• Title/Summary/Keyword: hospital use

Search Result 5,845, Processing Time 0.048 seconds

The Impact of Antibiotic Burden on the Selective Resistance of Gram Negative Bacteria in Children (소아청소년에서의 항생제 사용량 변화에 따른 그람음성 균주의 항생제 내성률 변화 양상)

  • Park, Sera;Lee, Euntaek;So, Hye Jin;Yoo, Ree Nar;Lee, Jina
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.82-91
    • /
    • 2021
  • Background: The purpose of this study was to investigate the association between antibiotic use and the antimicrobial resistance of gram-negative bacteria isolated from blood cultures in a pediatric population. Methods: From January 2014 to June 2018, the antibiotic resistance pattern of Acinetobacter baumannii, Escherichia coli, Klebsiella pneumoniae, and Pseudomonas aeruginosa obtained from bacteremic patients aged ≤18 years hospitalized at Asan Medical Center Children's Hospital was analyzed and the parenteral antibiotic consumption data were retrieved. Results: During the study period, the blood culture was positive for K. pneumoniae (6.4%; 105/1,628), E. coli (5.6%; 91/1,628), P. aeruginosa (3.3%; 54/1,628), and A. baumannii (2.5%; 41/1,628), and the extended-spectrum antibiotic resistance rate of gram-negative bacteria was consistently high. The overall resistance rate of E. coli and K. pneumoniae to extendedspectrum cephalosporin was 49.3% and 54.4%, respectively. Carbapenem-resistant E. coli was first detected in 2014; its overall resistance rate to carbapenem was 5.3%. There was a linear correlation between the usage of 3rd generation cephalosporin and the resistance of A. baumannii (r2=0.96, P=0.004) and carbapenem usage and the resistance of K. pneumoniae (r2=0.79, P=0.045). Conclusions: A positive linear correlation was observed between antibiotic resistance and the corresponding antibiotic usage in 3rd generation cephalosporin resistant A. baumannii and carbapenem resistant K. pneumoniae. The judicious use of antibiotics in healthcare settings is important to minimize selection for extended-spectrum β-lactamase (ESBL) and carbapenem resistance in gram-negative bacteria.

Patterns in the Use and Perception of Digital Breast Tomosynthesis: A Survey of Korean Breast Radiologists (디지털 유방 토모신테시스에 대한 국내 사용 현황과 인식에 관한 설문조사 연구)

  • Eun Young Chae;Joo Hee Cha;Hee Jung Shin;Woo Jung Choi;Jihye Kim;Sun Mi Kim;Hak Hee Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1327-1341
    • /
    • 2022
  • Purpose To evaluate the pattern of use and the perception of digital breast tomosynthesis (DBT) among Korean breast radiologists. Materials and Methods From March 22 to 29, 2021, an online survey comprising 27 questions was sent to members of the Korean Society of Breast Imaging. Questions related to practice characteristics, utilization and perception of DBT, and research interests. Results were analyzed based on factors using logistic regression. Results Overall, 120 of 257 members responded to the survey (response rate, 46.7%), 67 (55.8%) of whom reported using DBT. The overall satisfaction with DBT was 3.31 (1-5 scale). The most-cited DBT advantages were decreased recall rate (55.8%), increased lesion conspicuity (48.3%), and increased cancer detection (45.8%). The most-cited DBT disadvantages were extra cost for patients (46.7%), insufficient calcification characterization (43.3%), insufficient improvement in diagnostic performance (39.2%), and radiation dose (35.8%). Radiologists reported increased storage requirements and interpretation time for barriers to implementing DBT. Conclusion Further improvement of DBT techniques reflecting feedback from the user's perspective will help increase the acceptance of DBT in Korea.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

Analysis of Bone Mineral Density and Related Factors after Pelvic Radiotherapy in Patients with Cervical Cancer (골반부 방사선 치료를 받은 자궁경부암 환자의 골밀도 변화와 관련 인자 분석)

