The influence of age, sex, and tooth type on the anatomical relationship between tooth roots and the mandibular canal

  • Pucilo, Michal;Pucilo, Aleksandra;Safranow, Krzysztof;Nowicka, Alicja
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.373-382
    • /
    • 2021
  • Purpose: Cone-beam computed tomography (CBCT) reconstructions were analysed to elucidate factors affecting the anatomical relationship between tooth roots and the mandibular canal(MC). Materials and Methods: Images of 300 volumetric tomography scans of patients aged between 20 and 79 years old (167 women and 133 men) were analysed. The mean distances between 2,053 dental root apices and the internal border of the MC were obtained by measuring the horizontal and vertical distances on coronal CBCT images. The actual distance was then calculated mathematically with the Pythagorean formula. The statistical significance of differences between men and women was assessed using the Mann-Whitney test. Correlations with patient age were evaluated with the Spearman rank correlation coefficient. Results: The mean distances ranged from 2.17 mm, for single right third molar roots in women, to 8.02 mm for single left third molar mesiolingual roots in men. The mean distances measured for the mandibular right second molar mesial roots and the right second premolar roots were larger in men than in women. Age showed a significant positive correlation with the measured distances for mesial and distal roots of the first and second molar on both sides and the right third molar, mesiolingual roots of the left third molar, and single roots of the right third molar. Conclusion: The root-to-mandibular canal distance depended on age and the type of tooth. In 2 root types, this distance was impacted by sex.

Three-dimensional accuracy of different correction methods for cast implant bars

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2014
  • PURPOSE. The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method.

Investigation of passive flow control on the bluff body with moving-belt experiment

  • Rho, Joo-Hyun;Lee, Dongho;Kim, Kyuhong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.139-148
    • /
    • 2016
  • The passive control methods such as horizontal and vertical fences on the lower surface of the bluff body were applied to suppress the vortex shedding and enhance the aerodynamic stability of flow. For investigating the effects of the passive control methods, wind tunnel experiments on the unsteady flow field around a bluff body near a moving ground were performed. The boundary layer and velocity profiles were measured by the Hot Wire Anemometer (HWA) system and the vortex shedding patterns and flow structures in a wake region were visualized via the Particle Image Velocimetry (PIV) system. Also, it is a measuring on moving ground condition that the experimental values of the critical gap distances, Strouhal numbers and aerodynamic force FFT analyses. Through the experiments, we found that the momentum supply due to moving ground caused the vortex shedding at the lower critical gap distance rather than that of fixed ground. The horizontal and vertical fences increase the critical gap distance and it can suppress the vortex shedding. Consequently, the stability characteristics of the bluff body near a moving ground could be effectively enhanced by the simple passive control such as the vertical fences.

Localization of the Mental and Infraorbital Foramen with related to the Soft-tissue Landmarks

  • Lee, Yun-Ho;Lee, Myoung-Hwa;Yu, Sun-Kyoung;Jeong, Goo-Soo;Kim, Do-Kyung;Kim, Heung-Joong
    • International Journal of Oral Biology
    • /
    • v.37 no.1
    • /
    • pp.25-29
    • /
    • 2012
  • During maxillofacial surgery, the infraorbital and mental nerves are blocked at eac foramen to induce local anesthesia. This study examined the relative locations of the infraorbital foramen (IOF) and mental foramen (MF) based on softtissue landmarks. Twenty-eight hemifacial cadavers were dissected to expose the IOF and MF. The distances between the bilateral IOFs, the bilateral MFs, the alae of the nose (alares), and the corners of the mouth (cheilions) were measured directly on cadavers by using a digital vernier caliper. The vertical and horizontal distances of the IOF and MF relative to the alare and cheilion were measured indirectly on digital photographs using Adobe Photoshop (Adobe, CA, USA). The distance between the bilateral IOFs ($58.09{\pm}4.04mm$) was longer than the distance between the bilateral MFs ($50.32{\pm}1.93mm$). The distances between the bilateral alares and cheilions were $41.22{\pm}3.44mm$ and $58.43{\pm}6.62mm$, respectively. The IOF was located $12.92{\pm}3.75mm$ superior and $7.88{\pm}2.56mm$ lateral to the alare, and the vertical angle (Angle 1) between these structures was $31.67{\pm}13.36^{\circ}$ superolaterally. The MF was located $21.83{\pm}3.26mm$ inferior and $5.56{\pm}3.37mm$ medial to the cheilion, and the vertical angle (Angle 2) between these structures was $14.05{\pm}10.12^{\circ}$ inferomedially. In conclusion, these results provide more detailed information about the locations of the IOF and MF relative to soft-tissue landmarks.

