• 제목/요약/키워드: hysteresis performance

검색결과 440건 처리시간 0.024초

Numerical investigation seismic performance of rigid skewed beam-to-column connection with reduced beam section

  • Zareia, Ali;Vaghefi, Mohammad;Fiouz, Ali R.
    • Structural Engineering and Mechanics
    • /
    • 제57권3호
    • /
    • pp.507-528
    • /
    • 2016
  • Reduced beam section (RBS) moment resisting connections are among the most economical and practical rigid steel connections developed in the aftermath of the 1994 Northridge and the 1995 Kobe earthquakes. Although the performance of RBS connection has been widely studied, this connection has not been subject to in the skewed conditions. In this study, the seismic performance of dogbone connection was investigated at different angles. The Commercial ABAQUS software was used to simulate the samples. The numerical results are first compared with experimental results to verify the accuracy. Nonlinear static analysis with von Mises yield criterion materials and the finite elements method were used to analyze the behavior of the samples The selected Hardening Strain of materials at cyclic loading and monotonic loading were kinematics and isotropic respectively The results show that in addition to reverse twisting of columns, change in beam angle relative to the central axis of the column has little impact on hysteresis response of samples. Any increase in the angle, leads to increased non-elastic resistance. As for Weak panel zone, with increase of the angle between the beam and the column, the initial submission will take place at a later time and at a larger rotation angle in the panel zone and this represents reduced amount of perpendicular force exerted on the column flange. In balanced and strong panel zones, with increase in the angle between the beam and the central axis of the column, the reduced beam section (RBS), reaches the failure limit faster and at a lower rotation angle. In connection of skewed beam, balanced panel zone, due to its good performance in disposition of plasticity process away from connection points and high energy absorption, is the best choice for panel zone. The ratio of maximum moment developed on the column was found to be within 0.84 to 1 plastic anchor point, which shows prevention of brittle fracture in connections.

준능동 동조질량감쇠기의 탄성 및 비탄성 지진응답 제어성능 평가 (Performance Evaluation of Semi-Active Tuned Mass Damper for Elastic and Inelastic Seismic Response Control)

  • 이상현;정란;우성식;조승호
    • 한국지진공학회논문집
    • /
    • 제11권2호
    • /
    • pp.47-56
    • /
    • 2007
  • 본 연구에서는 지진하중을 받는 탄성 및 비탄성 구조물에 대하여 수동 및 준능동 TMD의 지진응답제어성능을 평가하였다. 먼저 기존의 연구에서 제안된 식을 사용하여 최적 설계된 수동형 TMD와 본 연구에서 제시된 준능동 TMB가 설치된 탄성 구조물의 변위스펙트럼을 구하였으며, 준능동 TMD가 TMD보다 작은 스트로크를 가지고도 최대변위응답제어에 있어 우수함을 확인하였다. 또한 구조물의 주기와 TMD의 주기가 일치하지 않은 경우의 성능저하에 대한 TMD의 강인성을 평가하였다. 최종적으로 Bouc-Wen 모델을 사용하여 모사된 비탄성이력 특성을 가지는 구조물에 대한 수치해석을 수행하였으며, 이를 통해 탄성구조물에 대하여 최적화된 수동형 TMD의 성능은 구조물 응답의 비탄성이력 부분이 증가함에 따라 크게 저하되는 반면 준능동 TMD는 수동형 TMD보다 약 15-40% 정도의 더 많은 응답감소효과를 가짐을 확인하였다.

Effect of soil in controlling the seismic response of three-dimensional PBPD high-rise concrete structures

  • Mortezaie, Hamid;Rezaie, Freydoon
    • Structural Engineering and Mechanics
    • /
    • 제66권2호
    • /
    • pp.217-227
    • /
    • 2018
  • In the last decades, valuable results have been reported regarding conventional passive, active, semi-active, and hybrid structural control systems on two-dimensional and a few three-dimensional shear buildings. In this research, using a three-dimensional finite element model of high-rise concrete structures, designed by performance based plastic design method, it was attempted to construct a relatively close to reality model of concrete structures equipped with Tuned Mass Damper (TMD) by considering the effect of soil-structure interaction (SSI), torsion effect, hysteresis behavior and cracking effect of concrete. In contrast to previous studies which have focused mainly on linearly designed structures, in this study, using performance-based plastic design (PBPD) design approach, nonlinear behavior of the structures was considered from the beginning of the design stage. Inelastic time history analysis on a detailed model of twenty-story concrete structure was performed under a far-field ground motion record set. The seismic responses of the structure by considering SSI effect are studied by eight main objective functions that are related to the performance of the structure, containing: lateral displacement, acceleration, inter-story drift, plastic energy dissipation, shear force, number of plastic hinges, local plastic energy and rotation of plastic hinges. The tuning problem of TMD based on tuned mass spectra is set by considering five of the eight previously described functions. Results reveal that the structural damage distribution range is retracted and inter-story drift distribution in height of the structure is more uniform. It is strongly suggested to consider the effect of SSI in structural design and analysis.

