• Title/Summary/Keyword: horizontal

Search Result 11,015, Processing Time 0.035 seconds

A Characteristics of Horizontal Swing Angle of Suspension Clamp in V type Suspension String Sets (V련 현수애자장치의 클램프 횡진 특성)

  • Sohn Hong-Kwan;Lee Hyung-Kwon;Min Byeong-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.3
    • /
    • pp.133-138
    • /
    • 2005
  • This paper presents a characteristics of horizontal swing angle in V type suspension string sets for 765kV T/L. The design of V type suspension string set does not differ from that of general string set for general towers, but it prevents instabilities from swing motion by the horizontal angle and by the wind pressure. We were designed specially 6 conductor yoke, arcing horn and earth horn. And we were decided to 550mm for a distance of strings. We were carried out characteristics of horizontal swing test and movement of mass center test for V-string sets of 400kN single, 300kN double and 400kN double. This products will be used for 765kV T/L of 1 circuit in suspension towers.

Analysis of Scattering Characteristics of the Rectangular Waveguide with a Horizontal Conducting Post using Mode Matching Method and Generalized Scattering Method (모드매칭법과 일반산란계수법을 이용한 수평 금속봉을 갖는 구형 도파관의 산란 특성 해석)

  • 김원기;김상태;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.7
    • /
    • pp.698-705
    • /
    • 2004
  • In this paper, we present the analysis method for a rectangular waveguide with horizontal conducting post using mode matching method and generalized scattering method. Scattering characteristics of a rectangular waveguide with the horizontal conducting post according to radius and height of the post are simulated by the proposed method. The simulated results by proposed method show good agreement with the measured results and the HFSS's results. Proposed method are easily applied to the design of a waveguide component with horizontal conducting posts.

An Experimental Study on the Shear Resistance of Horizontal Shear Reinforcement in R.C. Deep Beams (철근콘크리트 깊은 보에서 수평 전단철근의 전단저항에 관한 실험적 연구)

  • 양근혁;이영호;은희창;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.903-906
    • /
    • 2001
  • The objective of this experimental study was to understand the effect of horizontal shear bar on the shear behavior of R.C. deep beams. Therefore, in the test program, the horizontal shear bar ratio($\rho_{sh}$) and shear span-to-overall depth ratio(a/h) are considered as two main variables. Test results indicate that for deep beams with a/h equal to 1.0, horizontal shear bar is less efficient in restricting the diagonal crack width development and enhancing the ultimate shear strength. So, it can be concluded that shear resistance of horizontal shear bar is related to a/h rather than clear span-to-effective depth ratio($l_{n}$/d) recommended in ACI code.

  • PDF

Dynamic Analysis of Precast Concrete Large Panel Structures with Horizontal Joints (수평 접합부를 고려한 프리캐스트 대형판 구조물의 동적 해석에 관한 연구)

  • 정일영;송진규;강해관
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.249-257
    • /
    • 1996
  • Dynamic Analysis of Precast Concrete Large Panel Structures with Horizontal Joints The damage in precast large panel structures subjected to destructive earthquakes is generally localized in the joints. Particularly, the horizontal joints influence on the stability and integrity of the overall structure. In this research a dynamic analysis was carried out by the macro model that idealized the horizontal joints as inelastic-nonlinear spring systems. It is capable of simulating the behavior of precast concrete structures using the mathematical model. As a result of the dynamic parametric study for the case of 0.12g peak base accelerations, it is found that all joints behave elastically for sliding and opening and that all forces are well distributed without excessive local concentration on my horizontal joints.

  • PDF

Instrumented Field Performance of an Isolated-Reinforced Earth Wall (분리형 보강토옹벽의 현장계측 및 분석)

  • 김영윤;한경제;김경모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.117-124
    • /
    • 2000
  • As the reinforced earth wall is constructed with step by step backfill compaction method, the accumulative horizontal deformation is inevitable. It has been reported that about 80% of horizontal deformation is occurred during the construction stage of reinforced earth retaining wall. To reduce the horizontal deformation, an isolated-reinforced earth wall method(KOESWall system) was newly developed. In this system, the reinforced earth is constructed first with reinforcements and backfills only, and then facing blocks are installed after the horizontal displacement of reinforced earth is fully occurred. To evaluate the effect of a construction method and the performance of KOESWall system, two cases of full scale field performance was monitored during and after the construction stages.

  • PDF

An Experimental Study on the Effect of Consolidation Improvement Using Horizontal Drains (수평배수재를 이용한 압밀개량효과에 대한 실험연구)

  • 김지용;김정기;장연수;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.33-40
    • /
    • 2000
  • The horizontal drain method is one of the soil improvement methods in reclamation works using dredged soils. In this method, plastic drain boards are installed horizontally in the ground, and a seepage pressure or negative pressure is applied through one end of these drains. In this study, a basic consolidation test using horizontal drains was conducted to investigate the effectiveness of this method. The configuration of soil box which was used in this test is 100cm(B)${\times}$100cm(L)${\times}$85cm(H). The drain board was reduced to 25mm${\times}$5mm. The variations in settlement and volume of drain water during the consolidation process were measured, and the distribution of water content and the transpormation of horizontal drain were investigated.

  • PDF

Analyses of Horizontal Behavior of Guardrail Posts Installed in Compacted Weathered Granite Soil (화강풍화토 지반에 타설된 가드레일 지주의 횡방향 거동 분석)

  • Lim, Yu-Jin;Hai, Nguyen Tien
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.41-48
    • /
    • 2005
  • A small scale impact apparatus, pressuremter and soil chamber were used to investigate horizontal behavior and bearing capacity of the steel guardrail post installed in compacted soil. A useful test and data reduction method for pressuremter was developed to evaluate soil parameters of surrounding soil and stability of the post. From the analyses of the PMT, horizontal bearing capacity of the post impacted by a boggie was 12.7% bigger than that of the post with static loading. The increased horizontal bearing capacity is due to generated inertia force that is dependent on the shape of failed soil wedge around the post. P-y curves were obtained from the pressuremeter test and were applied to a finite difference program which predicted a load-deflection and a bending moment contours along the post.

  • PDF

Developement of Consolidation Cell of Horizontal Drainage using Standard Consolidation Tester (표준압밀시험기를 사용하는 수평배수 압밀셀의 개발)

  • Ju, Jae-Woo;Cheong, Gyu-Hyang;Cho, Sam-Deok;Lee, Chun-Ju;Park, Jong-Beom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.678-683
    • /
    • 2004
  • The most popular consolidation tester is a standard consolidatiion tester, which performs consolidation using the step load weight. However this apparatus is used to obtain only the vertical consolidation coefficient. Therefore the purpose of this study is to develope the horizontal consolidation cell for a horizaontal consolidation coefficient. Various size of tests have been peroformed to investigate the effect of scale effect. From the test results, it has turned out that this horizontal consolidation cell has a good function for a horizontal consolidation coefficient.

  • PDF

A study for horizontal control of the Tornado using PWM method (PWM을 이용한 토네이도의 수평제어)

  • 김진호;배형섭;박명관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1713-1716
    • /
    • 2003
  • Casing Oscillator is a construction machine that used to insert casings which is based on construction of a building or bridge into the ground. The purpose of using casing supports a pile or in case when heavy loads and moments happens. It is very important that the casings are retaining perpendicular to sea level regardless of the slope of the ground. So it requires that Casing Oscillator keep horizontality. But, it was useless a horizontal control without another heavy equipment. Tornado is a type of Casing Oscillator to advance. It controls horizontality with 4 cylinders. