• Title/Summary/Keyword: hydrogen refueling station

Search Result 71, Processing Time 0.021 seconds

Inplementation of a Hydrogen Leakage Simulator with HyRAM+ (HyRAM+를 이용한 수소 누출 시뮬레이터 구현)

  • Sung-Ho Hwang
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.551-557
    • /
    • 2024
  • Hydrogen is a renewable energy source with various characteristics such as clean, carbon-free and high-energy, and is internationally recognized as a "future energy". With the rapid development of the hydrogen energy industry, more hydrogen infrastructure is needed to meet the demand for hydrogen. However, hydrogen infrastructure accidents have been occurring frequently, hindering the development of the hydrogen industry. HyRAM+, developed by Sandia National Laboratories, is a software toolkit that integrates data and methods related to hydrogen safety assessments for various storage applications, including hydrogen refueling stations. HyRAM+'s physics mode simulates hydrogen leak results depending on the hydrogen refueling station components, graphing gas plume dispersion, jet frame temperature and trajectory, and radiative heat flux. In this paper, hydrogen leakage data was extracted from a hydrogen refueling station in Samcheok, Gangwon-do, using HyRAM+ software. A hydrogen leakage simulator was developed using data extracted from HyRAM+. It was implemented as a dashboard that shows the data generated by the simulator using a database and Grafana.

The Study to Find Causes for Measuring Differences of Hydrogen Fillings in Hydrogen Refueling Station (수소충전소의 연료 계량 방법에 따른 계량 오차가 발생하는 원인 고찰)

  • LEE, TAECK HONG;KANG, BYOUNG WOO;LEE, EUN WOUNG;CHUNG, JIN BAE;HONG, SUK JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.32-40
    • /
    • 2018
  • There has been an measuring errors between state of charge (SOC; kg) value and mass flow meter (MFM) value in dispenser for hydrogen refueling station. Finally, we observed average 15.5% weight difference between these two values and the MFM readings show a 15.5% higher readout of the SOC readings. Each car was charged with average 2.66 kg of hydrogen fuel during this period. In the initial charging of the day shows less measuring value than the final charging with the maximum 0.038 kg times number of filling. There is no effects of atmosphere temperature change for the hydrogen filled weight during one full year such as January's cold winters and August's hot summers.

Hydrogen Refueling Stations Improving Safety and Economic Feasibility (안전성과 경제성이 개선된 수소충전소)

  • YunSil Huh;DongHoon Lee;Yongjin Chung;Yongchai Kwon
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.611-618
    • /
    • 2023
  • The purpose of the refueling protocol and the contents of SAE J2601, which is used as the basis for hydrogen vehicles refueling around the world, were investigated, and research contents related to domestic protocols were also investigated. In addition, the components of the hydrogen refueling performance evaluation device developed in Korea and the method for evaluating the performance and safety of hydrogen refueling stations were reviewed. And, the result were analyzed by applying it to the hydrogen refueling stations currently operating in Korea. In addition, an economic feasibility analysis was conducted using data collected from domestic hydrogen refueling stations. In order to secure the safety and economy of a hydrogen refueling station, the protocol must be satisfied, and in order to satisfy the protocol, it is necessary to evaluate whether the refueling temperature, refueling pressure, and refueling flow are controlled within a safe range.

A Study on the Quantitative Risk Assessment of Hydrogen-CNG Complex Refueling Station (수소-CNG 복합충전소 정량적 위험성평가에 관한 연구)

  • Kang, Seung-Kyu;Huh, Yun-Sil
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.1
    • /
    • pp.41-48
    • /
    • 2020
  • This study performed a quantitative risk assessment for hydrogen-CNG complex refueling stations. Individual and societal risks were calculated by deriving accident scenarios that could occur at hydrogen and CNG refueling stations and by considering the frequency of accidents occurring for each scenario. As a result of the risk assessment, societal risk levels were within the acceptable range. However, individual risk has occurred outside the allowable range in some areas. To identify and manage risk components, high risk components were discovered through risk contribution analysis. High risks at the hydrogen-CNG complex refueling station were large leakage from CNG storage containers, compressors, and control panels. The sum of these risks contributed to approximately 88% of the overall risk of the fueling station. Therefore, periodic and intensive safety management should be performed for these high-risk elements.

A study on the safety assessment of Hydrogen refueling system (수소 충전 시스템의 안전성 평가에 관한 연구)

  • Kim, Tae Hun;Oh, Young Dal;Lee, Man Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.167-173
    • /
    • 2014
  • Hydrogen energy is expanding in range for civil use together with development of pollution-free power sources recently, and it is judged that the use of hydrogen will increase more as a part of carbon dioxide reduction measures according to the Climatic Change Convention. Especially, it is thought that the securement of safety of the used dispenser will be the biggest obstacle in the use of high-pressure hydrogen because the hydrogen station is operated in a high pressure. This study found risks in the process and problems on operation by making use of HAZOP(6 kinds), a qualitative safety evaluation technique, and FMEA(5 kinds), a fault mode effect analysis, for the hydrogen charging system at a hydrogen gas station, derived 6 risk factors from HAZOP and 5 risk factors from FMEA, and prepared measures for it.