비탈형 거푸집에 의한 고강도 콘크리트의 폭렬방지 (Spalling Resistance of High Strength Concrete Using Non-Stripping Form)

  • 유지영;한창평;지석원;한민철;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.865-868
    • /
    • 2008
  • 본 연구에서는 최근 사용이 증대되고 있는 고성능 콘크리트의 폭렬현상을 방지하기 위해 일련의 연구 중 메탈라스 횡구속을 병행한 비탈형 거푸집을 사용한 고성능 콘크리트 RC기둥부재의 내화특성을 검토하였는데, 그 결과를 요약하면 다음과 같다. 유동성 및 공기량은 모두 목표 범위를 만족하였고, 압축강도는 재령 28일에서 80 MPa이상으로 고강도범위를 나타내었다. 폭렬 특성으로는 섬유를 혼입하지 않은 플레인의 경우는 심한 폭렬이 발생하였고, 나일론(이하 NY)+폴리프로필렌(이하 PP) 섬유를 0.05%를 혼입한 경우에는 표면부에만 부분적인 박리폭렬이 발생하였다. 비탈형 거푸집 변화에 따라서는 비탈형 25-20, 비탈형 50-20의 경우에는 모두 마 감재부분에 폭렬이 발생하였는데, 비탈형 50-20의 경우가 비탈형 25-20보다 양호한 폭렬방지 성능을 나타내었다. 비탈형 50-40의 경우는 폭렬이 방지되었는데 질량감소율은 10%이하로 나타났고, 온도이력은 모재표면부 최고온도가 $376.1^{\circ}C$로 가장 우수한 내화 성능을 나타내었다.

  • PDF

직접토크제어에 의한 위치검출기 없는 리럭턴스 동기전동기의 고성능 제어시스템 (A High-Performance Position Sensorless Control System of Reluctance Synchronous Motor with Direct Torque Control)

  • 김민회;김남훈;백원식
    • 전력전자학회논문지
    • /
    • 제7권1호
    • /
    • pp.81-90
    • /
    • 2002
  • 본 논문은 직접토크제어에 의한 리럭턴스 동기 전동기의 위치센서 없는 고성능 제어시스템을 제안한다. 이 시스템은 고정자 자속관측기, 속도/토크 관측기, 두 개의 디지털 히스테리시스 제어기, 최적 스위칭 룩업 테이블, IGBT 전압형 인버터, 그리고 TMS320C31 DSP보드로 구성된다. 넓은 속도 범위에서의 안정된 응답특성을 얻기 위해서 전동기 단자에서 얻어진 전압과 전류를 사용하는 폐루프 자속관측기를 사용하였다. 개발된 고성능 속도제어 시스템의 동특성을 검증하기 위해서 1.0[kW] 리럭턴스 동기 전동기를 사용하여 시뮬레이션과 실험을 수행한 결과 저속영역과 고속영역 모두 우수한 동특성을 얻을 수 있었다.

특수모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가 (Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections with Special Moment Frame Details)

  • 김선훈;이득행;김용겸;이상원;여운용;박정은
    • 한국지진공학회논문집
    • /
    • 제27권5호
    • /
    • pp.203-211
    • /
    • 2023
  • For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

Test for the influence of socket connection structure on the seismic performance of RC prefabricated bridge piers

  • Yan Han;Shicong Ding;Yuxiang Qin;Shilong Zhang
    • Earthquakes and Structures
    • /
    • 제25권2호
    • /
    • pp.89-97
    • /
    • 2023
  • In order to obtain the impact of socket connection interface forms and socket gap sizes on the seismic performance of reinforced concrete (RC) socket prefabricated bridge piers, quasi-static tests for three socket prefabricated piers with different column-foundation connection interface forms and reserved socket gap sizes, as well as to the corresponding cast-in-situ reinforced concrete piers, were carried out. The influence of socket connection structure on various seismic performance indexes of socket prefabricated piers was studied by comparing and analyzing the hysteresis curve and skeleton curve obtained through the experiment. Results showed that the ultimate failure mode of the socket prefabricated pier with circumferential corrugated treatment at the connection interface was the closest to that of the monolithic pier, the maximum bearing capacity was slightly less than that of the cast-in-situ pier but larger than that of the socket pier with roughened connection interface, and the displacement ductility and accumulated energy consumption capacity were smaller than those of socket piers with roughened connection interface. The connection interface treatment form had less influence on the residual deformation of socket prefabricated bridge piers. With the increase in the reserved socket gap size between the precast pier column and the precast foundation, the bearing capacity of the prefabricated socket bridge pier component, as well as the ductility and residual displacement of the component, would be reduced and had unfavorable effect on the energy dissipation property of the bridge pier component.

