• 제목/요약/키워드: hybrid, fluctuation

검색결과 59건 처리시간 0.024초

풍력발전단지 탈락 시를 고려한 단지 출력 변동 저감을 위한 HESS의 용량 산정 (Determination of the HESS Capacity for Mitigation of Fluctuation of Wind Farm Output under Consideration of Disconnecting Wind Farm)

  • 김승현;고지한;김일환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.388-389
    • /
    • 2013
  • This paper presents the method for the fluctuation smoothing control by using relaxation time variable control of battery. When the output power of wind farm is changed suddenly, it is necessary to control the output power of wind farm. The smoothing relaxation time is changed within limits of battery output power. Using the hybrid energy storage system (HESS) combined with battery energy storage system and electric double layer capacitor, it is possible to control the output power of wind farm. The capacity of battery is determined by considering the case of the disconnecting wind farm from the grid. To verify the proposed method, simulations are carried out by using PSCAD/EMTDC with actual data of wind farm in the Jeju Island.

  • PDF

A Bidirectional Three-level DC-DC Converter with a Wide Voltage Conversion Range for Hybrid Energy Source Electric Vehicles

  • Wang, Ping;Zhao, Chendong;Zhang, Yun;Li, Jing;Gao, Yongping
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.334-345
    • /
    • 2017
  • In order to meet the increasing needs of the hybrid energy source system for electric vehicles, which demand bidirectional power flow capability with a wide-voltage-conversion range, a bidirectional three-level DC-DC converter and some control strategies for hybrid energy source electric vehicles are proposed. The proposed topology is synthesized from Buck and Boost three-level DC-DC topologies with a high voltage-gain and non-extreme duty cycles, and the bidirectional operation principle is analyzed. In addition, the inductor current ripple can be effectively reduced within the permitted duty cycle range by the coordinated control between the current fluctuation reduction and the non-extreme duty cycles. Furthermore, benefitting from duty cycle disturbance control, series-connected capacitor voltages can also be well balanced, even with the discrepant rise and fall time of power switches and the somewhat unequal capacitances of series-connected capacitors. Finally, experiment results of the bidirectional operations are given to verify the validity and feasibility of the proposed converter and control strategies. It is shown to be suitable for hybrid energy source electric vehicles.

퍼지 PI 제어기를 이용한 풍력/디젤 하이브리드 발전시스템의 품질제어 (Power Quality Control of Wind/Diesel Hybrid Power Systems Using Fuzzy PI Controller)

  • 양수형;고정민;부창진;강민제;김정욱;김호찬
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.1-10
    • /
    • 2012
  • This paper proposes a modeling and controller design approach for a wind-diesel hybrid system including dump load. Wind turbine depends on nature such as wind speed. It causes power fluctuations of wind turbine. Excessive power fluctuation at stand-alone power grid is even worse than large-scale power grid. The proposed control scheme for power quality is fuzzy PI controller. This controller has advantages of PI and fuzzy controller. The proposed model is carried out by using Matlab/Simulink simulation program. In the simulation study, the proposed controller is compared with a conventional PI controller. Simulation results show that the proposed controller is more effective against disturbances caused by wind speed and load variation than the PI controller, and thus it contributes to a better quality wind-diesel hybrid power system.

PV와 슈퍼캐패시터 하이브리드에너지시스템 모델 및 제어.운영기술 (Modeling and Operation of Hybrid Energy System with Supercapacitor Bank and PV System)

  • 조재훈;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.291-295
    • /
    • 2009
  • Economic and environmental concerns over fossil fuels encourage the development of photovoltaic(PV) energy systems. Due to the intermittent nature of solar energy. energy storage is needed in a stand-alone PV system for the purpose of ensuring continuous power flow. Grid-connected PV system that supply power in a critical load demand require to curb power fluctuation. In this case. SCB is a effectiveness in controlling power variation due to intrinsic PV system. We propose the Matlab/Simulink dynamic model and power flow characteristics of a hybrid energy system with PV and SCB.

  • PDF

하이브리드에너지시스템용 슈퍼캐패시터 Matlab/Simulink 모델개발 (Modeling and Analysis of Supercapacitor Bank System for Hybrid Energy System)

  • 조재훈;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.285-289
    • /
    • 2009
  • In this paper, we propose to research the dynamic Matlab/Simulink model of supercapacitor bank(SCB) for a microgrid application. We demonstrated that this model id sufficient to design the control system of entire power storage system, SCB, the chopper and grid connected converter. The proposed dynamic model is simulated with the help of Matlab/$Simulink^{TK}$ in the MTG/PC/SCB hybrid energy system. The study results show that SCB have a good performance to curb power fluctuation in building microgrid application.

  • PDF

멀티레벨 컨버터 기반 배전용 능동형 하이브리드 반도체 변압기에 대한 연구 (A Study on Multi-level Converter Based on Distribution Active Hybrid Solid State Transformer)

  • 윤춘기;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.84-86
    • /
    • 2018
  • Active hybrid solid state transformer(AHSST) is newly emerging as a device to maintan the power quality of power distribution. AHSST has a simple structure in which a power electronics device is connected in series to a conventional distribution transformer. The connected power electronics device maintains the constant voltage regardless of the primary grid voltage fluctuation through the secondary voltage control to improve the power quality. It also has a simple structure compare to conventional solid state transformer system and can achieve the same performance with fractionally-rated converter. This paper proposes an multi-level converter based on AHSST system that has a simpler control method and wider voltage control range than the conventional AHSST. The proposed system is verified by simulations.