A Study on Safety Impact Assessment of a Multiple Hydrogen Refueling Station (다차종 동시 충전을 위한 수소 스테이션의 안전 영향 평가 연구)

  • Boo-Seung Kim;Kyu-Jin Han;Seung-Taek Hong;Youngbo Choi
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.85-99
    • /
    • 2024
  • As the proliferation of hydrogen electric vehicles accelerates, there is observed diversification in hydrogen refueling station models. This diversification raises safety concerns for different types of stations. This study conducted a quantitative risk assessment of a multi-vehicle hydrogen station, capable of simultaneously refueling cars, buses, and trucks. Utilizing Gexcon's Effects&Riskcurves Software, scenarios of fire and explosion due to hydrogen leaks were assessed. The study calculated the impact distances from radiative heat and explosion overpressure, and measured risks to nearby buildings and populations. The largest impact distance was from fires and explosions at dispensers and high-pressure storage units. High-pressure storage contributes most significantly to personal and societal risk. The study suggests that conservative safety distances and proper protective measures for these facilities can minimize human and material damage in the event of a hydrogen leak.

TNT Explosion Demonstration and Computational Fluid Dynamics for Safety Verification of Protection Wall in Hydrogen Refueling Station (수소충전소 방호벽 안전성 검증을 위한 TNT 폭발실증 및 전산유동 해석)

  • Yun-Young Yang;Jae-Geun Jo;Woo-Il Park;Hyon Bin Na
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.102-109
    • /
    • 2023
  • In realizing a hydrogen society, it is important to secure the safety of the hydrogen refueling station, which is the facility where consumers can easily meet hydrogen. The hydrogen refueling station consists of compressed gas facilities that store high-pressure hydrogen, and there is a risk that the high-pressure compressed gas facility will rupture due to a fire explosion due to hydrogen leakage in the facility or the influence of surrounding fires. Accordingly, the Korea Gas Safety Corporation is making every effort to find out risk factors from the installation stage, reflect them in the design, and secure safety through legal inspection. In this study, a TNT explosion demonstration test using a protection wall was conducted to confirm the safety effect of the protection wall installed at the hydrogen refueling station, and the empirical test results were compared and verified using FLACS-CFD, a CFD program. As a result of the empirical test and CFD analysis, it was confirmed that the effect of reducing the explosion over-pressure at the rear end of the protection wall decreased from 50% to up to 90% depending on the location, but the effect decreased when it exceeded a certain distance. The results of the empirical test and computer analysis for verifying the safety of the protection wall will be used in proposals for optimizing the protection wall standards in the future.

Effect Analysis of the Pre-Consulting System of Hydrogen Refueling Station for Expanding the Hydrogen Mobility Infrastructure (수소모빌리티 인프라 확대를 위한 수소충전소 사전컨설팅 제도 효과 분석)

  • Lee, Man-Wook;Kim, Sung-Kyu;Tak, Song-Su;Kim, Dae-Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.85-91
    • /
    • 2021
  • In January 2019, the Korean government announced the 「Hydrogen Economy Activation Roadmap」 to be a world-class leading country in Hydrogen economy. Korea has established a strategy that can lead the hydrogen economy with its strong points of 'hydrogen car' and 'fuel cell'. As a part of that, a target of supplying hydrogen vehicle charging stations to 310 by 2022 and 1,200 by 2040 was established. In line with this, Korea Gas Safety Corporation will operate a pre-consulting system of hydrogen vehicle charging station in February 2021 to solve in advance construction delays due to various on-site problems according to safety standards during the construction stage to build a hydrogen refueling station with a sense of speed. This paper is to find out about the pre-consulting system and to analyze its effects.

Accident Risk Consequences Analysis for Operating a Hydrogen Refueling Station in Urban Railway Site (도심 내 철도부지 수소충전소 운영을 위한 사고 위험 영향 분석)

  • Jae Yong Lee;Deokkyu Youn;Chul-Ho Lee;Jaeyoung Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.70-77
    • /
    • 2023
  • In response to climate change, each country is proposing a goal to reduce greenhouse gases in its energy supply and demand plan, and the use of hydrogen gas is a topic that is always prioritized as an energy resource for implementation. A popular way to use this hydrogen gas is the use of hydrogen fuel cell vehicles, and expansion of hydrogen charging stations is essential for using these hydrogen fuel cell vehicles. However, there are several limitations to the expansion of hydrogen refueling stations, the most representative of which is resident acceptance. Most of the hydrogen charging stations currently built in Korea are located in the outskirts with low population density, so the inconvenience to hydrogen fuel cell vehicle users has not been resolved, and as a result, there has been no progress in the spread of hydrogen fuel cell vehicles. In this paper, we analyzed the consequences of accident damage to determine the risks of constructing a hydrogen charging station on a railroad site frequently used by citizens. The target hydrogen charging station site was a railroad depot in Busan, and there are trains, national highways, and commercial facilities around this site. Assuming the worst-case scenario, we would like to consider the safety of the hydrogen refueling station site by analyzing the area affected by the accident and its consequence.

A Study on the Analysis of Risk Factors for Hydrogen Fuel Stations Based on Quantitative Risk Assessment (정량적 위험성평가 기반 수소충전소 위험요소 분석 연구)

  • Lee, Jae Yong;Lee, Jieun;Song, Hyoungwoon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.70-76
    • /
    • 2020
  • In this study, we suggested the direction to lower the risk by analyzing the risk factors for each process for the hydrogen refueling station to be installed in Chungju. HyRAM, one of the quantitative risk assessment tools for hydrogen gas, was used to analyze the hazards. By evaluating the frequency of accidents and consequences for each process, the most dangerous processes and accident factors were presented, and the risk mitigation factors were synthesized. Hydrogen refueling stations are currently in the global infrastructure expansion period, and the lack of accident data could be an alternative to this risk assessment and is expected to be used as a reference for the future expansion of hydrogen refueling stations.