• Title/Summary/Keyword: hydraulic volume

Search Result 431, Processing Time 0.058 seconds

Assessment of Water and Pollutant Mass Balance by Soil Amendment on Infiltration Trench (침투도랑 토양치환의 물순환 및 비점오염물질저감 효과 평가)

  • Jeon, Minsu;Choi, Hyeseon;Kang, Heeman;Kim, Lee-hyung
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.145-152
    • /
    • 2020
  • Highways are characterized by high non-point pollutant emissions due to high traffic volumes and sections that cause abrupt change in driving speed (i.e. rest stations, ticketing office, etc.). Most highways in Korea were constructed with layers that do not allow adequate infiltration. Moreover, non-point pollution reduction facilities were not commonly installed on domestic highways. This study was conducted to evaluate a facility treating highway runoff and develop a cost-effective design for infiltration facilities by using soil amendment techniques. Performing soil amendment increased the hydraulic retention time (HRT) and infiltration rate in the facility by approximately 30% and 20%, respectively. The facility's efficiency of removing non-point pollutants (Total Suspend Soiled (TSS), Chemical Oxygen Demand(COD), Biological Oxygen Demand(BOD), Total Nitrogen (TN) and Total Phosphorus, (TP) were also increased by 20%. Performing soil amendment on areas with low permeability can increase the infiltration rates by improving the storage volume capacity, HRT, and infiltration area. The application of infiltration facilities on areas with low permeability should comply with the guidelines presented in the Ministry of Environment's Standards for installation of non-point pollution reduction facilities. However, soil amendment may be necessary if the soil infiltration rate is less than 13 mm/hr.

Evaluation of Combined Vertical and Horizontal Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment (직렬연결 수직 및 수평 흐름 갈대 제올라이트 인공습지에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.51-59
    • /
    • 2014
  • A sewage was treated using serially combined vertical and horizontal flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of 314 $L/m^2{\cdot}day$. The reed bed depth was 100cm and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite ; 0.5~1mm and 1~3mm in diameter. pH value decreased in vertical bed, while it increased in horizontal bed. But DO concentration in the effluent of both beds was higher than that in the influent. Average removal efficiencies of the entire treatment system were 99.22% SS, 95.56% BOD, 91.02% $COD_{Cr}$, 87.78% $COD_{Mn}$, 45.87% T-N, 99.88% $NH{_4}^+-N$ and 71.17% T-P. Most of T-N in the effluent was $NO{_3}^--N$. However, the concentration of $NO{_2}^--N$ in the effluent was lower than 0.04 mg/L. All removal efficiencies did not show a remarkable seasonal change.

Vertical Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment (수직 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • KSBB Journal
    • /
    • v.22 no.2
    • /
    • pp.102-108
    • /
    • 2007
  • A sewage was treated using a vertical flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of $314L/m^3{\cdot}$day. The filtering height of the reed bed was 100 em and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite: 0.5$\sim$1 mm and 1$\sim$3 mm in diameter. Annual average removal efficiency was 88 89.9%, $COD_{Cr}$ 86.1 %, $COD_{Mn}$ 81.2%, T-N 34.0%, $NH_4^+$-N 97.3% and T-P 34.6%. T-N of effluent was mostly $NO_3^-$-N and the concentration of $NO_2^-$-N in effluent was lower than 0.1 mg/L. All removal efficiencies did not show a remarkable seasonal change. The ranking of phosphorous fractions fixed to the zeolite in column test was Ca-P > Fe-P > reductant soluble Fe-P > occluded P > saloid P > AI-P at all depths of the filter. All phosphorous fractions except for AI-P reduced at deeper filter layer, while their content ratios increased at deeper filter layer. Organic matter content was the highest at the highest layer (0$\sim$5 cm from the top of the filter) and only small differences were observed at the deeper filter layer than 5 em from the top. Organic matter content increased at all depths of the filter with the operating time.

