• Title/Summary/Keyword: hospital exposure

Search Result 1,481, Processing Time 0.028 seconds

Case-control Study of Risk Factors for Non-Hodgkin Lymphoma in Mumbai, India

  • Balasubramaniam, Ganesh;Saoba, Sushama;Sarade, Monika;Pinjare, Suvarna
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.775-780
    • /
    • 2013
  • Background: In the year 2010, it is estimated that nearly 0.36 million new cases and 0.19 million deaths with Non-Hodgkin lymphoma occurred. In India, among males, NHL incidence rates vary across the country which has encouraged us to conduct a case-control study to study risk factors. Materials and Methods: The present unmatched hospital-based case-control study conducted at Tata Memorial Hospital included subjects registered between the years 1997-99. There were 390 'lymphoma cases' and 1,383 'normal controls. Results: Data on age, tobacco habits, occupational history, dietary factors, tea, coffee were collected by the social investigators. Univariate and multivariate methods were applied for obtaining the odds ratios for risk factors. Conclusions: In the study, cigarette smoking (OR=2.0) and bidi smoking (OR=2.8), were associated with excess risk of lymphoma. Among the dietary items, only consumption of mutton showed 7.3-fold significant excess risk for lymphoma. Consumption of milk showed a 6-fold excess risk (OR=1.5); while coffee showed a 50% reduction in risk for lymphoma. Among occupational exposure, exposure to use of pesticides showed 3-fold excess risk for lymphoma.

Exposure Monitoring of Nonylphenol in Preterm Breast milk in Seoulers (서울 거주 산모의 초유 중 노닐페놀 분석을 통한 인체노출평가)

  • Yi, Bit-Na;Kim, Chang-Sung;Park, Mi-Jung;Han, Yu-Sok;Lee, So-Jung;Yan, Mi-Hi
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.2
    • /
    • pp.113-117
    • /
    • 2008
  • Biomonitoring of nonylphenol (NP), an endocrine disrupting chemical, is required in Korea to perform its proper regulation. Thus, we analyzed exposure levels of nonlyphenol (NP) in breast milk from the mothers who delivered babies within 10 days (N=325). We analyzed free and total forms of NP in breast milk with LC/MS/MS (LOD, 0.5 ppb). In addition, we obtained questionnaires concerning lifestyle from the subject. As results, ranges of total NP were ${\mu}g/L$ (median, $3.51{\pm}4.98{\mu}g/L$ vs. normal, N=281, $2.07{\pm}3.76{\mu}g/L$; p<0.05). In conclusion, we suggest that exposure monitoring of NP should be continuously performed, even though the risks of NP are not clear, yet.

Estimating Benzene Exposure Level over Time and by Industry Type through a Review of Literature on Korea

  • Park, Donguk;Choi, Sangjun;Ha, Kwonchul;Jung, Hyejung;Yoon, Chungsik;Koh, Dong-Hee;Ryu, Seunghun;Kim, Soogeun;Kang, Dongmug;Yoo, Kyemook
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.174-183
    • /
    • 2015
  • The major purpose of this study is to construct a retrospective exposure assessment for benzene through a review of literature on Korea. Airborne benzene measurements reported in 34 articles were reviewed. A total of 15,729 individual measurements were compiled. Weighted arithmetic means [AM(w)] and their variance calculated across studies were summarized according to 5-year period intervals (prior to the 1970s through the 2010s) and industry type. Industries were classified according to Korea Standard Industrial Classification (KSIC) using information provided in the literature. We estimated quantitative retrospective exposure to benzene for each cell in the matrix through a combination of time and KSIC. Analysis of the AM(w) indicated reductions in exposure levels over time, regardless of industry, with mean levels prior to the 1980-1984 period of 50.4 ppm (n = 2,289), which dropped to 2.8 ppm (n = 305) in the 1990-1994 period, and to 0.1 ppm (n = 294) in the 1995-1999 period. There has been no improvement since the 2000s, when the AM(w) of 4.3 ppm (n = 6,211) for the 2005-2009 period and 4.5 ppm (n = 3,358) for the 2010-2013 period were estimated. A comparison by industry found no consistent patterns in the measurement results. Our estimated benzene measurements can be used to determine not only the possibility of retrospective exposure to benzene, but also to estimate the level of quantitative or semiquantitative retrospective exposure to benzene.

