• Title/Summary/Keyword: hydraulic efficiency in clearwell

Search Result 8, Processing Time 0.067 seconds

The Effect of Dead Zone on Hydraulic Efficiency in Clearwell (정수지내 사류지역이 수리학적 효율에 미치는 영향 연구)

  • Lee, Seungjae;Shin, Eunher;Kim, Sunghoon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.177-185
    • /
    • 2007
  • Hydraulic efficiency($T_{10}/T$) in clearwell is often estimated by L/W ratio. However, this estimation is not accurate because other factors which give an effect on hydraulic efficiency such as shape of basin, diffuser wall and intra-basin is ignored. Therefore, in this research, hydraulic efficiency is predicted by the quantitative analysis of dead zone using CFD simulation in a pilot scale clearwell. The results show that the reason why higher L/W ratio increase the hydraulic efficiency is to decrease the dead zone of linear region which is located between baffles. Diffuser wall or intra-basin also affects on hydraulic efficiency with this process. Also, we conclude that hydraulic efficiency can not be reached to 0.8 or higher.

Case study comparisons of computational fluid dynamics modeling versus tracer test to evaluate the hydraulic efficiency of clearwell (정수지 내 추적자 실험과 CFD(전산유체역학)의 상관관계 분석)

  • Kim, Tae-Kyun;Choi, Young-June;Jo, Young-Mahn
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.635-642
    • /
    • 2011
  • Hydraulic efficiency was a vital component in evaluating the disinfection capability of clearwell. Current practice evaluates these system based on the tracer test only. In this paper, CFD(Computational Fluid Dynamics) was applied on the clearwell for alternating or supplementing the tracer test. The baffle factor derived from the CFD modeling closely matched the values obtained from full scale tracer testing. And, for suggesting proper numerical model in clearwell; the turbulence model, discretization scheme, convergence criteria were investigated through separate simulation runs. The model validation was conducted by comparing the simulated data with experimental data. In the turbulence model, the realizable ${\kappa}-{\varepsilon}$ model and the standard ${\kappa}-{\varepsilon}$ model were found to be more appropriate than RNG ${\kappa}-{\varepsilon}$ model. The residuals of convergence criteria should be used as not $10^{-3}$ but $10^{-4}$ or $10^{-5}$. In discretization scheme, the difference of simulated values in 1st, 2nd, 3rd upwind scheme was found to be insignificant. Moreover, the result of this study suggest that CFD modeling can be a reliable alternative to tracer testing for evaluating the hydraulic efficiency.

Case study on Remodeling Clearwell Hydraulic Structure using Transient CFD Simulation Technique (Transient CFD 모사기법을 이용한 정수지 최적설계 사례연구)

  • Kim, Seon-Jin;Kim, Seong-Su;Park, No-Suk;Cha, Min-Whan;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.425-432
    • /
    • 2010
  • From the results of tracer test for the existing clearwell in Y water treatment plant, $T_{10}$ and T10/T were calculated as 150 min and 0.24, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by $T_{10}$ and $T_{10}$/T, and disinfection performance. In this study, using transient CFD(Computational Fluid Dynamics) simulation technique, tracer tests on dynamic condition for the suggested schemes were simulated. From the results of simulation, it was revealed that 8~6 baffles are necessary to guarantee the disinfection ability in the existing clearwell. Also, installing orifice baffle in the vicinity of inlet could increase plug flow fraction within clearwell.

Effect of Shape and Flow Rate on T10 in Clearwell (정수지의 형상과 유입 유량이 T10에 미치는 영향 연구)

  • Shin, Eun-Her;Kim, Sung-Hoon;Park, Hee-Kyung;Ahn, Jae-Chan;Choi, Jae-Ho;Choi, Young-June
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.819-826
    • /
    • 2005
  • To guarantee the disinfection ability in clearwell, a value of CT is considered where C[mg/l] is disinfectant residual at the exit of clearwell and T[min] means $T_{10}$, the contact time when 10% of tracer is out of clearwell after introducing the tracer at the inlet. To meet a CT value required, increasing the C value is not recommended because high C value can increase potential of producing disinfection by product like THMs. Increasing the hydraulic efficiency surrogated by $T_{10}$ is thus an option widely recommended. Right now, it is widely adopted estimating $T_{10}$ considering LW ratio only due to the suggestions of previous researches. The authors think however there are other factors to consider including shape, flow rate, configuration of inlet and outlet, and the existence of intra basin. This study is initiated to closely look at the effects of two factor on hydraulic efficiency. The factors are shape and inlet flow velocity, i.e., inflow. For that, computational fluid dynamics (CFD) model is developed and pilot test is also carried out. The results show that at a L/W ratio, disinfection ability is overestimated with larger length in shape and higher inlet flow velocity. This suggests that in determining $T_{10}$, the shapes of clearwell and inlet flow velocity should also be considered as well as L/W ratio.

