• Title/Summary/Keyword: hydraulic volume

Search Result 434, Processing Time 0.037 seconds

Effect of Corrected Hydrostatic Pressure in Shallow-Water Flow over Large Slope (대경사를 지나는 천수 흐름에서 수정된 정수압의 효과)

  • Hwang, Seung-Yong
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.12
    • /
    • pp.1177-1185
    • /
    • 2014
  • This study suggests a new hydrostatic pressure distribution corrected for nonuniform flow over a channel of large slope. For analyzing shallow-water flows over large slope accurately, it is developed a finite-volume model incorporating the pressure distribution to the shallow water equations. Traveling speed of the hydraulic jump downstream a parabolic bump in the drain case is quite reduced by the weakened bottom gradient source term in the model with the pressure correction. In simulating the dam-break flow over a triangular sill, it is identified that the model with pressure correction could capture the water surface by the digital imaging measurements more than the model without that. Due to the pressure correction decreasing the reflected flows on and increasing overflows over the sill, there are good agreements in the experiment and the simulation with that. Therefore, this model is expected to be applied to such practical problems as flows in the spillway of dam or run-up on the beach.

Study of Stay Vanes Vortex-Induced Vibrations with different Trailing-Edge Profiles Using CFD

  • Neto, Alexandre D'Agostini;Saltara, Fabio
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.363-374
    • /
    • 2009
  • The 2D flow around 13 similar stay-vane profiles with different trailing edge geometries is investigated to determinate the main characteristics of the excitation forces for each one of them and their respective dynamic behaviors when modeled as a free-oscillating system. The main goal is avoid problems with cracks of hydraulic turbines components. A stay vane profile with a history of cracks was selected as the basis for this work. The commercial finite-volume code $FLUENT^{(R)}$ was employed in the simulations of the stationary profiles and, then, modified to take into account the transversal motion of elastically mounted profiles with equivalent structural stiffness and damping. The k-$\omega$ SST turbulence model is employed in all simulations and a deforming mesh technique used for models with profile motion. The static-model simulations were carried out for each one of the 13 geometries using a constant far field flow velocity value in order to determine the lift force oscillating frequency and amplitude as a function of the geometry. The free-oscillating stay-vane simulations were run with a low mass-damping parameter ($m^*{\xi}=0.0072$) and a single mean flow velocity value (5m/s). The structural bending stiffness of the stay-vane is defined by the Reduced Velocity parameter (Vr). The dynamic analyses were divided into two sets. The first set of simulations was carried out only for one profile with $2{\leq}Vr{\leq}12$. The second set of simulations focused on determining the behavior of each one of the 13 profiles in resonance.

A Study on the Practical Operation of a Farm-scale Two-phase Anaerobic Digester for the Treatment of Swine Manure (돼지분뇨 처리를 위한 Farm-scale Two-phase Anaerobic Digester의 실증운영에 관한 연구)

  • 백인규;이상락;안정제;권윤정;맹원재
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.73-81
    • /
    • 2000
  • A two-phase anaerobic digestion system for the treatment of swine waste was constructed in a commercial hog farm. The digester system was composed of 4 major units; slurry storage pit, acidogenic digester, methanogenic digester and sedimentation pit. A biogas boiler unit was also attached to maintain the digester temperature of 37$^{\circ}C$. Substrate lading was made with 2hr-interval by pumping about 2.1$m^3$ of slurry type swine waste from the slurry pit into the acidogenic digester, which corresponds to hydraulic retention time of 4 days for the acidogenic digester and of 11 days for the methanogenic digester. Digester temperature were well maintained as the set temperature of 37$^{\circ}C$ in the methanogenic digester, while the temperature in the acidogenic digester showed around 34$^{\circ}C$. pH also showed a steady-state results of 7.3 in the acidogenic digester and of 7.6 in the methanogenic digester during the operation period. Average biogas production rate was 0.66$m^3$/$m^3$ digester volume. Reduction rate of total solid and volatile solid were 42.8% and 5.8%, respectively. Total nitrogen and ammonia nitrogen were not reduced during the anaerobic fermentation, however, most of VFAs seemed to be converted to the biogas,. These fermentation performance data may suggest that he newly developed a two-phase anaerobic digester for the swine waste treatment worked so successfully.