  • PDF

An Empirical Analysis of Sino-Russia Foreign Trade Turnover Time Series: Based on EMD-LSTM Model

  • GUO, Jian;WU, Kai Kun;YE, Lyu;CHENG, Shi Chao;LIU, Wen Jing;YANG, Jing Ying
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제9권10호
    • /
    • pp.159-168
    • /
    • 2022
  • The time series of foreign trade turnover is complex and variable and contains linear and nonlinear information. This paper proposes preprocessing the dataset by the EMD algorithm and combining the linear prediction advantage of the SARIMA model with the nonlinear prediction advantage of the EMD-LSTM model to construct the SARIMA-EMD-LSTM hybrid model by the weight assignment method. The forecast performance of the single models is compared with that of the hybrid models by using MAPE and RMSE metrics. Furthermore, it is confirmed that the weight assignment approach can benefit from the hybrid models. The results show that the SARIMA model can capture the fluctuation pattern of the time series, but it cannot effectively predict the sudden drop in foreign trade turnover caused by special reasons and has the lowest accuracy in long-term forecasting. The EMD-LSTM model successfully resolves the hysteresis phenomenon and has the highest forecast accuracy of all models, with a MAPE of 7.4304%. Therefore, it can be effectively used to forecast the Sino-Russia foreign trade turnover time series post-epidemic. Hybrid models cannot take advantage of SARIMA linear and LSTM nonlinear forecasting, so weight assignment is not the best method to construct hybrid models.

추측항법과 Loran C항법을 결합한 Hybrid 항법의 정도 (Accuracy of Hybrid Navigation System Combining Dead Reckoning and Loran C)

  • 이원우;신형일
    • 수산해양기술연구
    • /
    • 제20권2호
    • /
    • pp.105-111
    • /
    • 1984
  • 추측항법과 Loran C 항법을 결합한 Hybrid 항법의 정도를 평가하기 위하여, 군산수산전문대학 실습선 전북 401, 403 호에 설치되어 있는 Hybrid항법장치를 이용하여 1982년 7월부터 1983년 6월 사이에 한국서해안 해역에서 실선관측을 행하여 그 측위의 정도를 Radar 위치와 비교.검토한 결과는 다음과 같다. 1. 9970, 5970 Chain의 Loran C 시간차의 표준편차는 각각 약 0.21$\mu$s, 약 0.06$\mu$s로 5970 Chain의 시간차 변동이 9970 Chain보다 적었다. 2. Hybrid위치와 Loran C 위치는 Radar 위치와의 편위거리가 각각 약 0.4 mile, 약 0.51 mile로서 Hybrid 항법이 Loran C 항법보다 정도가 더 높았다. 3. Hybrid 위치와 Loran C의 계산기 simulation 위치는 Radar 위치와의 위치거리가 각각 0.4 mille, dir 0.98 mile로 Hybrid 항법이 Loran C의 계산기 simulation 위치보다 정도가 더 높았으며, 추측위치의 미소한 변동에 대한 Loran C의 변위량을 보정하면 Loran C의 계산기 simulation 위치의 정도도 더 높일 수 있음을 알 수 있었다.

  • PDF

Electric Model of Li-Ion Polymer Battery for Motor Driving Circuit in Hybrid Electric Vehicle

  • Lee, June-Sang;Lee, Jae-Joong;Kim, Mi-Ro;Park, In-Jun;Kim, Jung-Gu;Lee, Ki-Sik;Nah, Wan-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.932-939
    • /
    • 2012
  • This paper presents an equivalent circuit model of a LIPB (Li-Ion Polymer battery) for Hybrid Electric Vehicles (HEVs). The proposed equivalent circuit can be used to predict the charging/discharging characteristics in time domain as well as the impedance characteristic analysis in frequency domain. Based on these features, a one-cell model is established as a function of Depth of Discharge (DoD), and a 48-cell model for a battery pack was also established. It was confirmed by experiment that the proposed model predict the discharging and impedance (AC) characteristics quite accurately at different constant current levels. To check the usefulness of the proposed circuit, the model was used to simulate a motor driving circuit with an Insulated Gate Bipolar Transistor (IGBT) inverter and Brushless DC (BLDC) motor, and it is confirmed that the model can calculate the battery voltage fluctuation in time domain at different DoDs.

상관(Correlation) LMS 적응 기법을 이용한 비선형 반향신호 제거에 관한 연구 (Nonlinear Echo Cancellation using a Correlation LMS Adaptation Scheme)

  • 박홍원;안규영;송진영;남상원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.882-885
    • /
    • 2003
  • In this paper, nonlinear echo cancellation using a correlation LMS (CLMS) algorithm is proposed to cancel the undesired nonlinear echo signals generated in the hybrid system of the telephone network. In the telephone network, the echo signals may result the degradation of the network performance. Furthermore, digital to analog converter (DAC) and analog to digital converter (ADC) may be the source of the nonlinear distortion in the hybrid system. The adaptive filtering technique based on the nonlinear Volterra filter has been the general technique to cancel such a nonlinear echo signals in the telephone network. But in the presence of the double-talk situation, the error signal for tap adaptations will be greatly larger, and the near-end signal can cause any fluctuation of tap coefficients, and they may diverge greatly. To solve a such problem, the correlation LMS (CLMS) algorithm can be applied as the nonlinear adaptive echo cancellation algorithm. The CLMS algorithm utilizes the fact that the far-end signal is not correlated with a near-end signal. Accordingly, the residual error for the tap adaptation is relatively small, when compared to that of the conventional normalized LMS algorithm. To demonstrate the performance of the proposed algorithm, the DAC of hybrid system of the telephone network is considered. The simulation results show that the proposed algorithm can cancel the nonlinear echo signals effectively and show robustness under the double-talk situations.

  • PDF