Evaluation of seismic performance factors for tension-only braced frames

  • Shariati, Mahdi;Lagzian, Majid;Maleki, Shervin;Shariati, Ali;Trung, Nguyen Thoi
    • Steel and Composite Structures
    • /
    • 제35권4호
    • /
    • pp.599-609
    • /
    • 2020
  • The tension-only braced frames (TOBFs) are widely used as a lateral force resisting system (LFRS) in low-rise steel buildings due to their simplicity and economic advantage. However, the system has poor seismic energy dissipation capacity and pinched hysteresis behavior caused by early buckling of slender bracing members. The main concern in utilizing the TOBF system is the determination of appropriate performance factors for seismic design. A formalized approach to quantify the seismic performance factor (SPF) based on determining an acceptable margin of safety against collapse is introduced by FEMA P695. The methodology is applied in this paper to assess the SPFs of the TOBF systems. For this purpose, a trial value of the R factor was first employed to design and model a set of TOBF archetype structures. Afterwards, the level of safety against collapse provided by the assumed R factor was investigated by using the non-linear analysis procedure of FEMA P695 comprising incremental dynamic analysis (IDA) under a set of prescribed ground motions. It was found that the R factor of 3.0 is appropriate for safe design of TOBFs. Also, the system overstrength factor (Ω0) was estimated as 2.0 by performing non-linear static analyses.

Cyclic loading behavior of high-strength steel framed-tube structures with replaceable shear links constructed using Q355 structural steel

  • Guo, Yan;Lian, Ming;Zhang, Hao;Cheng, Qianqian
    • Steel and Composite Structures
    • /
    • 제42권6호
    • /
    • pp.827-841
    • /
    • 2022
  • The rotation capacities of the plastic hinges located at beam-ends are significantly reduced in traditional steel framed-tube structures (SFTSs) because of the small span-to-depth ratios of the deep beams, leading to the low ductility and energy dissipation capacities of the SFTSs. High-strength steel framed-tube structures with replaceable shear links (HSSFTS-RSLs) are proposed to address this issue. A replaceable shear link is located at the mid-span of a deep spandrel beam to act as a ductile fuse to dissipate the seismic energy in HSSFTS-RSLs. A 2/3-scaled HSSFTS-RSL specimen with a shear link fabricated of high-strength low-alloy Q355 structural steel was created, and a cyclic loading test was performed to study the hysteresis behaviors of this specimen. The test results were compared to the specimens with soft steel shear links in previous studies to investigate the feasibility of using high-strength low-alloy steel for shear links in HSSFTS-RSLs. The effects of link web stiffener spaces on the cyclic performance of the HSSFTS-RSLs with Q355 steel shear links were investigated based on the nonlinear numerical analysis. The test results indicate that the specimen with a Q355 steel shear link exhibited a reliable and stable seismic performance. If the maximum interstory drift of HSSFTS-RSL is designed lower than 2% under earthquakes, the HSSFTS-RSLs with Q355 steel shear links can have similar seismic performance to the structures with soft steel shear links, even though these shear links have similar shear and flexural strength. For the Q355 steel shear links with web height-to-thickness ratios higher than 30.7 in HSSFTS-RSLs, it is suggested that the maximum intermediate web stiffener space is decreased by 15% from the allowable space for the shear link in AISC341-16 due to the analytical results.

콘크리트 댐 내진성능평가 시 감쇠비 적용 방안 고찰 (Study on the Application of Damping Ratio in the Seismic Performance Evaluation of Concrete Dams)

  • 오정근;정영석;권민호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권1호
    • /
    • pp.9-18
    • /
    • 2023
  • 이 논문의 목적은 콘크리트 댐의 내진성능평가 시 현행 설계기준과 평가요령에서 제시하는 감쇠비 값 크기에 대한 적용방안의 적정성을 검토하고 개선안을 제시하는 것이다. 연구결과 동적탄성해석 시 감쇠비의 크기는 지진하중의 크기가 유사하고 감쇠비에 대한 재현성이 검증된 유사댐의 사례를 참조할 필요가 있으며, 동적소성해석 시에는 지진하중의 크기와 상관없이 초기 탄성거동을 고려하여 감쇠비를 낮은값으로 적용하고 비선형 거동 시 이력감쇠가 추가되도록 고려할 필요가 있다. 또한 암반상에 위치한 콘크리트 댐체는 방사감쇠 효과가 미미하므로 방사감쇠를 반영하기 위해 콘크리트 댐체의 감쇠비를 증가시키는 것은 합리적이지 않다. 따라서 콘크리트 댐의 현실적인 내진성능평가를 위해 현행 댐 설계기준과 평가요령에 수록된 감쇠비 관련내용에 대해 개정이 필요하다.