• Title/Summary/Keyword: hybrid building

Search Result 452, Processing Time 0.022 seconds

A Study on the Hybrid Floor Adhesive System with Crack Resistance (균열대응성을 보유한 유·무기 복합 하이브리드 바닥 접착시스템 연구)

  • Ko, Hyo-Jin;Kim, Rae-Hwan;Kim, Yong-Ro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.171-172
    • /
    • 2023
  • In order to reduce crack defects caused by the behavior of concrete during floor tile construction, this paper introduced a hybrid floor adhesion system that first constructs an organic adhesive with crack correspondence and attaches tiles with inorganic mortar.

  • PDF

Preliminary Feasibility Study on Wind and Solar Hybrid Power Systems based on Venturi Effects for Buildings (벤투리 효과를 활용한 도심형 건물용 하이브리드 풍력 및 태양광 발전 시스템 기초타당성 예비연구)

  • Suhyun Kim;Yoonsoo Kim;Sumin Park;Jihyeon An;Sanghun Lee
    • New & Renewable Energy
    • /
    • v.19 no.1
    • /
    • pp.22-30
    • /
    • 2023
  • Recently, the use of renewable energy has been increasing to achieve carbon neutrality. The concept of a zero-energy building is also attracting attention. In this study, a preliminary study was conducted to analyze the feasibility of a hybrid wind and solar power generation system between buildings that utilize the building wind generated by the Venturi effect. For this purpose, the wind speed and sunshine hours were monitored in the area where the building wind blows by the Venturi effect, and the power generation depending on system types, areas, and season was estimated. Consequently, the wind power generation system showed a larger amount of power per area than solar power. The wind power systems can generate larger power if wind power blades are installed along the height of the building. As a preliminary study, this study verified the feasibility of the system utilizing building wind and suggested follow-up studies.

A Theoretical Study for Stack Effect driven Natural Ventilation System in High-rise Building (고층건물에서 연돌효과를 활용한 자연환기시스템 설계를 위한 이론적 고찰)

  • Yoon, Sung-Min;Seo, Jung-Min;Kim, Yang-Soo;Lee, Joong-Hoon;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.123-129
    • /
    • 2009
  • In these days, the green building movement caused by the energy crisis is increasing, passive design is getting mere and more attention as it provides many possibilities for energy conservation. Moreover, with the increasing social intention for healthy life, the demand for indoor air Quality is increasing in Korea. As result, the ventilation system which can provide the sound outdoor air constantly has been obliged in Korea. So, the hybrid system which using natural power and mechanical power and makes up for the shortage of mechanical and natural ventilation attracts people's attention in Korea. As a hybrid ventilation system, in this study, the stack effect driven hybrid ventilation system in high-rise residential building will be suggested. And in this paper, the theoretical review for hybrid ventilation system suggested in this study will be addressed. Especially, the characteristics of pressure distribution and airflow caused by stack effect in high-rise residential building and the possibility of natural ventilation as results of stack effect will be described.

  • PDF

Experimental studies into a new type of hybrid outrigger system with metal dampers

  • Wang, A.J.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.2
    • /
    • pp.183-194
    • /
    • 2017
  • This paper presents the experimental investigation into a new type of steel-concrete hybrid outrigger system developed for the high-rise building structure. The steel truss is embedded into the reinforced concrete outrigger wall, and both the steel truss and concrete outrigger wall work compositely to enhance the overall structural performance of the tower structures under extreme loads. Meanwhile, metal dampers of low-yield steel material were also adopted as a 'fuse' device between the hybrid outrigger and the column. The damper is engineered to be 'scarified' and yielded first under moderate to severe earthquakes in order to protect the structural integrity of important structural components of the hybrid outrigger system. As such, not brittle failure is likely to happen due to the severe cracking in the concrete outrigger wall. A comprehensive experimental research program was conducted into the structural performance of this new type of hybrid outrigger system. Studies on both the key component and overall system tests were conducted, which reveal the detailed structural response under various levels of applied static and cyclic loads. It was demonstrated that both the steel bracing and concrete outrigger wall are able to work compositely with the low-yield steel damper and exhibits both good load carrying capacities and energy dispersing performance through the test program. It has the potential to be applied and enhance the overall structural performance of the high-rise structures over 300 m under extreme levels of loads.

The evaluation of concrete high fluidity by the combination of hybrid fiber (하이브리드 섬유의 조합에 따른 콘크리트의 고유동성 평가)

  • Jung, Sang-Kyung;Kim, Young-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.51-52
    • /
    • 2015
  • In this study, the concrete in which the hybrid fiber with different volume and rate was intermixed in high fluidity concrete. However, Fiber Ball is frequently caused by the decrease in the dispersion of the fiber. The research has been conducted primarily study of single fiber or hybrid fiber, such as different length of single fiber. Therefore, we investigate the mechanical properties of concrete was mixed with a combination of various fibers been produced domestically. Its purpose being to provide basic data for evaluating the impact hybrid fibers on the fluidity of concrete.

  • PDF

Power Control modeling and Simulation of Hybrid Power System for Building Microgrid Connected Application

  • Yoon, Gi-Cap;Cho, Jae-Hoon;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.84-93
    • /
    • 2009
  • In this paper, we propose to study the possibility of using a photovoltaic system combined with a high speed micro-turbine. This hybrid system can work as stand-alone system or grid connected system as it will be a part of a micro-grid. Initially, we propose Matlab/Simulink dynamic models of photovoltaic, micro turbine systems and supercapacitor. Then, we carry out a simulation comparison of the two systems, this is, with supercapacitor and without supercapacitor bank. We show that supercapacitor bank as short-term storage device was necessary to reduce the fast fluctuation of power in the case of sensitive loads. It is verified the simulation results of Matlab/Simulink based hybrid power system represent the effectiveness of the suggested hybrid power system.

Effect of Strain Rate on Tensile Behavior of Hybrid Fiber Reinforced Cement-based Composites (하이브리드 섬유보강 시멘트복합체의 인장거동에 미치는 변형속도의 영향)

  • Son, Min-Jae;Kim, Gyu-Yong;Lee, Bo-Kyeong;Lee, Sang-Kyu;Kim, Gyeong-Tae;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.122-123
    • /
    • 2017
  • In this study, the tensile behavior of single and hybrid fiber reinforced cement composite according to strain rate was evaluated. Experimental results, in the strain rate 10-6/s, fiber reinforced cement composite showed improved of tensile strength and decrease of strain at peak stress as SSF volume content increased. In the strain rate 101/s, the single and hybrid reinforced cement composite' s tensile properties are improved, because of the improved bond strength between the fiber and matrix. And hybrid fiber reinforced cement composite showed high energy absorption capacity, because the SSF prevented the cracking and fracture of the surrounding matrix when during the HSF pull-out.

  • PDF

Strain Rate Effect on the Tensile Properties of Steel Fiber Hybrid Reinforced Cement Composites (강섬유를 하이브리드 보강한 섬유보강 시멘트복합체의 인장특성에 미치는 변형속도의 영향)

  • Kim, In-Ho;Kim, Gyu-Yong;Lee, Sang-Kyu;Son, Min-Jae;Kim, Gyeong-Tae;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.87-88
    • /
    • 2018
  • In this study, the tensile properties of single and hybrid fiber reinforced cement composite according to strain rate was evaluated. Experimental results, in the strain rate 10-6/s, fiber reinforced cement composite showed improved of tensile strength and decrease of strain at peak stress as SSF volume content increased. In the strain rate 101/s, the single and hybrid reinforced cement composite's tensile properties are improved, because of the improved bond strength between the fiber and matrix. And hybrid fiber reinforced cement composite showed high energy absorption capacity, because the SSF prevented the cracking and fracture of the surrounding matrix when during the HSF pull-out.

  • PDF

50MPa Ternary Non-Cement Mortar Strength Development Mixing with Hybrid Fibers Cured by Room Temperature (상온양생에 의한 하이브리드 섬유를 혼입한 50MPa급 3성분계 무시멘트 모르타르 강도발현)

  • Cho, Sung-Won;Cho, Sung-Eun;Kim, Young-su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.179-180
    • /
    • 2020
  • CO2 emissions are caused by cement manufacturing process. To solve this problem construction industry are using industrial by-products to replace cement. In this study, three different industrial by products were used and mixed with hybrid fibers to enhance bond strength. As the result, Regardless of the mixing rate of silica fume, the compressive strength of the ternary non cent mortar was higher than that of OPC and binary. And mixed hybrid fibers cured by room temperature compressive strength were 23% higher than those without hybrid fibers.

  • PDF

Estimation of Setting Time and Compressive Strength of the Concrete According to Curing Conditions Using a Hybrid Meter (하이브리드 미터를 이용한 양생조건에 따른 응결 및 압축강도 추정)

  • Park, Jae-Woong;Jeong, Jun-Taek;Lim, Gun-Su;Han, Jun-Hui;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.187-188
    • /
    • 2023
  • This study aimed to evaluate a feasibility of estimating setting time and compressive strength of curing conditions using a Hybrid meter. As a result, It was determined that the measured hardness value at the initial set, final set and at 5MPa of the Hybrid meter were not affected by curing conditions. And the Hybrid meter(A) is confirmed to have a higher correlation, so it is judged to be more suitable for pratical use.

  • PDF