Browse > Article

Case study on Hydraulic characteristics within Chlorine Contactors in Series  

Kang, Tea-Hun (한국수자원공사)
Chae, Seon-Ha (한국수자원공사)
Kim, Seong-Su (한국수자원공사)
Wang, Chang-Keun (충남대학교 환경공학과)
Publication Information
Journal of Korean Society of Water and Wastewater / v.25, no.4, 2011 , pp. 497-502 More about this Journal
Abstract
In order to examine the effects of combination of plug flow reactors in series on hydraulic characteristics, comparative tracer tests were conducted for the cases of the existing clear well and clear wells combined in series. From the results of tests, $T_{10}$/T within existing clear well was 0.62~0.68 depending on inlet flowrate, and that in the case of combination in series was 0.69~0.78. While it would be minor improvement in contact efficiency, it would be appropriate to combine two clearwell with pipe in series for expansion.
Keywords
chlorine contactor; series; tracer test; hydraulic characteristics;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 김선진, 김성수, 박노석, 차민환, 왕창근 (2010) "Transient CFD 모사기법을 이용한 정수지 최적설계 사례연구" 상하수도학회지, Vol.24, No.4, pp.425-432.
2 박현오, 박노석, 차민환, 김사동, 원찬희 (2010) "유공벽을 이용한 우류식 염소접촉조 사류 저감 방안 연구" 상하수도학회지, Vol.24, No.5, pp.519-525.
3 신은허, 이승재, 김성훈, 박희경, (2008) "정수지 내부 단락류 발생평가 :Part A. 정수장 내부 단락류 분석을 통한 장폭비와 형태가 $T_{10}$/T값에 미치는 영향 연구", 상하수도학회지, Vol.22, No.2, pp.105-112.
4 신은허, 이승재, 김성훈, 박희경, (2008) "정수지 내부 단락류 발생평가 :Part B. 내부 단락류 평가 방법의 현장 적용을 통한 내부 도류벽과 정류벽을 이용한 $T_{10}$/T증가 분석", 상하수도학회지, Vol.22, No.1, pp.113-120.
5 신은허, 김성훈, 박희경, 안재찬, 최재호, 최영준, (2005) "정수지의 형상과 유입유량이 T10에 미치는 영향연구" 상하수도학회지, Vol.19, No.6, pp.819-826.
6 이승재, 신은허, 김성훈, 박희경, (2007) "정수지내 사류지역이 수리학적 효율에 미치는 영향 연구" 상하수도학회지, Vol.21, No.2, pp.177-185.
7 한국상하수도협회, 상수도시설 유지관리매뉴얼, 2007
8 환경부, 2010, 상수도시설기준
9 Bishop M.M., Morgan J.M., Cornell B., and Jamison D.K. (1993) "Improving the Disinfection Time of Water Plant Clearwell", Journal of AWWA, 85(3), pp.68-75.
10 Clark. M.M., Ducoste J. and Burns C. (1999) Improving Clearwell Design for CT Compliance, AWWARF and AWWA
11 Currie, I. G., (1993) Fundamental mechanics of fluids, McGraw-Hill, New York.
12 Hannoun I.A. and Bouls F. (1997) "Optimizing distribution storage water quality :A hydrodynamic approach", Appl. Math. Modelling, 21, pp.495-502.   DOI   ScienceOn
13 Hannoun I.A., Bouls F. and List J. (1998) "Using hydraulic modeling to optimize contact time", Journal of AWWA, 90(8), pp.77-87   DOI
14 Hudson, H. E. Jr (1981) Water clarification Process, Practical Design, and Evaluation, Van Nostrand Reinhold, New York.
15 Kawamura, S. (2000) Integrated Design of Water Treatment Facilities, 5th ed., John Wiley&Sons, New York
16 Lee Seungjae, Shin Eunher, Kim Sunghoon and Park Heekyung (2006) "Improving Hydraulic Efficiency of Clearwell Using CFD Simulation", 15th Joint KKNN Symposium, Kyoto, Japan.
17 Shilton A. and Harrison J. (2003) "Development of guidelines for improved hydraulic design of waste stabilization ponds" Water Science and Technology, 48(2), pp.173-180
18 Teefy, S.M., and Singer, P.C. (1990) "Performance and Analysis of Tracer Tests to Determine Compliance of a Disinfection Scheme with the SWTR", Journal of AWWA, Vol.82, No.12, pp.88-98.   DOI