• Title/Summary/Keyword: humidity changes

Search Result 680, Processing Time 0.027 seconds

Sensitivity Analysis of Indoor Environment Factors along with Changes of Outdoor Air Condition (외기상태의 변화에 따른 실내 환경인자의 민감도 분석)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.2
    • /
    • pp.125-136
    • /
    • 2010
  • The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. A sensitivity analysis of indoor environment factors was carried out to grasp influences along with changes of atmospheric conditions. An integrated multizone model was used to predict these sensitivities. This model was applied to an apartment with six zones. Airflow rates are influenced very seriously by changes of wind direct or wind velocity, but are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air temperatures are influenced very directly by changes of outdoor air temperature, but are influenced very slightly by wind direction or wind velocity and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air humidities are influenced very directly by changes of outdoor air humidity, but are not influenced at all by changes of outdoor air contaminant concentration and have little or no influence by changes of wind direction, wind velocity, or outdoor air temperature. Indoor air contaminant concentrations are influenced very seriously by changes of wind direct or wind velocity, but are influenced somewhat by changes of outdoor air contaminant concentration and are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity.

Changes in the Levels of Ergosterol and Methionine as Indicators of Lentinula edodes Quality According to the Relative Humidity During the Storage Period

  • Park, Youn-Jin;Cho, Yong-Koo;Kim, Chan-Young;Jang, Myoung-Jun
    • Journal of Environmental Science International
    • /
    • v.29 no.12
    • /
    • pp.1199-1204
    • /
    • 2020
  • Lentinula edodes mushrooms cultivated under different relative humidities were wrapped at 4℃ and the results of storage characteristics were investigated. Changes in water content of fruiting bodies during the storage period showed the highest water content in fruit bodies harvested from the treatment with the highest relative humidity. The luminosity of the fresh fruiting bodies showed no significant change during the storage period, and the redness was higher in the relative humidity 95% treatment than in the other treatments. According to this study, the relative humidity of the pileus was 65%, and the content of Ergosterol was 0.67 ± 15 g / L at relative humidity of 65%, 80% and 95%. In addition, amino acid analysis and Principal Component Analysis (PCA) confirmed that methionine was the main cause of changes in storage time and relative humidity.

Influence of air pressure, temperature, humidity and CO$_{2}$ concentration on optical phase changes in thin films

  • Kim, Moon-Hwan;Tachikawa, Yoshihiko;Ogita, Eiji;Ueda, Toshitsugu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.799-804
    • /
    • 1989
  • A new method for measuring optical phase changes of reflection beam from optical mirror is proposed. The optical phase change is liable to change with varying atmosphere conditions. This optical phase changes are measured against air pressure, temperature, humidity and CO$\_$2/ concentration variations. It is clarified that the optical phase changes are most effected by humidity change.

  • PDF

Spatiotemporal Changes of Temperature and Humidity in Lentinula edodes Cultivation Sheds (표고시설재배사내 시·공간적인 온·습도변화)

  • Ryu, Sung Ryul;Koo, Chang Duck
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.6
    • /
    • pp.468-475
    • /
    • 2005
  • To understand spatiotemporal changes of temperature and humidity in Lentimula edodes cultivation sheds, temperature, relative humidity were measured with HOBO H8 series sensors in log cultivation sheds and sawdust cultivation sheds. The results obtained from October in 2003 to October in 2004 were as follows; 1. Horizontal temperature changes were smaller at center of cultivation shed inside than comer of cultivation shed inside, while relative humidity changes were greater about 3% at center of cultivation shed inside than corner of cultivation shed inside. 2. Vertical temperature changes showed that the temperature was higher at above than at below when the temperature rises, while the temperature was lower at above than at below when the temperature falls. Thus close to soil surface temperature showed a little fluctuation. Vertical relative humidity changes showed that the relative humidity was lower at above than at below when the temperature rises, while the relative humidity was higher at above than at below when the temperature falls. After all temperature and relative humidity was the opposite in cultivation shed. 3. It's showed in log cultivation shed that the minimum temperature was a subzero temperature until the end of April, while the minimum temperature did above zero after the beginning of the May. Besides a winter was the greatest at daily temperature range during the four season, about $30^{\circ}C$. On the other hand the minimum relative humidity was less than 20% at April, May and June but more than 40% after May.

