• 제목/요약/키워드: hydraulic actuator

검색결과 318건 처리시간 0.033초

절자 비례 밸브를 갖는 펌프의 퍼지-동력제어기 설계 (Design of Fuzzy-Power Controller for a Pump with Electric Proportional Valve)

  • 전순용
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.441-447
    • /
    • 1998
  • Motivated by a recent work, a fuzzy-power-controller(FPC) is designed for the relieving-horsepower control of output variable pump with electrical proportional valve and actually implemented on the industrial excavator. In order to calculate the output power of pump with input of FPC, a linear discrete time model of load system to pump is obtained and the result is applied to control the engine-pump coupled system by software without pressure and flow sensor. The FPC controls the engine and pump coupled system by relieving horsepower control according to the change of load and the running conditions in relieving horsepower control are selected by fuzzy inference engine. A case study is peformed through the construction of the control device and installation on the excavator. It shows that the relieving-horsepower control system with the FPC, as suggested in this paper, is superior to the conventional PID controllers. And also, the excavator, with the FPC, shows that the power-loss of the coupled system is reduced and the running speed of the hydraulic actuator is enhanced.

  • PDF

3 자유도 굴착기 부속 시스템의 기구학적 최적 설계와 기구학/동력학 성능 해석 (Kinematic optimal design and analysis of kinematic/dynamic performances of a 3 degree-of-freedom excavator subsystem)

  • 김희국;한동영;이병주
    • 제어로봇시스템학회논문지
    • /
    • 제3권4호
    • /
    • pp.422-434
    • /
    • 1997
  • In this paper, a two-stage kinematic optimal design for a 3 degree of-freedom (DOF) excavator subsystem, which consists of boom, arm and bucket, is performed. The objective of the first stage is to find the optimal parameters of the joint-actuating mechanisms which maximize the force-torque transmission ratio between the hydraulic actuator and the rotating joint. The objective of the second stage is to find the optimal link parameters which maximize the isotropic characteristic of the excavator subsystem throughout the workspace. It is illustrated that kinematic/dynamic performances of the kinematically optimized excavator subsystem have improved compared to those of original HE280 excavator, with respect to three performance indices such as maximum load handling capacity, maximum velocity capability, and acceleration capability.

  • PDF

고등훈련기 전기체 정적시험을 위한 여압시험 (Pressurization Test for Full-scale Static Test of T-50 Aircraft)

  • 심재열;김태욱;송재창;황귀철;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1384-1387
    • /
    • 2003
  • Pressurization test is usually required in aircraft full-scale static test. There are several test conditions including pressurization of cockpit, fuselage fuel tank, air inlet duct for T-50 full-scale static test. In this paper, the test conditions, equipment, piping analysis for the pressurization test are introduced. Tank simulation test is performed to verify the validity of piping analysis and to find good tuning parameters for the pressurization channel in the servo controller. Several test setup for pressurization of T-50 test is introduced. Test article volume is filled by form, $60%{\sim}80%$ volume is reduced for the T-50 full-scale static test. Pressurization system is connected to servo controller which also controls hydraulic actuator. Load and pressure control is synchronized by using the same servo controller during T-50 test. Typical control result for pressurization test condition is shown. Pressurization tests of T-50 full-scale static test was completed successfully.

  • PDF

전기체 구조시험의 덤프밸브 조절절차 개발; (Setup Procedure of Dump Valve for Full-Scale Airframe Test)

  • 김성찬;김성준;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1252-1257
    • /
    • 2003
  • This paper present a procedure of meter-out flow control method for dump valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

다축 시뮬레이터의 구동 소프트웨어 개발 및 보정에 관한 연구 (A Study on Operating Software Development and Calibration of Multi-Axis Simulation)

  • 정상화;류신호;신형성;김상석;김종태;박용래
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.141-141
    • /
    • 2000
  • In the recent day, fatigue life prediction techniques play a major role in the design of components in th ground vehicle industry. Full scale durability testing in the laboratory is an essential of any fatigue life evaluation of components or structure of the automotive vehicle. Component testing is particularly important in today's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, multi-axis durability testing simulator is used to car교 out the fatigue test. In this paper, the operation software for simultaneously driving 3-axis simulator is developed and the real-time signals of input-output data are displayed in window of PC. Moreover, the displacements and the loads of 3-axis actuators are calibrated separately and the operating characteristics of the actuators are evaluated.

