Abstract
In this paper, the ignition trans used in the gas boiler was produced to measure current, power factor, and power consumption. As a result of measuring the power factor, the self-made ignition trans was higher than that of foreign products and the power consumption was lower. The ignition gap was fixed to 2 m, and when the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 3.45A, 14.5A, and 16.2A. When the ignition gap was fixed to 4mm and the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 2.8A, 10.1A, and 13.2A. When the ignition gap was fixed at 6mm and the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 2.73A, 10.2A, and 32.6A. When the ignition gap was fixed at 8 mm and the ignition rod length was 30 cm, 500cm, and 1000cm, it was measured as 3.13A, 9.37A, and 21.4. The ignition gap was fixed at 10 mm, and when the ignition rod length was 30cm, it was measured as 3.4A, 14.4 A, and 25.6A. In conclusion, as the length of the ignition rod increased, the current also increased.
Keywords
gas boiler; current; ignition gap; ignition trans; ignition rod length; power factor; power consumption;
Citations & Related Records
연도 인용수 순위
  • Reference
1 C.N.Park, L.H.Kim,"A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW",Journal of Energy Engineering, Vol. 25, No. 3, pp.73~82, 2016   DOI
2 Park, I.S., Kim, H.K., "The Characteristic of Combustion on Flat Plate Type Premixing Surface Combustion Gas Burner and Applied Cases", KOSCO SYMPOSIUM 284-289, 2008
3 Korea Gas Safety Corporation., KGS Code AB131- Facility/ Technical/ Inspection Code for Manufacture of FE and FF Type Gas boiler, Korea Gas Safety Corporation Technical standard division, pp. 38-39, 2016,
4 Korean Standards Association., "KS B 8127 : Domestic hot water gas condensing boiler, Ministry of Trade, Industry and Energy Korea Agency for Technical and Standards, pp.19, 2014,
5 K.B.Lee,"Research for Development of Gas Boiler",The Society Of Air-Conditioning And Refrigerating Engineers Of Korea, Vol.19, No.41, pp.23-27, 1991.
6 T.G. Kim, "The advantage of contin -uous heating using a gas boiler as a heat source.",The Society Of Air- Conditioning And Refrigerating Engin -eers Of Korea, No.4, pp.23-42, 1989
7 Park, B.I., Lee, P.H., Cho, S. H., Juaracteristics of Cylindrical Flat Premixed Burner for Condensing Boiler", KOSCO SYMPOSIUM, pp. 287 - 291, 2010
8 Korean Standards Association,"KS B 8100 : Gas appliance technical terms, Ministry of Trade, Industry and Energy Korea Agency for Technical and Standards, pp. 12, 2015,
9 Korean Standards Association., "KS B 8109 : Domestic hot water gas boiler, Ministry of Trade, Industry and Energy Korea Agency for Technical and Standards, pp. 20-21, 2014,
10 J.D. Dale, M.D. Checkel, P.R. Smy, "Application of High Energy Ignition Systems to Engines", Progress in Energy and Combustion Science, 23(5-6): 379-398, 1997, doi: 10.1016/S0360-1285(97)00011-7.64   DOI
11 X. Yu, S. Yu, Z. Yang, Q. Tan, M. Ives, L. Li, M. Liu, M. Zheng, "Improvement on Energy Efficiency of the Spark Ignition System", SAE Technical Paper, doi: 10.4271/2017-01-0678.