  • Yi, Sun-Shin;Jeung, Tae-Sig
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.15-22
    • /
    • 2009
  • Purpose: This study was designed to evaluate the effects on bone mineral density (BMD) and related factors according to the distance from the radiation field at different sites. This study was conducted on patients with uterine cervical cancer who received pelvic radiotherapy. Materials and Methods: We selected 96 patients with cervical cancer who underwent determination of BMD from November 2002 to December 2006 after pelvic radiotherapy at Kosin University Gospel Hospital. The T-score and Z-score for the first lumbar spine (L1), fourth lumbar spine (L4) and femur neck (F) were analyzed to determine the difference in BMD among the sites by the use of ANOVA and the post-hoc test. The study subjects were evaluated for age, body weight, body mass index (BMI), post-radiotherapy follow-up duration, intracavitary radiotherapy (ICR) and hormonal replacement therapy (HRT). Association between the characteristics of the study subjects and T-score for each site was evaluated by the use of Pearson's correlation and multiple regression analysis. Results: The average T-score for all ages was -1.94 for the L1, -0.42 for the L4 and -0.53 for the F. The average Z-score for all ages was -1.11 for the L1, -0.40 for the L4 and -0.48 for the F. The T-score and Z-score for the L4 and F were significantly different from the scores for the L1 (p<0.05). There was no significant difference between the L4 and F. Results for patients younger than 60 years were the same as for all ages. Age and ICR were negatively correlated and body weight and HRT were positively correlated with the T-score for all sites (p<0.05). BMI was positively correlated with the T-score for the L4 and F (p<0.05). Based on the use of multiple regression analysis, age was negatively associated with the T-score for the L1 and F and was positively correlated for the L4 (p<0.05). Body weight was positively associated with the T-score for all sites (p<0.05). ICR was negatively associated with the T-score for the L1 (p<0.05). HRT was positively associated with the T-score for the L4 and F (p<0.05). Conclusion: The T-score and Z-score for the L4 and F were significantly higher than the scores for the L1, a finding in contrast to some previous studies on normal women. It was thought that radiation could partly influence BMD because of a higher T-score and Z-score for sites around the radiotherapy field. We suggest that a further long-term study is necessary to determine the clinical significance of these findings, which will influence the diagnosis of osteoporosis based on BMD in patients with cervical cancer who have received radiotherapy.

Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function (의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.3-12
    • /
    • 2011
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: From January 1, 2010 December 31, 2010, medical practitioners working in the radiation is classified as a regular personal radiation dosimetry, and subsequently one year 540 people managed investigation department to target workers, dose sectional area, working period, identify the job function-related tasks for a deep dose, respectively, the annual average radiation dose were analyzed. Frequency analysis methods include ANOVA was performed. Results: Medical radiation workers in the department an annual radiation dose of Nuclear and 4.57 mSv a was highest, dose zone-specific distribution of nuclear medicine and in the 5.01~19.05 mSv in the high dose area distribution showed departmental radiation four of the annual radiation dose of Nuclear and 7.14 mSv showed the highest radiation dose. More work an average annual radiation dose according to the job function related to the synthesis of Cyclotron to 17.47 mSv work showed the highest radiation dose, Gamma camera Cinema Room 7.24 mSv, PET/CT Cinema Room service is 7.60 mSv, 2.04 mSv in order of intervention high, were analyzed. Working period, according to domain-specific average annual dose of radiation dose from 10 to 14 in oral and maxillofacial radiology practitioners as high as 1.01~3.00 mSv average dose showed the Department of Radiology, 1-4 years, 5-9 years, respectively, 1.01 workers~8.00 mSv in the range of the most high-dose region showed the distribution, nuclear medicine, and the 1-4 years, 5-9 years 3.01~19.05 mSv, respectively, workers of the highest dose showed the distribution of the area in the range of 10 to 14 years, Workers at 15-19 3.01~15.00 mSv, respectively in the range of the high-dose region were distributed. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

A Study on the Perceived Stress of Mothers in Neonatal Intensive Care Unit (신생아 중환자실에 입원한 환아 어머니의 스트레스)