Effect of humidity on postmortem changes in rats

  • Seroc Oh;Byeongwoo Ahn;Beom Jun Lee;Sang-Yoon Nam
    • Journal of Veterinary Science
    • /
    • v.25 no.3
    • /
    • pp.24.1-24.9
    • /
    • 2024
  • Importance: In veterinary forensic science, accurately determining the postmortem interval (PMI) is crucial for identifying the causes of animal deaths. Autolysis, a significant postmortem process, influences PMI estimation, but its relationship with humidity is not well understood. Objective: This study aimed to improve the accuracy of PMI estimates in veterinary forensic cases by looking into how different humidity levels affect autolysis in different organs of rats. Methods: The study involved 38 male rats, examining histopathological changes in their heart, liver, and pancreas. These organs were subjected to controlled humidity levels (20%, 55%, and 80%) at a constant 22℃. Tissue samples were collected at several intervals (0 h, 12 h, 24 h, 3 days, and 8 days) for comprehensive analysis. Results: Distinct autolytic characteristics in animal organs emerged under varying humidity conditions. The low-humidity environment rapidly activated autolysis more than the high-humidity environment. In addition, it was found that lower humidity caused nuclear pyknosis, cytoplasmic disintegration, and myofiber interruption. The liver, in particular, showed portal triad aggregation and hepatocyte individuation. The pancreas experienced cell fragmentation and an enlarged intracellular space. High humidity also caused the loss of striations in cardiac tissues, and the liver showed vacuolation. Under these conditions, the pancreas changed eosinophilic secretory granules. Conclusions and Relevance: The study successfully established a clear connection between the autolytic process in PMIs and relative humidity. These findings are significant for developing a more accurate and predictable method for PMI estimation in the field of veterinary forensic science.

Humidity Sensor Using Microstrip Patch Antenna (마이크로스트립 패치 안테나를 이용한 습도 센서)

  • Junho Yeo
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.1
    • /
    • pp.71-76
    • /
    • 2023
  • In this paper, a humidity sensor using a microstrip patch antenna(MPA) and polyvinyl alcohol(PVA) is studied. PVA is a polymer material whose permittivity changes with humidity, and a rectangular slot is added to the radiating edge of the MPA, which is sensitive to changes in electric field, in order to increase the sensitivity to changes in relative permittivity. After thinly coating the area around the radiating edge with the rectangular slot of the MPA fabricated on a 0.76 mm-thick RF-35 substrate with PVA, the changes in the resonant frequency and magnitude of the MPA's input reflection coefficient are measured when relative humidity is adjusted from 40% to 80% in 10% increments at a temperature of 25 degrees using a temperature and humidity chamber. Experiment results show that when the relative humidity increases from 40% to 80%, the resonance frequency of the antenna' input reflection coefficient decreases from 2.447 GHz to 2.418 GHz, whereas the magnitude increases from -7.112 dB to -3.428 dB.

Effects of Relative humidity Conditions on the Compressive Strength Changes of Corrugating Mediums (상대습도조건에 따른 골심지의 압축강도 변화에 관한 연구)

  • 이준호;김수일;하영선
    • Food Science and Preservation
    • /
    • v.7 no.1
    • /
    • pp.63-67
    • /
    • 2000
  • Changes in the compressive strength of four typical corrugating mediums (K$_2$A, AS and S) as affected by relative humidity conditions were compared and their relative cost effectiveness was analysed. All mediums lost their compressive strength as relative humidity increased. at the relative humidity of 93% , As medium lost 58% of its initial strength while S medium did about 40%. Calculations of compress factor and compress factor by price indicated that $K_2$ medium was the most cost effective and maintained the highest compressive strength among the mediums tested. It was recommended that $K_2$ medium could be effectively used to make corrugated fiberboard especially for fresh agricultural product packaging .

