• 제목/요약/키워드: hourly variation

검색결과 139건 처리시간 0.018초

Spatial Gap-Filling of Hourly AOD Data from Himawari-8 Satellite Using DCT (Discrete Cosine Transform) and FMM (Fast Marching Method)

  • Youn, Youjeong;Kim, Seoyeon;Jeong, Yemin;Cho, Subin;Kang, Jonggu;Kim, Geunah;Lee, Yangwon
    • 대한원격탐사학회지
    • /
    • 제37권4호
    • /
    • pp.777-788
    • /
    • 2021
  • Since aerosol has a relatively short duration and significant spatial variation, satellite observations become more important for the spatially and temporally continuous quantification of aerosol. However, optical remote sensing has the disadvantage that it cannot detect AOD (Aerosol Optical Depth) for the regions covered by clouds or the regions with extremely high concentrations. Such missing values can increase the data uncertainty in the analyses of the Earth's environment. This paper presents a spatial gap-filling framework using a univariate statistical method such as DCT-PLS (Discrete Cosine Transform-based Penalized Least Square Regression) and FMM (Fast Matching Method) inpainting. We conducted a feasibility test for the hourly AOD product from AHI (Advanced Himawari Imager) between January 1 and December 31, 2019, and compared the accuracy statistics of the two spatial gap-filling methods. When the null-pixel area is not very large (null-pixel ratio < 0.6), the validation statistics of DCT-PLS and FMM techniques showed high accuracy of CC=0.988 (MAE=0.020) and CC=0.980 (MAE=0.028), respectively. Together with the AI-based gap-filling method using extra explanatory variables, the DCT-PLS and FMM techniques can be tested for the low-resolution images from the AMI (Advanced Meteorological Imager) of GK2A (Geostationary Korea Multi-purpose Satellite 2A), GEMS (Geostationary Environment Monitoring Spectrometer) and GOCI2 (Geostationary Ocean Color Imager) of GK2B (Geostationary Korea Multi-purpose Satellite 2B) and the high-resolution images from the CAS500 (Compact Advanced Satellite) series soon.

부산 해안지역의 고농도 오존 발생 특성에 관한 연구 (Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea)

  • 전병일
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

부산 동삼동 지역의 지표오존농도 특성 연구 (A Study on the Characteristics of Surface Ozone Concentration at Dongsamdong, Pusan)

  • 전병일
    • 환경영향평가
    • /
    • 제8권2호
    • /
    • pp.21-29
    • /
    • 1999
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone and meteorological data of 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was highest in Spring(35.4ppb) and lowest in Winter(22.2ppb). Relative standard deviation indicating clearness of observation site was 0.42 that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong showed maximum at 15~16LST and minimum 07~08LST that typical pattern of ozone concentration. In ozone episode period(May 18~23, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface.

  • PDF

백화점 건물의 에너지 부하모델 개발 (Model Development of Daily and Hourly Energy Load for Department Stores)

  • 박화춘;이승수;김대진
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1088-1094
    • /
    • 2003
  • Case study was peformed to analyze energy load for department stores and develop energy load model to be applied to a cogeneration system. Energy loads of 14 departments were analyzed based on energy load sheets written by operators and energy load of one department store was measured through modem communication for a year. Energy load of department stores shows various variations depending on when they are opened or closed and, hours, days and months. In this paper, the measurement was compared with data in energy load sheets and resolved, and energy load model for a department store was built. It is important to use an accurate energy load model for an accurate feasibility study applying a cogeneration system to buildings.

부산 연안역의 야간 고농도 오존 발생 특성과 기상학적 관련성 (Characteristics of nocturnal maximum ozone and meteorological relevance in Pusan coastal area)

  • 전병일
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.287-292
    • /
    • 1999
  • This study was performed to investigate the characteristics of nocturnal maxiumu ozone occurrence and the meteorological relevance using to hourly ozone data and meteorological data for 1995~1996 in Pusan coastal area. Kwangbokdong showed the highest occurrence of nocturnal maximum ozone as 36.9%, and Deokcheondong showed the lowest occurrence(9.2%) for research period in Pusan. The occurrence rates of nocturnal maximum ozone concentration were decreased toward land area. The low maximum temperature, high minimum temperature, low diurnal range, high relative humidity, high wind speed, high could amount, low sunshine and low radiation were closely related to the main meteorological characteristics occuring the nocturnal maximum concnetration of ozone. It was shown that normal daily variation of ozone concentration by strong photochemical reaction at the before day of nocturnal maximum ozone. The concnetration of nocturnal maximum ozone were occured by entrainment of ozone from the upper layer of developed mixing layer. There are no ozone sources near the ground at night, so that the nighttime ozone should be entrained from the upper layer by forced convection.

  • PDF

OZIPR을 이용한 부산지역 고농도 오존 사례 모사 (A Numerical Simulation of High Ozone Episode Using OZIPR in Busan)

  • 도우곤;이화운;정우식
    • 한국환경과학회지
    • /
    • 제16권8호
    • /
    • pp.985-994
    • /
    • 2007
  • To investigate the effect of NOx and VOCs(volatile organic compounds) on the generation of high ozone episode, examined the hourly variations of ozone, NOx and VOCs concentrations, and calculated the ozone isopleth about maximum ozone concentrations using OZIPR which was presented by U. S. EPA at three sites in Busan. There was some difference by the sites, but decreasing VOCs concentration was effective for reduction of ozone at 22 July, the episode day of 2005. In the year 2006, the episode day was 8 August and the variations of NOx and VOCs concentration was little than variation of ozone. So it was estimated that the photochemical production of ozone was low than transportation of ozone. And the result of the OZIPR modeling was that decreasing VOCs concentration was effective for reduction of ozone.

Model Development of Daily and Hourly Energy Load for Department Stores

  • Park Hwa-Choon;Lee Sung-Soo;Kim Dae-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.169-175
    • /
    • 2004
  • Case study was performed to analyze energy load for department stores and develop energy load model to be applied to a cogeneration system. Energy loads of 14 depart­ments were analyzed based on energy load sheets written by operators and energy load of one department store was measured through modem communication for a year. Energy load of department stores showed various trends depending on when they were opened or closed, or by hour, day and month. In this paper, the measurement was compared with the data in energy load sheets and resolved, and energy load model for a department store was built. It is important to use an accurate energy load model for an accurate feasibility study applying a cogeneration system to buildings.

沿岸境界層에서의 表層風의 日變化 (Diurnal Variation of the Surface Wind in the Coastal Boundary Layer)

  • 최효
    • 한국해양학회지
    • /
    • 제19권2호
    • /
    • pp.210-216
    • /
    • 1984
  • 5년간의 시간별 풍속 자료를 이용하여 연안 표층풍의 일변화가 분석되었다. 특히 내륙으로 부는 바람 (onshore flow)이 지배적인 계절에는 야간 최대풍의 최대 출현 빈도가 자정에 나타났다. 연평균 남풍 계열을 갖는 야간 최대풍은 북풍 계열 보다 약 3배이상의 출현을 보여준다. 중림의 대기 안정도가 연안에 지배적이므로 바람이 해양에서 내륙으로 불 경우는 (offshore flow) 상승된 전선역전층과 지표역전층에 의해 형성된 전단력(shear flow)이 연안경계층으로 전이되어 야간 연안 최대표층풍이 형성된다.

  • PDF

혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I) (Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I))

  • 이민규;서근학
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.509-516
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

  • PDF

혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I) (Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I))

  • 이민규;서근학
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.123-123
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.