  • PDF

Development study of ground water management system making use of GIS ( Well analysis program, connection program of ground water modeling ) (GIS를 이용한 지하수관리시스템 개발 연구 (관정분석 프로그램, 지하수모델링 연계프로그램))

  • 이병호;김양빈;설민구;송양권;송무영
    • Proceedings of the KSEG Conference
    • /
    • 2002.04a
    • /
    • pp.235-248
    • /
    • 2002
  • Ground water development skill growth and life circumstances improvement increase ground water use. So managerial difficulties and various problems about ground water occur. Poor ground water management organization, lack of management person, thoughtless development add ground water pollution and lack of water volume. And local excessive developments or abandoned well occur. This paper presents ground water management system model making use of GIS and helps effective management by realizing necessary analysis functions in ground water management system and ground management methods. Local information of ground water recorded and development data, site examination data made D/B. And linearment analysis data making use of a satellite image data, hydraulic test data, the quality of water examination data, these local characteristic values made out thematic maps and making use of these data can form elementary data of ground water modeling It makes easy to understand environmental development conditions and pollution source conditions about new ground water development location, linearment growth, DRASTIC, the quality of water examination. Ground water management system making use of these functions can choose right location of ground water.

  • PDF

EXPERIMENTAL INVESTIGATIONS RELEVANT FOR HYDROGEN AND FISSION PRODUCT ISSUES RAISED BY THE FUKUSHIMA ACCIDENT

  • GUPTA, SANJEEV
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.11-25
    • /
    • 2015
  • The accident at Japan's Fukushima Daiichi nuclear power plant in March 2011, caused by an earthquake and a subsequent tsunami, resulted in a failure of the power systems that are needed to cool the reactors at the plant. The accident progression in the absence of heat removal systems caused Units 1-3 to undergo fuel melting. Containment pressurization and hydrogen explosions ultimately resulted in the escape of radioactivity from reactor containments into the atmosphere and ocean. Problems in containment venting operation, leakage from primary containment boundary to the reactor building, improper functioning of standby gas treatment system (SGTS), unmitigated hydrogen accumulation in the reactor building were identified as some of the reasons those added-up in the severity of the accident. The Fukushima accident not only initiated worldwide demand for installation of adequate control and mitigation measures to minimize the potential source term to the environment but also advocated assessment of the existing mitigation systems performance behavior under a wide range of postulated accident scenarios. The uncertainty in estimating the released fraction of the radionuclides due to the Fukushima accident also underlined the need for comprehensive understanding of fission product behavior as a function of the thermal hydraulic conditions and the type of gaseous, aqueous, and solid materials available for interaction, e.g., gas components, decontamination paint, aerosols, and water pools. In the light of the Fukushima accident, additional experimental needs identified for hydrogen and fission product issues need to be investigated in an integrated and optimized way. Additionally, as more and more passive safety systems, such as passive autocatalytic recombiners and filtered containment venting systems are being retrofitted in current reactors and also planned for future reactors, identified hydrogen and fission product issues will need to be coupled with the operation of passive safety systems in phenomena oriented and coupled effects experiments. In the present paper, potential hydrogen and fission product issues raised by the Fukushima accident are discussed. The discussion focuses on hydrogen and fission product behavior inside nuclear power plant containments under severe accident conditions. The relevant experimental investigations conducted in the technical scale containment THAI (thermal hydraulics, hydrogen, aerosols, and iodine) test facility (9.2 m high, 3.2 m in diameter, and $60m^3$ volume) are discussed in the light of the Fukushima accident.

