• Title/Summary/Keyword: iEMG

Search Result 106, Processing Time 0.156 seconds

Effect of Saddle to Pedal Length in Kayak Ergometer on Rowing Motion and EMG Activation in Elite Kayak Players (엘리트 카약 선수들의 에르고미터를 이용한 로잉 동작 시 안장과 페달의 거리가 로잉 패턴 및 근 활성도에 미치는 영향)

  • Ryue, Jae-Jin;Nam, Ki-Jung;Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • The purpose of this study was to identify the saddle to pedal length contributing to successful performance in kayak using a kayak ergometer. Ten male elite kayak players participated in this study. players were tested on the kayak ergometer which was varied saddle to pedal length by the knee flexion angle(90deg; 120deg; 150deg) to measure stroke frequency, paddling amplitude, joint angle, RoM and angular velocity, foot pressure and force, iEMG using the 3D motion system, foot pressure system and EMG wireless system. At a results, rowing at 120deg on knee flexion angle showed higher stroke frequency and paddling amplitude than other knee flexion angles. RoM at upper extremity showed not significant difference between knee flexion angles. But there were significant differences in thorax and pelvis rotation RoM, knee flexion-extension RoM in each condition. In addition, foot pressure, force and iEMG were significantly different in knee flexion angles. Study showed that changed of saddle to pedal length affected rowing performance kinds of stroke frequency, paddling amplitude. The most important thing, increased range of motion in pelvic and thorax has occurred by force that generated foot-bar to seat. Not only that, but it seems to be attributed to a technical adaptation developed to maximum rowing performance.

Effect of Muscle Pre-activation Properties on the Magnitude of Joint Torque during Voluntary Isometric Knee Extension (등척성 무릎 토크 발생 시 사전활성화 유형의 차이가 최대 자발적 토크 생성에 미치는 영향)

  • Kim, Jong-Ah;Shin, Narae;Lee, Sungjune;Xu, Dayuan;Park, Jaebum
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.140-147
    • /
    • 2021
  • Objective: The purpose of this study is to identify the mechanism of changes in maximum voluntary torque with the magnitude and duration of pre-activation torque during voluntary isometric knee extension. Method: 11 male subjects (age: 25.91±2.43 yrs., height: 173.12±3.51 cm, weight: 76.45±7.74 kg) participated in this study. The subjects were required to produce maximal voluntary isometric torque with a particular pre-activation torque condition. The properties of pre-activation torque consisted of the combinations of 1) three levels of magnitude, e.g., 32 Nm, 64 Nm, 96 Nm, and 2) two levels of duration, e.g., 1 sec, and 3 sec; thus, a total of six conditions were given to the subjects. The force and EMG data were measured using the force transducers and wireless EMG sensor, respectively. Results: The results showed that the maximum voluntary torque increased the most with relatively large and fast (96 Nm, 1 sec) pre-activation condition. Similarly, with relatively large and fast (96 Nm, 1 sec) preactivation, it was found that the integrated EMG (iEMG) of the agonist muscles increased, while no significant changes in the co-contraction of the antagonist muscles for the knee extension. Also, the effect of pre-activation conditions on the rate of torque development was not statistically significant. Conclusion: The current findings suggest that relatively larger in magnitude and shorter in duration as the properties of pre-activation lead to a larger magnitude of maximal voluntary torque, possibly due to the increased activity of the agonist muscles during knee extension.

A study on the ENG Signal Processing for Multichannel System (다중 채널을 갖는 근전도의 신호처리에 관한 연구 (I))

  • Kwon, J.W.;Jang, Y.G.;Jung, K.H.;Min, M.K.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.25-29
    • /
    • 1991
  • In the field of prosthesis arm control, tile pattern classification of the EMG signal is a required basis process and also the estimation of force from col looted EMG data is another necessary duty. But unfortunately, what we've got is not real force but an EMG signal which contains the information of force. This is the reason why he estimate the force from the EMG data. In this paper, when we handle the EMG signal to estimate the force, spatial prewhitening process is applied from which the spatial correlation between the channels are removed. And after the orthogonal transformation, which is used in the force estimation process the transformed signal is inputed into the probabilistic model for pattern classification. To verify the different results of the multiple channels, SNR(signal to noire ratio) function is introduced.