  • PDF

강인 포화 제어기의 안정성에 관한 실험적 연구 (Experimental Study on Stability of Robust Saturation Controller)

  • 임채욱;문석준;박영진;박윤식
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.207-213
    • /
    • 2006
  • In our previous research, we proposed a robust saturation controller which involves both control input saturation and structured real parameter uncertainties. This controller can analytically prescribed the upper and lower bounds of parameter uncertainties, and guarantee the closed-loop robust stability of the system in the presence of actuator's saturation. And the availability and the effectiveness of the proposed robust saturation controller were verified through numerical simulations. In this paper, we verify the robust stability of this controller through experimental tests. Expecially, we show unstable cases of other controllers in comparison with this controller. Experimental tests are carried out in the laboratory using a two-story test structure with a hydraulic-type active mass damper.

굴삭기의 기구학적 최적설계와 성능해석 (Kinematic Optimal Design of Excavator with Performance Analysis)

  • 한동영;김희국;이병주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.617-622
    • /
    • 1994
  • In this paper, we perform a two-stage, kinematic optimal design for 3 degree-of-freedom excavator system which consists of boom, arm, and bucket. The objective of the first stage is to find the optimal joint parameters which maximize the force-torque transmission ratio between the hydraulic actuator and the rotating joint. The objective of the first stage is to find the optimal link parameters which maximize the isotropic characteristic throughout the workspace. It is illustrated that performances of the optimized excavator are improved compared to those of HE280 excavator, with respect to the described performace index and maximum load handling capacity.

  • PDF

요인배치법에 의한 기어용 소재의 마찰계수 분석 (Analysis of Friction Coefficient for Hydraulic Actuator Materials using Statistical Techniques)

  • 배효준;조연상;우규성;박흥식
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.307-312
    • /
    • 2003
  • The average frictional coefficient was used generally to analyze the moving state of lubricated machine. But It is difficult of getting the correct friction coefficient because the average frictional coefficient of it is progressed always unstably with a large amplitute on driving condition. If correct analysis of frictional coefficient on working condition for lubricated machine can be possible, it can be effect on diagnosis of lubricated machine. The purpose of this study is carried out to get the working condition with a minimum frictional coefficient of transmission gear materials using statistical techniques.

  • PDF

다축 제어용 가진기의 구동소프트웨어 개발 및 보정에 관한 연구 (A Study on Operational Software Development and Calibration of Multi-Axis Vibration Testing Device)

  • 정상화;김재열;류신호
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.143-151
    • /
    • 2001
  • In the recent day, fatigue life prediction techniques play a major role in the design of components in the ground vehicle industry. Full scale durability testing in the laboratory is an essential of any fatigue life evaluation of components or structure of the automotive vehicle. Component testing is particularly important in todey's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, Multi-axis durability testing device is used to carry out the fatigue test. In this paper, The operation software for simultaneously driving Multi-axis vibration testing device is developed and the input and output data are displayed in windows of PC controller with real time. Moteover the characteristics of the displacement and the load of Multi-axis actuators are calibrated separately.

  • PDF

$\textrm{H}_2$제어 기법을 적용한 3층 건물의 능동제어 실험 (Experimental Study on the Active Control of a Three-story Building using $\textrm{H}_2$method)

  • Joo, Soek-Jun;Min, Kyung-Won;Lee, Sung-Kyung;Kim, Sung-Chon;Hong, Sung-Mok
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.225-232
    • /
    • 1999
  • For the study of the seismic-response control, it is necessary to use an experimental system with an earthquake simulator and control devices employing a hydraulic actuator system. However, such system is too expensive to prepare at the university laboratory. In this research, an economical experimental system is developed which has a small-sized earthquake simulator and an AMD using AC servo motors. An accurate mathematical model of the three-degree-of-freedom tests structure with an AMD is developed from the measurement of the input/output relationships of the structure. This paper demonstrates experimentally the efficacy of the frequency domain optimal control algorithm H$_2$in reducing the response of seismically excited building to verify the performance of the experimental system.

  • PDF