Metabolic Pathways of Hydrogen Production in Fermentative Acidogenic Microflora

  • Zhang, Liguo;Li, Jianzheng;Ban, Qiaoying;He, Junguo;Jha, Ajay Kumar
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.5
    • /
    • pp.668-673
    • /
    • 2012
  • Biohydrogen production from organic wastewater by anaerobically activated sludge fermentation has already been extensively investigated, and it is known that hydrogen can be produced by glucose fermentation through three metabolic pathways, including the oxidative decarboxylation of pyruvic acid to acetyl-CoA, oxidation of NADH to $NAD^+$, and acetogenesis by hydrogen-producing acetogens. However, the exact or dominant pathways of hydrogen production in the anaerobically activated sludge fermentation process have not yet been identified. Thus, a continuous stirred-tank reactor (CSTR) was introduced and a specifically acclimated acidogenic fermentative microflora obtained under certain operation conditions. The hydrogen production activity and potential hydrogen-producing pathways in the acidogenic fermentative microflora were then investigated using batch cultures in Erlenmeyer flasks with a working volume of 500 ml. Based on an initial glucose concentration of 10 g/l, pH 6.0, and a biomass of 1.01 g/l of a mixed liquid volatile suspended solid (MLVSS), 247.7 ml of hydrogen was obtained after a 68 h cultivation period at $35{\pm}1^{\circ}C$. Further tests indicated that 69% of the hydrogen was produced from the oxidative decarboxylation of pyruvic acid, whereas the remaining 31% was from the oxidation of NADH to $NAD^+$. There were no hydrogen-producing acetogens or they were unable to work effectively in the anaerobically activated sludge with a hydraulic retention time (HRT) of less than 8 h.

Study on Surface Vortices in Pump Sump

  • Long, Ngo Ich;Shin, Byeong Rog;Doh, Deog-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.60-66
    • /
    • 2012
  • One of commonly physical phenomena encountered in pump sump systems in which its significant influence to the hydraulic performance of pump system plays an important role in the field of fluid engineering, is the appearance of free surface and submerged vortices. In this paper, a study of the vortices behavior and their formative mechanism of asymmetry is considered in this paper by using numerical approach. The Reynolds-Averaged Navier-Stokes (RANS) equations and k-omega Shear Stress Transport turbulence model used to describe the properties of turbulent flows, in company with VOF multiphase model, are implemented by Fluent code with multi-block structured grid system. In the numerical simulation, the calculated elevation of air-water interface and vortex core contours are used to classify visually surface vortices as well as submerged vortices. It is shown that the free surface vortex is identified by the concavity of liquid region from the free surface and swirling flow at that own plane. To investigate the distinctive behavior of these vortices corresponding to each given flow rate at the same water level, some numerical testing of them are considered here in such a manner that the flow pattern of surface vortex are obtained similarly to the obtained results from experiment. Furthermore, the influence due to the change of grid refinement and the variation of depth of the concavity are also considered in this paper. From that, these influential factors will be implemented to design a good pump sump with higher performance in the future.

Characteristics of Denitrification from Municipal Wastewater Treatment using a Combined Fixed Film Reactor (CFFR) Process (복합생물막 반응기를 이용한 하수처리시 탈질화 특성)