  • Choi Sung Hee
    • Child Health Nursing Research
    • /
    • v.4 no.1
    • /
    • pp.60-75
    • /
    • 1998
  • The parents have much expectation upon the pregnancy and child birth, and in most cases, they expect the healthy parturient child. However, we can be placed on the high-risk conditions which have the physical, social and immature infant, due to the unexpected results, among the new-born. Accordingly, these high-risk newborn and premature infants will be mostly in NICU, which the concentrated medical treatment can be given, upon their conditions. After their birth and during these periods, they will be divided from the parents, and the nurse will accomplish the bringing-up activities which they can take care of the infant, expected by the parents after their birth. The hospitalization of high-risk newborn including these premature infants is the shocking experience to the parents of family, and thus they can feel the fear and uneasiness, and these reactions of parents are troubled in the behavior at the usual days, and cause the disorder and spiritless status, and these results break the supporting ability of parents, and cause the obstruction. Also, the unavoidable division between the parents and the children as like hospitalization of children can make the parents to feel the alienation emotionally, and this causes the results which the pride on the bringing-up ability of baby gets to be lost. These problems can cause the difficulties on the bonding or the parenting in the further days, and can be related to the neglect and abuse of children. Also, it is gradually increased to study and report which the emotional division by the physical division between the mother and the baby obstructs the normal affection course between the parent and the infant. The stress caused by the birth and the hospitalization of high-risk newborn, as like this, is important in the points which it can uncertainly affect the potential energy for the relationship of parent-child who are finally healthy. Accordingly, the significance and purpose of this study are to understand the contents and degree of stress which the parents of high-risk newborn including the immature child can be experienced from the hospitalization of ICU for their new borns, and thus to offer the basic program to the nursing intervention program for these. The subject of this study is the mother of newborn in NICU of 10 General Hospitals located at the 3one of Pusan, Korea from September 1997 to October 1997, and thus makes the subject of 95 person of parents who agreed to take part in the study and it is descriptive study related to the stress of mother having the newborn in NICU. The method is based on the preceding study related to the stress of mother having the experience of child hospitalization and chronic disease child, and then acquires the advice of specialists group as like 5 nursing professors, and then is amended and supplemented. Total number of questions is 43 items and consists of 5 factors as like medical treatment &nursing procedures, disease status & prognosis, role of parents, communication & inter-personal relationships, hospital environment, and is 5 point Likert Scale. The reliability of this study method is very highly shown to be Cronbach α=0.95. The collected data is analysed as Average, Frequency, Standard Deviation, T-test, ANOVA, Pearson Correlation Coefficient, Duncan multifulrange test by use of SPSS /PC (V7.5). The results of this study is summarized as under. 1. Every characteristics of subject is which the party of mother is 28.70age(±7.48) in the average ages, 51% in the high-school graduate, 38.5% in the christianity, total monthly income is 212.55 thousand won(±1.971), 74.5% in the housewife, 72.9% in the parents and children together living and the number of children to be 1.48person(± 0.6) in average, the recognition on the prognosis of baby is 74.0% in 'Don't know', the relationship with the husband after the hospitalization of babyis 37.3% in 'More Intimate', the relationship with the family of husband to be 48% in 'No-change', and the degree which is consulted with the husband about the baby is 55% in 'very frequently' and the visiting number per week is 4.59(±1.63) in average and the accompanying person in the time of visiting is which the number of husband is 56.3% and thus is the highest. The characteristics of baby is which the age is 21.88days(±16.47) after the birth in average, the sex to be 50 person in the female 52.1% and the order of birth to be 54.2% in the first chid, and the weight in the birth to be 2770gm(±610) and the height in the birth to be 46.26cm(±7.62) in aver age. The medical diagnosis is 37.5% in the premature infant, the career of hospitalization is 96.9% in 'None', and the operation plan is 90.6% in 'None' and the execution of operation is 88% in 'None' and the nursing of incubator is 55.2% in 'Yes', and the method of feeding is 50.5% in 'Oral' and the contents of feeding is 46.9% in the 'Milk'. 2. The total stress degree of subject is almost highly shown to be as 3.36(±0.86). If it is compared upon each cause, 'stress on disease status & prognosis' is highest 3.79(±1.28), and it is in the order of 'stress on medical treatment & nursing procedures' 3.70(±0.93), 'stress on hospital environment' 3.14(±0.86), 'stress on role of parents' 3.18(±0.92) and 'stress on communication & inter personal relationship' 2.62(± 0.77) 3. As the results of checking the notworthiness of stress degree upon each variable of subject, the variable showing the noted difference was the birth weight(γ=-0.16, P=0.04), birth height(γ=-0.23, P=0.03), nursing in the incubator(F=8.93, P=0.04), feed method(F=2.94, P=0.04). That is to say, it is shown which the smaller the birth weight is, the higher the stress degree of mother is noteworthily. Also, the smaller the birth height baby is, the higher the stress of mother is. In the incubator, it os shown which the mother whose baby is nursing in the incubator is higher in the stress degree than other mothers. Upon the feeding method of baby, that is to say, TPNis the highest, and it is shown in the order of NPO, Tube feeding, and P.O. feeding. When we review the above-mentioned results, as the status is serious, it is thought which we include the supporting nursing for coping with the stress of parents in the setting-up od nursing plan for the baby in the NICU.