The Annual Averaged Atmospheric Dispersion Factor and Deposition Factor According to Methods of Atmospheric Stability Classification

  • Jeong, Hae Sun;Jeong, Hyo Joon;Kim, Eun Han;Han, Moon Hee;Hwang, Won Tae
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.260-267
    • /
    • 2016
  • Background: This study analyzes the differences in the annual averaged atmospheric dispersion factor and ground deposition factor produced using two classification methods of atmospheric stability, which are based on a vertical temperature difference and the standard deviation of horizontal wind direction fluctuation. Materials and Methods: Daedeok and Wolsong nuclear sites were chosen for an assessment, and the meteorological data at 10 m were applied to the evaluation of atmospheric stability. The XOQDOQ software program was used to calculate atmospheric dispersion factors and ground deposition factors. The calculated distances were chosen at 400 m, 800 m, 1,200 m, 1,600 m, 2,400 m, and 3,200 m away from the radioactive material release points. Results and Discussion: All of the atmospheric dispersion factors generated using the atmospheric stability based on the vertical temperature difference were shown to be higher than those from the standard deviation of horizontal wind direction fluctuation. On the other hand, the ground deposition factors were shown to be same regardless of the classification method, as they were based on the graph obtained from empirical data presented in the Nuclear Regulatory Commission's Regulatory Guide 1.111, which is unrelated to the atmospheric stability for the ground level release. Conclusion: These results are based on the meteorological data collected over the course of one year at the specified sites; however, the classification method of atmospheric stability using the vertical temperature difference is expected to be more conservative.

Experiment of the Shelter Effect of Porous Wind Fences base on the Wind Tunnel Test (풍동실험을 이용한 다공성 방풍팬스의 방풍성능실험)

  • You, Jang-Youl;Jeon, Jong-Gil;Kim, Young-Moon
    • Proceeding of KASS Symposium
    • /
    • 2006.05a
    • /
    • pp.91-101
    • /
    • 2006
  • We have conducted the study about the shelter effect against the wind by using the wind fence with various porosities and the measured distance from the wind fence, in three different types of it ; (Circle wind fence, Vertical wind fence, Horizontal wind fence) The shelter effect and turbulence characteristics of the selected wind barrier is throughly investigated by wind tunnel test. flow characteristics of velocities and turbulences behind wind fence were measured using hot-wire anemometer. we characterize the turbulence behind the wind fence by varying the porosity of 0 %, 20 %, 40%, and 60%, and the distances from the wind fence from 1 H to 9 H with maintaining the uniform flow velocity of 6 m/s. In addition, we investigated the overall characterization of the wind fence by measuring total of twenty eight points on the wind fence, which forms the lattice structure on it with seven points in lateral direction and four points in vertical direction. The results of analysis from the circle wind fence indicate that the degree of the turbulence is lowered and the velocity of the wind is decreased when the porosity of 40 % are used at the distance from 3 H to 9 H. On the other hand, the vertical, horizontal wind fence with the porosity of 20% is more advantageous at the distance of 2 H to 9 H. For the effectiveness of the wind fence depending on the position, the center part is the greatest and it decreases at the edges with 10 % to 30 % less than that of at the center.

  • PDF

Study on the analysis of Crosstalk at Interconnects in Integrated Circuits (집적회로의 다층 금속 배선에서의 혼신 특성 해석에 관한 연구)

  • 김연태;최익준;권오섭;원태영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.29-40
    • /
    • 2004
  • This paper reports the frequency characteristics and the time response of parallel adjacent-transmission lines, crossed adjacent-transmission lines and parallel adjacent-transmission lines which are on the different planes by using FDTD-PML method. In the parallel adjacent-transmission lines, the crosstalks as a function of horizontal distance are calculated and in the crossed adjacent- transmission lines, the crosstalks as a function of vertical distance are simulated. Also, the crosstalks as functions of horizontal and vertical distances are measured and analyzed in the parallel adjacent-transmission lines which are on the different planes.