  • PDF

Evaluation of DC Resistive Humidity Sensors Based on Conductive Carbon Ink (전도성 카본 잉크를 이용한 직류 저항형 습도센서 제작 및 평가)

  • An, Taechang
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.397-401
    • /
    • 2017
  • A DC resistance type humidity sensor using conductive carbon ink was fabricated and its performance was evaluated. The humidity sensor was fabricated using a screen printing technique and have a structure that does not require additional metal electrodes to measure resistance change. To evaluate the performance of the humidity sensor, we measured the DC resistance change under various relative humidity levels. The fabricated humidity sensor showed a resistance change of about $2.5{\sim}50k{\Omega}$ in 11 ~ 95% RH environment. It also shows a linear relationship in the relative humidity versus log DC resistance graph. In comparison with commercial humidity sensor under real environment, it can be confirmed that the resistance of the humidity sensor changes to almost the same level as the measured humidity. These results show that the resistance type humidity sensor can be operated stably in actual environment.

Effects of Humidity Changes on Eyes (습도 변화가 눈에 미치는 영향)

  • Sun-Hee Han;Bong-Hwan Kim;So-Bin Kim;Min-Jung Kim;Hee-Kyung Park;Hyun-Ji Kim;Heon-Tae Kim;Hyeong-Su Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1616-1624
    • /
    • 2023
  • Purpose. The purpose of this study was to investigate the effect of changes in tear break-up time, accommodative response amount, and accommodative microwave on the eyes due to changes in humidity. Methods. A total of 48 adult men and women in their 20s (21.1±1.56 years old) were surveyed on dry eye questionnaires (OSID questionnaires), tear destruction time was measured by humidity (40%, 60%, 80%), and controlled reactions and controlled fine waves were measured through tactile tests. Result. As a result of the OSID questionnaire, there were 10 normal patients, 8 mild dry eyes, 1 moderate dry eye, and 5 severe dry eyes. The initial tear film destruction time was 7.34±4.67 seconds at 40% humidity, 8.99±4.75 seconds at 60% humidity, 10.26±4.52 seconds at 80% humidity, and the average tear film destruction time was 9.51±4.07 seconds at 40% humidity, 10.99±3.82 seconds at 60% humidity, and 12.05±3.42 seconds at 80% humidity. The accommodative response was -0.41~1.79D at 40% humidity, -0.34~1.79D at 60% humidity, and -0.30~2.01D at 80% humidity. The accommodative microwave was measured as 56.39~63.43dB when it was 40%, 56.41~62.64dB when it was 60%, and 55.96 ~61.13dB when it was 80%. Conclusion. As the humidity (40~80%) increased, the tear break-up time increased, and as the accommodative stimulus amount increased, the accommodative response amount increased. It was found that the accommodative microwave according to the amount of accommodative stimulation increased, and as the humidity increased, the accommodative microwave decreased.

Strength Changes of Corrugated Fiberboard Boxes for Fruits Packaging by Relative Humidity Temperature (과실포장용 골판지 상자의 온습도에 따른 강도 변화)

  • Jo, Jung-Yeon;Min, Choon-Ki;Shin, Jun-Seop;Lee, Myung-Hoon;Sohn, Ki-Zoo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.7 no.2
    • /
    • pp.43-51
    • /
    • 2001
  • This study was carried out to analyze changes of the physical properties of corrugated fiberboard boxes for fruits packaging by various moisture and temperature changes. There were significant decrease in burst strength with increased relative humidity. And also compressive strength(ring crush test) of corrugated fiberboard and box were reduced with moisture content. The decreasing amounts of single wall(SW) corrugated fiberboard was bigger than that of double wall(DW). The physical properties reductions of corrugated fiberboard and box were mainly affected by relative humidity. Therefore, it is suggested that development of the water-resistant corrugated fiberboard and box be useful under the condition of low temperature and high relative humidity such as the cold chain system.

  • PDF