Anaerobic Digestion Efficiency of Remainder from Bacterial Cellulose Production Process using Food Wastes (음식 폐기물을 이용한 박테리아 셀룰로오스 생산 공정 잔류물의 혐기성 소화효율)

  • Jin, Sheng-De;Kim, Seong-Jun
    • KSBB Journal
    • /
    • v.22 no.2
    • /
    • pp.97-101
    • /
    • 2007
  • This study was performed to examine the availability of anaerobic digestion of the remainders caused by bacterial cellulose production process using food wastes. They maybe to be considered as others second pollution sources. Thus, this study was targeted to minimize content of organic material and to obtain more energy in those remnants using two-phase UASB reactor. The working volume of first hydrolysis fermentor was 35 L (total 55 L) and the second methane fermentor was 40 L (total 50 L). The organic loading rate of hydrolysis fermentor was 3 g-VS/L${\cdot}$day and 25,000 ppm of $COD_{cr}$ for methane fermentor. The hydraulic retention time was 18 days for hydrolysis reactor and 33 days for methane reactor. The hydrolysis reactor and methane reactor were performed at 35, 40$^{\circ}C$ respectively. For the efficient stable performance, the composition of organic wastes at each stage was as follow; Food waste with bacterial culture remnants (1 : 1), bacterial cellulose remnants, bacterial cellulose culture remnants with food wastes saccharified solids (1 : 1). When the anaerobic digestion was performed stably at each stage, the COD removal efficiency was 88, 90, 91 % respectively. At this time, methane production rate was 0.26, 0.34, $0.32m^3\;CH_4/kg-COD_{remove}$. As well as the values of anaerobic digestion at third stage were more higher than values of anaerobic digestion using food wastes. It is clearly to say that the food wastes zero-emission system constructed in our lab is more efficient way to treat and reclaim food wastes.

Strain Rate Effect on the Compressive and Tensile Strength of Hooked Steel Fiber and Polyamide Fiber Reinforced Cement Composite (변형 속도에 따른 후크형 강섬유 및 폴리아미드섬유보강 시멘트 복합체의 압축 및 인장강도 특성)

  • Kim, Hong-Seop;Kim, Gyu-Yong;Lee, Sang-Kyu;Son, Min-Jae;Nam, Jeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.76-85
    • /
    • 2017
  • In this study, to evaluate the mechanical properties of fiber-reinforced cement composites by strain rate, hydraulic rapid loading test system was developed. And compressive and tensile strength of the hooked steel fiber and polyamide fiber reinforced cement composite were evaluated. As a result, the compressive strength, strain capacity and elastic modulus were increased with increasing strain rate. The effect of compressive strength by type and volume fraction of fibers was not significant. The dynamic increase factor(DIF) of the compressive strength was higher than that of the CEB-FIP model code 2010 and showed a trend similar to that of ACI-349. The tensile strength and strain capacity were increased with increasing strain rate. The hooked steel fibers were drawn from the matrix. The tensile strength and strain capacity of hooked steel fiber reinforced cement composites were increased as the strain rate increased. The tensile strength and deformation capacity of the fiber reinforced cement composites were increased. And, hooked steel fibers were drawn from the matrix. On the other hand, because the bonding properties of polyamide fiber and matrix is large, polyamide fiber was cut-off with out pullout from matrix. The strain rate effect on the tensile properties of polyamide fiber reinforced cement composites was found to be strongly affected by the tensile strength of the fibers.

Basic Research on Revetments Development of Erosion Protection for Coastline Creation of Hydrophilic Environment by Field Observation (현장관측에 의한 친환경 해안조성을 위한 침식방지 호안공 개발에 관한 기초적 연구)

  • Lee, Jong-Seok;Han, Jae-Myung
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.10
    • /
    • pp.983-993
    • /
    • 2008
  • In recent times, sea level increasing caused by abnormal weather and global warming, sea-sand dredging and complex development causes various kind of erosion damages onto the coastal area in the world. The various types of erosion control and protection methods are applied but there are no signs of fruitful effectiveness. The PC concrete protection block for shore protection structure is practically installed in globally but most of structures in the present day became villainous because of bad accessability. In this study, hydrophilic revetments for control and protection of coastline erosion will be developed in order to make up for a faculty of the shore erosion protection block with better accessibility and excellent protection ability. Experimental measurements were researched to insure for the capacity and facility on reflection coefficient, overtopping volume, and overtopping height characteristics of newly developed shore erosion protection block in model tests. As the result, hydraulic model tests show much excellent than the general step block. Field tests were carried out also to verify through vegetative test on an affinity and construction work test of control-protection on coastline erosion with actual utilization. In the latter case, deposition of sand accumulation occurred in fairly short time at the established reaches and then we can be confirmed to utilize for newly developed block as the revetments for control and protection of coastline erosion.