  • PDF

Effect of Acupuncture (Hapkok, LI-4) Based on Retaining Time on Pain in Rats (침법(鍼法)에 따른 합곡혈(合谷穴) 자극(刺戟)이 동통억제(疼痛抑制)에 미치는 영향(影響))

  • Yun Y.C.;Choi K.J.;Chae W.S.;Na C.S.;Song H.K.
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.319-329
    • /
    • 1998
  • The purpose of this study was finding the pain inhibitory effect of acupuncture based on rataining time at LI -4. The pain at dentes incisor was evoked by noxious electric stimulation and digastric electromyogram(dEMG) changes based on time interval were measured. To do this, the opioid antagonist was administered intraperitoneally and four groups were made for convenience. Without naloxone, dEMG was changed by either retaining the needle for 40 minutes (Group I) or by lifting and thrusting the needle (Group II). With naloxone administration, dEMG was changed by either retaining the needle for 40 minutes (Group III) or by lifting and thrusting the needle (Group IV). The results are as following 1. The pain inhibitory effect of acupuncture at LI -4 was expressed best in Group I. 2. The pain inhibitory effect was somewhat expressed in Group II but the effect was smaller than Group I. 3 .In Groups III and IV, the pain inhibitory effect was not expressed. The overall result should be the foundation for the further studies to figure out the underlying mechanism of acupuncture. In addition, it is assumed that the results will be useful for optimal retaining time of acupucture for its maximal effect.

  • PDF

Influence of the Knee Angles on the Electromyographic Activites and Fatigue of the Ankle Muscles in Healthy Subjects (무릎관절 각도가 발목 근육의 근전도 활동에 미치는 영향)

  • Yu, Gyeong-Seok;Kim, Taek-Yean
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.16-26
    • /
    • 2006
  • The purpose of this study was to investigate the influence of the various knee angles and ground state on the muscular activities and fatigue of the ankle muscles by integrated electromyograms (iEMG) and median frequency of tibialis anterior (TA), peroneus longus (PL), flexor digitorum longus (FDL) and gastrocnemius (GC). Ten healthy male subjects were participated into stable and balance ball sessions at four angles of knee joint. The surface electromyograms (sEMG) were recorded from the TA, PL, FDL and GC on stable and balance ball with full weight bearing at four knee angles of $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$. The time serial data of the surface electromyographic signals were transformed into integrated and frequency serial data by fast fourier transformation. On the stable ground, the iEMG signals of the TA, PL, FDL and GC were significantly higher at $45^{\circ}$ and $30^{\circ}$ of knee angles than $0^{\circ}$ and $15^{\circ}$ of knee flexion (p<0.05). On the balance ball, the iEMG of the TA, PL, FDL and GC were significantly higher at $45^{\circ}$ and $30^{\circ}$ of knee angles than $0^{\circ}$ and $15^{\circ}$ of knee flexion (p<0.05). The median frequency of the TA, PL, FDL and GC were significantly lower at $45^{\circ}$ and $30^{\circ}$ of knee angles than $0^{\circ}$ and $15^{\circ}$ of knee on the stable ground (p<0.05). On the balance ball, also the median frequency of the TA, PL, FDL and GC were significantly lower at $45^{\circ}$ and $30^{\circ}$ of knee angles than $0^{\circ}$ and $15^{\circ}$ of knee flexion (p<0.05). The iEMG of the TA, PL, FDL and GC were significantly higher on the balance ball at $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of knee angles compared with stable ground. The median frequency of the TA, PL, FDL and GC were significantly lower on the balance ball at $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of knee angles compared with stable ground. These results indicate that the ground conditions and angles of the knee joint involved to muscular activities and fatigue of ankles muscles, may performed at first on stable ground and then balance ball in order to $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of knee flexion.

  • PDF

Strength Evaluation of Sin91e-Radius Total Knee Replacement (TKR) (인공무릎관절의 단축법위 회전시 근력정가)

  • Wan, Jin-Young;Sub, Kwak-Yi
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.484-489
    • /
    • 2004
  • Artificial joint replacement is one of the major surgical advances of the 21th century. The primary purpose of a TKA (Total Knee Arthroplasty) is to restore normal knee Auction. Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from a chair or climbing stairs;(b) allow the same range of motion as an complete knee; and (c) provide adequate knee joint stability. Four individuals (2 peoples after surgery one year and 2 peoples after surgery three years) participated in this study. All they were prescreened for health and functional status by the same surgeon who performed the operations. Two days of accommodation practice occurred prior to the actual strength testing. The isometric strength (KIN-COM III) of the quadriceps and hamstring were measured at 60$^\circ$ and 30$^\circ$ of knee flexion, respectively. During isokinetic concentric testing, the range of motion was between 10$^\circ$ to 80$^\circ$ of knee flexion (stand-to-sit) and extension (sit-to-stand). for a given test, the trial exhibiting maximum torque was analyzed. A 16-channel MYOPACTM EMG system (Run Technologies, Inc.) was used to collect the differential input surface electromyographic (EMG) signals of the vastus medialis (VM), vastus lateralis(VL), rectus femoris (RF) during sit-to-stand and stand-to-sit tests. Disposable electrodes (Blue SensorTM, Medicotest, Inc.) were used to collect the EMG signals. The results were as follows; 1. Less maximum concentric (16% and 21% less for 1 yew man and 3 years mm, respectively) and isometric (12% and 29%, respectively) quadriceps torque for both participants. 2.14% less maximum hamstrings concentric torque for 1 year man but 16% greater torque for 3 years mm. However, 1 year man had similar hamstring isometric peak torque for both knees. 3. Less quadriceps co-contraction by 1 year man except for the VM at 10$^\circ$-20$^\circ$ and 30$^\circ$-50$^\circ$ range of knee flexion.