  • PDF

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.

The Physical and Social Disability of Aged Persons Who Live Alone in Goksung Area (곡성지역(谷城地域) 독거노인(獨居老人)의 신체적(身體的) 사회적(社會的) 능력장애(能力障碍)에 관(關)한 조사(調査))

  • Kim, Shin-Woel;Kim, Young-Lak;Ryu, So-Yeon;Park, Jong;Kim, Ki-Soon;Kim, Yang-Ok
    • Journal of agricultural medicine and community health
    • /
    • v.24 no.2
    • /
    • pp.245-268
    • /
    • 1999
  • It is necessary that the old should have the physical and social ability to perform their daily life. This study is to grasp their degree of disability and problems and suggest their solutions. It surveyed the 87 old people over 65 years old from September 1st until September 30th, in 1997. The findings are as follows. 1) The activities of daily living(ADL) to find their degree of physical disability shows that their average performance ability is 75.9% of all the action while 24.1% of all the old people needs the others' help. As they get older and older, the aged drop off in their physical ability, which is related to a statistical sense (p<0.001). 2) The social disability shows that the aged have their great difference from 9.2% to 85.1% in their instrumental activities of daily living(IADL), intellectual ability and social role. 3) A simple analysis shows that the activities of daily living are, in a statistical sense, related to age(p<0.001), the use of elder's hall(p<0.001), the understanding degree of health(p<0.01) and so forth. 4) A simple analysis shows that the instrumental activities of daily living are, in a statistical sense, related to age(p<0.001), the degree of education(p<0.05), the life of leisure(p<0.001), the understanding degree of health and so forth. 5) A multivariate logistic regression analysis shows that the disability of daily living is related to age, the visit of elder's hall, the period of solitary living, instrumental activities of daily living is age and the visit of elder's hall, and social role is the visit of elder's hall and the decree of education, while intellectual activity has no related variables in a statistical sense.

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Clinical Assessment and Cephalometric Characteristics in Patients with Condylar Resorption (하악과두흡수 환자의 임상적 평가 및 악안면 골격형태에 대한 연구)

  • Koo, Seon-Ju;Kim, Kyun-Yo;Hur, Yun-Kyung;Chae, Jong-Moon;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.91-102
    • /
    • 2009
  • Condylar resorption, or condylysis can be defined as progressive alteration of condylar shape and decrease in mass. Condylar resorption is a poorly understood progressive disease that affects the TMJ and that can result in malocclusion, facial disfigurement, TMJ dysfunction, and pain. The aim of this study was to investigate clinical assessment and cephalometric characteristics in 224 patients with condylar resorption, who visited in the Department of Oral Medicine Kyungpook National University Hospital at 2006, by use of panorama, transcranial view and lateral cephalometric radiograph. The results were as follows; 1. Clinical assessment 1) Total number of patients who visited with chief complaints of TMD were 2419 and 224 (9.3%) among them revealed the condylar resorption, Among patients group with condylar resorption, female was 183 and male was 41, females were predominant. 2) Patient's age ranged from 12 to 70 and mean age was 30.6 years old with a strong predominance for 10s and 20s. Distribution of a showed as follows; 10s was 26.3%, 20s was 34,8%, 30s was 13.8%, 40s was 11.2%, 50s was 7.1%, 60s was 6.3% and 70s was 0.4%. 3) Most of the patients had parafunctional habit. 4) The case of showing the pain in condylar resorption was 145, the case of not showing the pain was 79. 5) Treatment duration of the patients was relatively short. 2. Cephalometric Characteristics 1) ANB which means the retruding of the mandible increased significantly than normal group. The ANB of female was lager than male group as the means of ANB were 5.05 in female and 3.57 in male, 2) SN-GoMe and FMA increased in resorption patients, but FH-PP did not show any significant difference. The FMA of female was lager than male group as the means were 31.69 in female and 30.44 in male. 3) Total posterior facial height was significantly smaller and total anterior facial height showed no significant increase as compared with those of the normal group. Condylar resorption was predominant in young female which was caused by more vertical facial pattern in female than male and increase of parafunctional habit in young age. It was thought that the patients who have a risk factor increasing the compressive stress at condyle caused by obliquely inclined masseter and medial pterygoid show high prevalence of condylar resorption.