Impedance Changes of Living Tissue During Radiation Exposure Dose (방사선 피폭선량에 대한 생체 조직의 임피던스 변화)

  • Kil, Sang Hyeong;Lee, Moo Seok;Nam, Ji Ho;Lee, Yeong Hwa;Kim, Gun Do;Lee, Jong Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.202-207
    • /
    • 2013
  • Bioimpedance involves a lot of information related to living tissue. If there is alteration in bio tissue, its electrical characteristics also change. It is to study electrical characteristics of pork tenderlion in using a HP-4194A Impedance/Gain-phase analyzer instrument and electrical characteristics changes by graded radiation exposure dose. The results were as follow 1. Electrical characteristics of pork tenderlion in repeated measurement had high precision within ${\pm}5$% of coefficiency of variability. 2. During the measurement impedance absolute value and phase alteration did not show statistically significant difference.(p>0.05) 3. While impedance phase of electrical characteristics associated with frequency change was almost stable, impedance absolute value was in inverse proportion to frequency that means high inverse correlation of -0.096(r). 4. Impedance absolute value dropped in radiation exposure dose. The alteration of the value did not show statistically significant difference in 1 Gy, 2 Gy and 4 Gy.(p>0.05) However in radiation exposure dose of 10 Gy, the decrease of impedance absolute value was significantly different.(p<0.05) 5. Impedance phase according to radiation exposure dose change did not show statistically significant difference in 1 Gy, 2 Gy, 4 Gy, and 10 Gy(p>0.05).

Change of PET Image According to CT Exposure Conditions (CT 촬영 조건에 따른 PET 영상의 변화)

  • Park, Jae-Yoon;Kim, Jung-hoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.473-479
    • /
    • 2019
  • PET-CT improves performance and reduces the time by combining PET and CT of spatial resolution, and uses CT scan for attenuation correction. This study analyzed PET image evaluation. The condition of the tube voltage and current of CT will be changed using. Uniformity phantom and resolution phantom were injected with 37 MBq $^{18}F$ (fluorine ; 511 keV, half life - 109.7 min), respectively. PET-CT (Biograph, siemens, US) was used to perform emission scan (30 min) and penetration scan. And then the collected image data were reconstructed in OSEM-3D. The same ROI was set on the image data with a analyzer (Vinci 2.54, Germany) and profile was used to analyze and compare spatial resolution and image quality through FWHM and SI. Analyzing profile with pre-defined ROI in each phantom, PET image was not influenced by the change of tube voltage or exposure dose. However, CT image was influenced by tube voltage, but not by exposure dose. When tube voltage was fixed and exposure dose changed, exposure dose changed too, increasing dose value. When exposure dose was fixed at 150 mA and tube voltage was varied, the result was 10.56, 24.6 and 35.61 mGy in each variables (in resolution phantom). In this study, attenuation image showed no significant difference when exposure dose was changed. However, when exposure dose increased, the amount of dose that patient absorbed increased too, which indicates that CT exposure dose should be decreased to minimum to lower the exposure dose that patient absorbs. Therefore future study needs to discuss the conditions that could minimize exposure dose that gets absorbed by patient during PET-CT scan.

Evaluation of the Chest Radiography using Fuji Computed Radiography(FCR) System (Fuji Computed Radiography(FCR)를 이용한 흥부 X선사진의 평가)

  • Kim, Young-Sung;Kwang, Nam-Sun;Yeo, Young-Bok;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 1991
  • Chest radiograms obtained by using Fuji Computed Radiography(FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic informations than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

  • PDF

URINARY PAH METABOLITES INFLUENCED BY GENETIC POLYMORPHISMS OF GSTM1 IN HOSPITAL INCINERATING WORKERS

  • Lee, Kyoung-Ho;Cho, Soo-Hun;Park, Inmi;Deahee Kang
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.11b
    • /
    • pp.192-192
    • /
    • 2002
  • Hospital waste incinerating workers are exposed to various pyrolysis products including polycyclic aromatic hydrocarbons (PARs). We evaluated their exposure by assessing urinary 1-hydroxypyrene glucuronide (1-OHPG), as internal dose of PAH exposure. The potential effect of genetic polymorphisms of GSTM1/T1 involved in PAH metabolisms was also investigated.(omitted)