Effects of the water level reduction and the flow distribution according to change of the side weir location in detention reservoir (홍수조절지 횡월류위어의 위치 변화에 따른 수위 저감 및 유량 분담 효과)

  • Seong, Hoje;Park, Inhwan;Rhee, Dong Sop
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.555-564
    • /
    • 2018
  • The detention reservoir is a hydraulic structure that constructs a levee on the inland of river and sets up side weir in a section of the levee, and this facility stores a part of the flood volume in case of a flood event over a certain scale. In order to optimize the operation of detention reservoir, it is necessary to review the linkage with existing facilities in the river. In this study, the effect of water level reduction and the flow distribution was analyzed according to the location of the side weir in the detention reservoir considering the run-of-the-river gate. Two radial gates were installed in the experimental channel, and the water level in channel and the overflow of weir were measured by moving the location of the side weir upstream from the gate. As a results of experiment, it was confirmed that the water level reduction is more remarkable as the location of the side weir was closer to the gate, and the effect of flow distribution is not greatly changed. When two or more side weirs were operated, it is confirmed that the sufficient storage space was secured and the water level reduction effect with the location of the side weir is not large. In addition, the water level reduction rate according to the location of the side weir was estimated by empirical formula and it is provided as basic data that can be used in the planning of the detention reservoir.

Performance Assessment and Design Evaluation of Bioretention Planter Boxes Treating Urban Stormwater Runoff (도심지역 강우유출수 처리목적 식물재배화분의 성능 및 설계인자 분석)

  • Guerra, Heidi B.;Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.72-79
    • /
    • 2018
  • Two planter boxes were monitored during their initial year of operation to be able to assess their stormwater runoff and pollutant reduction capabilities and investigate on the design factors affecting their performance. One of the planter boxes provided 85-100% runoff volume reduction for rainfall less than 15 mm and rainfall intensities lower than 5 mm/hr. This reduced to 50-64% during higher rainfall intensities and depths of up to 50 mm. Suspended solids, organics, nutrients, and heavy metals were satisfactorily removed at a range of 40-95%. The other planter box, however, did not produce outflow in all the events and allowed total capture of stormwater. The uncertainty regarding the fate of the runoff in that case required an investigation of the planter box's actual drainage and underground conditions which was deemed outside the scope of the study. Nonetheless, several design improvements and retrofits were suggested based on the provisions of current design guidelines to ensure that the hydraulic and water quality goals are achieved without potential damage to nearby structures. Moreover, continuous monitoring data is required to provide more accurate design evaluation and can serve as a guide in the construction of similar facilities in the future.

A study on the dye wastewater treatment by Fenton oxidation process (Fenton 산화공법을 적용한 염색폐수처리 연구)

  • Ahn, June-Shu;Park, Tae-Sool;Cho, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4274-4282
    • /
    • 2011
  • In this study, Fenton reaction was studied for the possibility of applying as advanced treatment and its optimal condition for the removal of refractory organics from the dye wastewater. Fenton reaction was applied to remove refractory organics after the bio-treatment (secondary treatment) inside test laboratory and on-site pilot plant. Wastewater from the secondary treatment was used and its $COD_{Mn}$ was measured as 30~50mg/L. After the Fenton reaction, the optimal condition was found as pH 3~3.5, reaction time 2~2.5hr, chemical input ratio of ($FeCl_2$(33%)/$H_2O_2$(35%)) was 3 : 1. When chemical input ratio of ($FeCl_2$(33%)/$H_2O_2$(35%)) was at its optimal, amount of sludge volume ($SV_{2hr}$) was 21~28%. With pilot plant test, removal rate was heavily influenced by the hydraulic retention time(HRT), and optimum value of HRT was 2.0 hr. When pilot plant($2m^3/d$) was placed on-site and operated continuously, it showed steady and fairly good treatment of COD where COD removal rate was 60~70%, treated water showed below 20mg/L.

