltage of the re-ignition is very high in magnitude and the steepness of the waveform is so severe that it can act as a high electrical stress on the winding. If the high frequency current of one phase affects the other two phases when the re-ignition occurs, it may cause a high surge voltage due to the virtual current chopping. If the magnitude of the voltage allowed in the motor winding is high or the waveform level is too severe, it may lead to insulation breakdown. Therefore, it is necessary to reduce the voltage to within a certain range. In this study, we briefly explain the various phenomena at the time of interruption, analyzed the magnitude of the dielectric strength and the transient recovery voltage at the simultaneous three-phase interruption that can give the greatest influence to the inductive load, proposed a method to reduce the impact.

A Study on The Ignition Limit of Flammable Gases by Discharge Spark of Resistive Circuit (저항회로의 개폐불꽃에 의한 폭발성 가스의 점화한계에 관한 연구)

  • Lee Chun-Ha
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.106-112
    • /
    • 1997
  • This study measured the ignition limits of methane-air, propane-air, ethylene-air, and hydrogen-air mixture gases by discharge spark of D.C. power resistive circuit. The used experimental device is the IEC type spark ignition test apparatus, it consists of explosion chamber and supply -exhaust system of mixture gas. Mixture gases (methane-air, propane-air, ethylene-air, and hydrogen-air) were put into explosion chamber of IEC type spark ignition test apparatus, then it was confirmed whether ignition was made by 3,200 times of discharge spark between tungsten electrode and cadmium electrode. The ignition limits were found by increasing or decreasing the value of current. For the exact experiment, the ignition sensitivity was calibrated before and after the experiment in each condition. The ignition limits were found by changing the value of concentration of each gas-air mixture in D.C. 24 [V] resistive circuit. As the result of experiment, it was found that the minimum ignition limit currents exist at the value of methane-air 8.3 [$Vol\%$], propane-air 5.25[$Vol\%$], ethylene-air 7.8 [$Vol\%$], and hydrogen-air 21[$Vol\%$] mixture gases. For each the minimum ignition concentration of gases, the relationships between voltage and minimum ignition current were found. The results are as follows. - The minimum ignition limits are decreasing in the order of methane, propane, ethylene, and hydrogen. - The value of ignition current is inversely proportional to the value of source voltage. - The minimum ignition limit currents increase sharply at more than 2 [A]. The reason is caused by overheating the electrode.

  • PDF

A Study of Measurement of Minimum Ignition Energy for Pine Tree Dust on Electrostatic Discharges (정전기 방전시의 소나무목분의 최소착화에너지 측정에 관한 연구)

  • 이동훈;박한석
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.74-79
    • /
    • 1998
  • To establish measuring method for minimum ignition energy of explosive powders caused by electrostatic discharge, A measuring method(Hartman) using a very small quantity of pine tree testing powder was proposed, and the influence of discharge current limiting resistance connected in series into a capacitive discharge circuit on ignition energies of explosive powders was investigated. As a result the minimum ignition energy was 42.25mJ when discharge current limiting resistance 300 $k\Omega$.

  • PDF

A New Optimal Design Method of the Electronic Ballast for MHL with Stable Run-up Current (시동전류 제한을 통한 메탈헬라이드 램프용 안정기의 최적 설계)

  • Lim, Byoung-Loh;Jang, Mog-Soon;Lim, Ki-Seung;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.409-415
    • /
    • 2008
  • This paper proposed a new optimal design method of the electronic ballast with stable run-up current for Metal Halide lamp during the ignition condition. In order to avoid operation in the acoustic resonance frequency band and to supply the optimal ignition current without demage of inverter switching components during the ignition period, the values of the series inductor Ls, the series capacitor Cs, and the parallel capacitor Cp were determined by analysis of characteristics of inverter transfer function depend on Lamp operating power and resistance of ignition condition and steady state operating condition. For the prototype ballast for a 400W Metal Halide Lamp, experimental results are presented in order to validate the proposed method.

A Study on the Development of Ignition Trans applied to Gas Boiler (가스보일러에 적용되는 점화 트랜스 개발에 관한 연구)

  • Lee, Ho-kyun;Kim, Jang-Won;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.6
    • /
    • pp.467-472
    • /
    • 2021
  • In this paper, the ignition trans used in the gas boiler was produced to measure current, power factor, and power consumption. As a result of measuring the power factor, the self-made ignition trans was higher than that of foreign products and the power consumption was lower. The ignition gap was fixed to 2 m, and when the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 3.45A, 14.5A, and 16.2A. When the ignition gap was fixed to 4mm and the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 2.8A, 10.1A, and 13.2A. When the ignition gap was fixed at 6mm and the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 2.73A, 10.2A, and 32.6A. When the ignition gap was fixed at 8 mm and the ignition rod length was 30 cm, 500cm, and 1000cm, it was measured as 3.13A, 9.37A, and 21.4. The ignition gap was fixed at 10 mm, and when the ignition rod length was 30cm, it was measured as 3.4A, 14.4 A, and 25.6A. In conclusion, as the length of the ignition rod increased, the current also increased.

An Experimental Study on the Ignition Characteristic of Ignition Plug (점화플러그의 점화특성에 관한 실험적 연구)

  • Sim, Sang-Cherl;Cho, Tae-Young;Jung, Byoung-Koog;Song, Kyu-Keun;Jung, Jea-Youn;Kim, Hyung-Gon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2088-2093
    • /
    • 2004
  • Harmful elements from the exhaust gases are caused by incomplete combustion of mixture inside the engine cylinder and this abnormal combustion like misfire or partial burning is the direct cause of the air pollution and engine performance degradation. In this study, I obtain the shapes of spark, voltage and current generated when changing the experimental parameters such as grounded electrode shapes, electrode gap and the material of center electrodes. After that, I produce ignition energy by using the voltage and current and classify ignition energy into capacitive discharge energy and inductive discharge energy.

  • PDF

Electromagnetic effect by ignition current in vehicle (차량에서 Ignition current 변화에 따른 자기 유도에 의한 센서 출력 변화)

  • Lee, Dong-Ju;Kim, Cheol;Choe, Jang-Hyeon;Seong, Eun-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1611-1612
    • /
    • 2006
  • We are using the Faraday's electromagnetic law so as to improve our life in various industry fields. However, the side effect of the Faraday's law can be occurredin the sensors of the vehicle due to the high current flow such as Ignition. This effect is mainly caused by the shape of the wiring harness between sensor and high current load in the vehicle. To minimize the side effect by Faraday's law, three methods shall be considered in this paper (1) Pin definition of the sensor, (2) Pin definition of the high current load, (3) Wiring harness shape.

  • PDF

Study on the Ageing of Glow Starter for Fluorescent Lamp (형광등용 점등관의 에이징에 관한 연구)

  • 지철근
    • 전기의세계
    • /
    • v.22 no.2
    • /
    • pp.23-27
    • /
    • 1973
  • An initial starting voltage, ignition time, glow current and blink of the flow starter are changed rapidly in initial using. therefore an ageing is required to stabilize the initial characteristics. According to the experiments, it is proved that the ageing time for the starting voltage and glow current takes 3 minutes and 5 minutes for ignition time and blink.

  • PDF