Internal Short-circuiting Estimation in Clearwell : Part A. Improving T10/T Using Intra Basin and Diffuser Wall by Applying ISEM to Field (정수지 내부 단락류 발생 평가 : Part A. 정수장 내부 단락류 분석을 통한 장폭비와 형태가 T10/T 값에 미치는 영향 연구)

  • Shin, Eunher;Lee, Seungjae;Kim, Sunghoon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • Disinfection is a basic and effective microorganism inactivation method and historically contributed a decrease in waterborne diseases. To guarantee the disinfection ability, improving T in CT value is important. Many indexes are used to estimate the hydraulic efficiency, however, these are black-box analysis. Therefore it is need to develope new estimation method. In this study, internal short-circuiting estimation method (ISEM) is developed using CFD and we inquire into the factor which causes increase of $T_{10}/T$ value as LW ratio increases. And the effect of shape on the relation of LW ratio and $T_{10}/T$ is analyzed. As LW ratio increases, internal short-circuiting index (ISI) of influent and effluent zone is rapidly reduced and recirculation and dead zone are reduced in channel zone. Therefore, as the $T_{10}/T$ value converges maximum value, ISI curve is changed from "V" shape to "U" shape and hydraulic efficiency is improved especially in downstream portion of clearwell. The less the shape ratio(width/length of clearwell) is the less the $T_{10}/T$ value is at a same LW ratio because the portion of turning zone increases as shape ration decreases, therefore more boundary separation is generated.

Internal Short-circuiting Estimation in Clearwell : Part B. Improving T10/T Using Intra Basin and Diffuser Wall by Applying ISEM to Field (정수지 내부 단락류 발생 평가 : Part B. 내부 단락류 평가 방법의 현장 적용을 통한 내부 도류벽과 정류벽을 이용한 T10/T 증가분석)

  • Shin, Eunher;Lee, Seungjae;Kim, Sunghoon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.113-120
    • /
    • 2008
  • A large majority of clearwell must be modified with maintaining the present baffles since they were underground built with the material like concrete. Therefore it is unreasonable to apply the previous research in clearwell modification which is studied with the assumption that distance between baffles is constant. In this study, internal short-circuiting estimation method (ISEM), which has the advantage of being applied at any condition, is applied to evaluate modification of A clearwell and modify B and C clerwell which have unusual characteristics. After analyzing the hydraulic efficiency at current state, modifications, where baffles, intra basins and diffuser walls are additionally installed, are considered and evaluate using ISEM. And the effect of intra basin and diffuser wall on $T_{10}/T$ is estimated and application feasibility of ISEM is evaluated. The improvement of intra basins is almost same with that of baffles. Also, short-circuiting in effluent zone can be reduced with the same level of channel zone if intra basin is added in effluent zone. However, effect range is restricted to the next channel zone. Diffuser wall can obtain the lower ISI than minimum ISI of cases where baffles and intra basins are installed. Therefore, additional improvement of $T_{10}/T$ value can be expected after $T_{10}/T$ value converges maximum only using baffles

Case study on Hydraulic characteristics within Chlorine Contactors in Series (염소 접촉조 직렬 연결시 수리흐름 특성에 관한 연구)

  • Kang, Tea-Hun;Chae, Seon-Ha;Kim, Seong-Su;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.497-502
    • /
    • 2011
  • In order to examine the effects of combination of plug flow reactors in series on hydraulic characteristics, comparative tracer tests were conducted for the cases of the existing clear well and clear wells combined in series. From the results of tests, $T_{10}$/T within existing clear well was 0.62~0.68 depending on inlet flowrate, and that in the case of combination in series was 0.69~0.78. While it would be minor improvement in contact efficiency, it would be appropriate to combine two clearwell with pipe in series for expansion.

Evaluation of Economic L/W Ratio and the Best Shape of Baffle in Clearwell by Using CFD (전산유체를 활용한 정수지 최적 도류벽 형태 및 경제적인 장폭비 산정)

  • Cho, Young-Man;Roh, Jae-Soon;Bin, Jae-Hoon;Kim, Tae-Kyun;Choi, Young-June
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.6
    • /
    • pp.432-438
    • /
    • 2011
  • We need to make the standard of the best baffle shape and L/W ratio of clearwell due to insufficient disinfection in short L/W ratio and uneconomic design in long L/W ratio. The objectives of this research were to evaluate the best shape of baffle and economic L/W ratio in the all sorts of shape and size by using computational fluid dynamics. In the results of this research, the baffle with smaller number of turning flow is more beneficial for hydraulic efficiency. So, even if the same shape and structure, baffle should be designed as smaller number in turning flow. The best shape of baffle is ZigZag type (model 2) and the worst shape is Distributed types (model 4). The ZigZag type can reduce number of baffle about 67% than that of the Distributed types. In the ZigZag type, economic L/W ratio is 30~50. If L/W ratio exceed over 50, it is not economic because construction costs greatly increase and an increasing rate of $T_{10}/T$ is very small.