Area/free-surface relationship in the river cross-section (하천 횡단면에서 면적-수위 관계)

  • Hwang, Seung-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.258-258
    • /
    • 2019
  • 계산 격자에 기반하여 천수 흐름을 모의할 때, 그 격자에 담긴 물의 양을 정확하게 파악할 필요가 있다. 예를 들어, 초기조건으로 수위가 부여된다면 계산격자의 기하 특성에 맞추어 흐름 변수인 수심이나 흐름 단면적으로 바꾸어야하기 때문이다. 필요에 따라서는 모의 결과를 수위로 보이거나 격자 속 수심을 계산에 사용할 수도 있으므로 그 역변환도 고려되어야 한다. 2차원의 삼각형 계산격자에 대해서는 물의 부피와 수위 관계(volume/free-surface relationship)가 이미 정확(exact)하게 구명되어 있다(Hwang, 2017, J. KWRA). 그런데 1차원 문제의 횡단면에서 흐름 단면적과 수위의 관계(area/free-surface relationship)는 수위로부터 면적 환산에 대해서는 정확하나 그 역변환은 그렇지 않다. 매 시간 단계에서 갱신된 흐름 단면적으로부터 수위를 환산하기 위해 미리 작성된 면적-수위 자료를 이용한 선형 보간이 적용된다(Goodell, 2011, The RAS Solution). 이때, 환산 정확도는 자료의 해상도에 의존된다. 다행히 하천 횡단면 대부분을 채워 흐르는 홍수모의에서는 이 문제가 그리 심각하지는 않다. 심지어 수위가 복단면 저수로 턱에 걸쳐있어 흐름단면적이 급변하는 경우에도 환산 수위의 정확도는 크게 훼손되지 않는다. 그러나 미미한 환산 오차일지라도 그로 인해 수위가 저수로 턱을 넘거나 그보다 작을 수 있다. 이 경우, 홍수터의 잠김여부에 따라 수면폭(top width)이 실제 계산 결과에 비해 크게 달라질 수밖에 없다. 수면폭 오차는 그것을 이용하여 결정되는 수리 수심(hydraulic depth)이나 평균 하상고(mean bed level)의 산정에도 전파된다. 이 연구에서는 하천 횡단면에서 수위와 흐름 단면적 사이의 환산 정확도를 크게 높일 수 있는 기법을 제시하였다. 먼저 하천 횡단면에서 주어진 수위에 대해 흐름 단면적을 산정할 수 있는 알고리듬을 보였다. 또한, 횡단면에서 수위와 흐름 단면적의 관계가 단조 증가 함수(monotonically increasing function)임에 착안하여 그 역변환에 대해 해 찾기(root finding) 방법의 하나인 Brent 기법을 적용하였다. 이 기법은 주어진 구간에서 도함수가 알려져 있지 않은 경우에 대해서도 효과적으로 해를 찾을 수 있는 것으로 알려져 있다(Press et al., 2002, Numerical Recipes in C, 2nd Ed.). 내성천 하류 수계의 333개 단면에서 수면폭에 대한 상대 오차를 살펴보면, 선형 보간에 의한 기존 방법으로는 면적-수위 자료의 수가 1,000개가 되어도 그 최대치가 1% 이내에 들지 않은 반면, 이 연구에서 제시한 기법으로 면적-수위 자료 없이도 1% 이내로 줄어드는 것을 확인하였다. 다만, 반복 계산에 의한 계산 시간의 증대를 피할 수 없다. 미리 작성된 면적-수위 자료를 이용하면 계산 비용을 줄일 수 있으며, 약 35개의 구간으로 나누었을 때 비용 대비오차가 적절하였다. 이 연구는 한국건설기술연구원(주요사업 과제번호: 20190116-001)의 지원에 의한 것이다.

  • PDF