  • PDF

Effects of laser-assisted hatching and exposure time to vitrification solution on mouse embryo development

  • Kim, Hye Jin;Park, Sung Baek;Yang, Jung Bo;Choi, Young Bae;Lee, Ki Hwan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.44 no.4
    • /
    • pp.193-200
    • /
    • 2017
  • Objective: This study was conducted to investigate the efficacy of laser-assisted hatching (LAH) and various vitrification times for embryonic development and blastocyst cell numbers. Methods: First, 2-cell and 8-cell embryos were collected by flushing out the oviducts. In the control groups, they were vitrified for 8 or 10 minutes without LAH. The LAH groups underwent quarter laser zona thinning-assisted hatching before vitrification (4, 6, and 8 minutes or 4, 7, and 10 minutes, respectively). After incubation, double-immunofluorescence staining was performed. Results: The hatched blastocyst rate 72 hours after the 2-cell embryos were thawed was significantly higher in the 2LAH-ES8 group (33.3%) than in the other groups (p< 0.05). In the control-8 group ($22.1{\pm}4.6$), the cell number of the inner cell mass was higher than in the LAH groups (p< 0.05). The number of trophectoderm cells was higher in the 2LAH-ES6 group ($92.8{\pm}8.9$) than in the others (p< 0.05). The hatched blastocyst rate 48 hours after the 8-cell embryos were thawed was higher in the 8LAH-ES4 group (45.5%) than in the other groups, but not significantly. The inner cell mass cell number was highest in the 8LAH-ES7 group ($19.5{\pm}5.1$, p< 0.05). The number of trophectoderm cells was higher in the 8LAH-ES10 group ($73.2{\pm}12.1$) than in the other groups, but without statistical significance. Conclusion: When LAH was performed, 2-cell embryos with large blastomeres had a lower hatched blastocyst rate when the exposure to vitrification solution was shorter. Conversely, 8-cell embryos with small blastomere had a higher hatched blastocyst rate when the exposure to vitrification solution was shorter.

Predictors of Blood and Body Fluid Exposure and Mediating Effects of Infection Prevention Behavior in Shift-Working Nurses: Application of Analysis Method for Zero-Inflated Count Data (교대근무 간호사의 혈액과 체액 노출 사고 예측 요인과 감염예방행위의 매개효과: 영과잉 가산 자료 분석방법을 적용하여)

  • Ryu, Jae Geum;Choi-Kwon, Smi
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.5
    • /
    • pp.658-670
    • /
    • 2020
  • Purpose: This study aimed to identify the predictors of blood and body fluid exposure (BBFE) in multifaceted individual (sleep disturbance and fatigue), occupational (occupational stress), and organizational (hospital safety climate) factors, as well as infection prevention behavior. We also aimed to test the mediating effect of infection prevention behavior in relation to multifaceted factors and the frequency of BBFE. Methods: This study was based on a secondary data analysis, using data of 246 nurses from the Shift Work Nurses' Health and Turnover study. Based on the characteristics of zero-inflated and over-dispersed count data of frequencies of BBFE, the data were analyzed to calculate zero-inflated negative binomial regression within a generalized linear model and to test the mediating effect using SPSS 25.0, Stata 14.1, and PROCESS macro. Results: We found that the frequency of BBFE increased in subjects with disturbed sleep (IRR = 1.87, p = .049), and the probability of non-BBFE increased in subjects showing higher infection prevention behavior (IRR = 15.05, p = .006) and a hospital safety climate (IRR = 28.46, p = .018). We also found that infection prevention behavior had mediating effects on the occupational stress-BBFE and hospital safety climate-BBFE relationships. Conclusion: Sleep disturbance is an important risk factor related to frequency of BBFE, whereas preventive factors are infection prevention behavior and hospital safety climate. We suggest individual and systemic efforts to improve sleep, occupational stress, and hospital safety climate to prevent BBFE occurrence.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.