An Algorithm for Distinction between Denervation Potentials and Endplate Spikes on EMG Diagnosis (근전도 검사에서 나타나는 탈신경전위와 종판전위의 구별을 위한 알고리듬)

  • Choi, H.B.;Hwang, Y.S.;Park, I.S.;Im, J.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.383-386
    • /
    • 1997
  • In the EMG evaluation, the neuropathy may be diagnosed by a detection of denervation potentials in the group of muscles. These abnomal potentials might be confused with normal endplate spikes. In this paper we present the software algorithm in C, which automatically detects spontaneous activity such as denervation potentials and endplate potentials and distingushes between those potentials. Parameters with statistically significant differences were used for this automated algorithm. It was concluded that the algorithm established in this study will improve accuracy in EMG diagnosis.

  • PDF

Speed improvement of EMG signal decomposition for clinical diagnosis (임상진단을 위한 근신호 분리의 속도 개선)

  • Kim, G. H.;Kim, J. W.;Kim, K. S.;Cho, I. J.;Lee, J.;Kim, H. S,
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.559-563
    • /
    • 1990
  • A new speed improvement method for quantitative superimposed EMG signal analysis to diagnose the neuromuscular dysfunction is described. The improvement is achieved through the use of efficient software and hardware signal processing techniques. The software approch is composed of the MANDF filter and HRWA algorithm which provides the optimal set and time delays of-selected templates. The hardware employs a TMS32OC25 DSP chip to execute the intensive calculation part. The purposed method is verified through a simulation with real templates which are obtained from needle EMG. As a results, the proposed method provides an overall speed improvement of 32-40 times.

  • PDF

Acoustic, Intraoral Air Pressure and EMG Studies of Vowel Devoicing in Korean

  • Kim, Hyun-Gi;Niimi, Sei-Ji
    • Speech Sciences
    • /
    • v.10 no.1
    • /
    • pp.3-13
    • /
    • 2003
  • The devoicing vowel is a phonological process whose contrast in sonority is lost or reduces in a particular phonetic environment. Phonetically, the vocal fold vibration originates from the abduction/adduction of the glottis in relation to supraglottal articulatory movements. The purpose of this study is to investigate Korean vowel devoicing by means of experimental instruments. The interrelated laryngeal adjustments and aerodynamic effects for this voicing can clarify the redundant articulatory gestures relevant to the distinctive feature of sonority. Five test words were selected, being composed of the high vowel /i/, between the fricative and strong aspirated or lenis affricated consonants. The subjects uttered the test words successively at a normal or at a faster speed. The EMG, the sensing tube Gaeltec S7b and the High-Speech Analysis system and MSL II were used in these studies. Acoustically, three different types of speech waveforms and spectrograms were classified, based on the voicing variation. The intraoral air pressure curves showed differences, depending on the voicing variations. The activity patterns of the PCA and the CT for devoicing vowels appeared differently from those showing the partially devoicing vowels and the voicing vowels.

  • PDF

Muscle Contraction and Relaxation Pattern Analysis of Spinal Cord Injured Patient (척추 손상 환자의 근신호 수축 및 이완 패턴 분석)

  • Lee, Y.S.;Lee, J.;Kim, H.D.;Park, I.S.;Ko, H.Y.;Kim, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.398-401
    • /
    • 1997
  • The EMG signal of spinal cord injured patient is very feeble because that the information from central nervous system is not sufficiently transmitted to molter neuron or muscle fiber. Therefore the observer can not observe contraction and relaxation movement of muscle from the raw EMG signal. In this paper, we propose the muscle contraction and relaxation pattern analysis method of spinal cord injured patient whose EMG signal is composed of the sum of motor unit action potential train with additive white Gaussian noise and impulsive noise. From the EMG model, we denoise impulsive noise using median filter which is a kind of nonlinear filter and the output of median filter is transformed to wavelet transform domain for denoising additive white Gaussian noise using threshold level removal technique. As a result, we can obtain the clear contraction and relaxation pattern.

  • PDF