  • 이종현;남해욱;김영규;박태주
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • A new biological nutrient removal system combining $A^2/O$ process with fixed film was developed in this work and the characteristics of denitrification were especially investigated in the combined fixed film reactor(CFFR). Media was added in the anaerobic, anoxic and aerobic reactors, respectively. Tests were made to establish the effluent level of $NO_x-N$, COD, DO and nitrite effects on $NO_x-N$ removal in the CFFR by decreasing hydraulic retention time (HRT) from 10.0 to 3.5 hours and by increasing internal recycle ratio form 0% to 200%. The influent was synthesized to levels similar to the average influent of municipal wastewater treatment plants in Korea. SARAN media with a porosity of 96.3% was packed 40% / 130% / 25% based on its reactor volume, respectively. It was found that COD rarely limited dentrification in the anoxic reactor because of high $C/NO_x/-N$ ratio in the anoxic reactor, while DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent inhibited denitrification in the anoxic reactor. It was proved that the critical points of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent were 0.15mg/L and 10%, respectively. As the internal recycle ratio increased, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent increased. Especially, at the condition of internal recycle ratio, 200%, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent exceeded the critical points of 0.15mg/L and 10%, respectively. Then, denitrification efficiency considerably decreased. Consequently, it was represented that the control of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent can assure effective denitrification.

  • PDF

Effect of Serpentine as Soil Conditioner on Growth of Turfgrass (토양 개량재로서 사문석이 잔디의 생육에 미치는 영향)

  • 태현숙;고석구;김용선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.3
    • /
    • pp.86-93
    • /
    • 2002
  • The objectives of this research were to investigate the effect of serpentine as a new soil conditioner for growth of turfgrass. To achieve the goal, pure sand or mixtures of sand and serpentine with various ratios were tested for soil physical properties and the growth effects of perennial ryegrass and zoysiagrass growth were compared. Major results of this research are summarized as follows; 1) Hydraulic conductivity of 10~30% serpentine mixtures were observed within the range of 1010~901mm/h which is good for USGA recommendation. Experimental results of pH and EC for various mixtures indicated that the 10% serpentine mixture was the most suitable for turfgrass growth. 2) Perennial ryegass treated with 10% serpentine mixture showed the highest visual quality(p<0.01) among all treatments. And serpentine treatment was more effective to improve visual quality of perennial ryegrass than that of zoysiagrass. The treatment of 10% serpentine had better visual qualities than that of 20% in both of zoysiagrass and perennial ryegrass. Treatment with the right amount of serpentine extends green period for one to two weeks during early winter in both zoysiagrass and perennial ryegrass. 3) In perennial ryegrass, the treatment of 10% serpentine resulted in an increase of total dry weight compare with those of zeolite or barley stone, and also dramatically promoted the dry weight by 15% compared with sand 100%(control). Total dry weight of zoysiagrass treated with 10% serpentine was 9% higher than that of san. These results indicated that serpentine can be a good soil conditioner for both zoysiagrass and perennial ryegrass when it is blended with sand within a range of 10 to 20% by volume.

Experimental Studies on Thermal-Fluidic Characteristics of Carbon Dioxide During Heating Process in the Near-Critical Region for Single Channel (단일채널 내 임계영역 이산화탄소 가열과정의 열유동 특성에 관한 실험적 연구)

  • Choi, Hyunwoo;Shin, Jeong-Heon;Choi, Jun Seok;Yoon, Seok Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.8
    • /
    • pp.408-418
    • /
    • 2017
  • Supercritical carbon dioxide ($sCO_2$) power system is emerging technology because of its high cycle efficiency and compactness. Meanwhile, PCHE (Printed Circuit Heat Exchanger) is gaining attention in $sCO_2$ power system technology because PCHE with high pressure-resistance and larger heat transfer surface per unit volume is fundamentally needed. Thermo-fluidic characteristics of $sCO_2$ in the micro channel of PCHE should be investigated. In this study, heat transfer characteristics of $sCO_2$ of various inlet conditions and cross-sectional shapes of single micro channel were investigated experimentally. Experiment was conducted at supercritical state of higher than critical temperature and pressure. Test sections were made of copper and hydraulic diameter was 1 mm. Convective heat transfer coefficients were measured according to each interval of the channel and pressure drop was also measured. Convective heat transfer coefficients from experimental data were compared with existing correlation. In this study, using measured data, a new empirical correlation to predict near critical region heat transfer coefficient is developed and suggested. Test results of single channel will be used for design of PCHE.