A Morphometric Study of the Obturator Nerve around the Obturator Foramen

  • Jo, Se Yeong;Chang, Jae Chil;Bae, Hack Gun;Oh, Jae-Sang;Heo, Juneyoung;Hwang, Jae Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.282-286
    • /
    • 2016
  • Objective : Obturator neuropathy is a rare condition. Many neurosurgeons are unfamiliar with the obturator nerve anatomy. The purpose of this study was to define obturator nerve landmarks around the obturator foramen. Methods : Fourteen cadavers were studied bilaterally to measure the distances from the nerve root to relevant anatomical landmarks near the obturator nerve, including the anterior superior iliac spine (ASIS), the pubic tubercle, the inguinal ligament, the femoral artery, and the adductor longus. Results : The obturator nerve exits the obturator foramen and travels infero-medially between the adductors longus and brevis. The median distances from the obturator nerve exit zone (ONEZ) to the ASIS and pubic tubercle were 114 mm and 30 mm, respectively. The median horizontal and vertical distances between the pubic tubercle and the ONEZ were 17 mm and 27 mm, respectively. The shortest median distance from the ONEZ to the inguinal ligament was 19 mm. The median inguinal ligament lengths from the ASIS and the median pubic tubercle to the shortest point were 103 mm and 24 mm, respectively. The median obturator nerve lengths between the ONEZ and the adductor longus and femoral artery were 41 mm and 28 mm, respectively. Conclusion : The obturator nerve exits the foramen 17 mm and 27 mm on the horizontal and sagittal planes, respectively, from the pubic tubercle below the pectineus muscle. The shallowest area is approximately one-fifth medially from the inguinal ligament. This study will help improve the accuracy of obturator nerve surgeries to better establish therapeutic plans and decrease complications.

Evaluation of Light Intensity and Uniformity of LEDs for Protected Crop Production

  • Kim, MunJung;Choo, YounKug;Kim, YongJoo;Chung, SunOk
    • Agribusiness and Information Management
    • /
    • v.6 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • This study was conducted to evaluate light intensity and uniformity of two SMD (surface-mount device) type LEDs for protected crop production. A low-power (0.1 W) and a high-power (1 W) LEDs were selected and the intensity and uniformity was evaluated at different vertical (height) and horizontal (distance) intervals. When the horizontal interval of the LED bar was fixed, the light intensity increased and the uniformity decreased as the height decreased. At the 30~40 cm heights, 20~30% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. As the horizontal distance of the LED bars increased, while the uniformity increased as well, the light intensity decreased. At the distances of 6~10 cm, 17~23% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. When the LED bars were added to the sides, the light intensity and uniformity were generally improved. Results showed that the light intensity and uniformity depended on the height and interval of the LED bulbs; therefore, optimum arrangement for the crops interested should be determined through experiments.

Location of maxillary intraosseous vascular anastomosis based on the tooth position and height of the residual alveolar bone: computed tomographic analysis

  • Yang, Seung-Min;Kye, Seung-Beom
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.2
    • /
    • pp.50-56
    • /
    • 2014
  • Purpose: The aims of this study were to measure the distance of the intraosseous vascular anastomosis in the anterolateral wall of the maxillary sinus from different reference points, and to correlate the location of the intraosseous vascular anastomosis with the tooth position and the residual bone height of the maxilla. Methods: Computed tomography (CT) images were taken from 283 patients undergoing dental implants placement in the posterior maxilla. Three horizontal lines were drawn at the ridge crest, maxillary sinus floor, and the position of the anastomosis. A vertical second line at the center of each tooth was drawn perpendicular to the horizontal lines. The distance from the ridge crest to the maxillary sinus floor and the distance from the maxillary sinus floor to the bony canal were measured from the intersections of the horizontal and vertical lines. The residual alveolar bone height was used to categorize three groups: group 1,<4 mm; group 2, between 4 and 8 mm; and group 3, >8 mm. Results: The residual bone height values of different tooth positions were significantly different (P=0.0002). The distance from the maxillary sinus floor to the intraosseous vascular anastomosis was significantly different between groups 1 and 3 (P=0.0039). At the molar sites, a moderate negative correlation was found between the residual bone height and the distance from the maxillary sinus floor to the intraosseous anastomosis. The distances of the alveolar ridge crest and the maxillary sinus from the intraosseous vascular anastomosis were not significantly different between sexes. Conclusions: Within the limitations of this study, sites with a higher residual bone height in the molar regions were at a relatively high risk of artery damage during window osteotomy preparation; therefore, we recommend taking more precautions when using a lateral approach for sinus elevation.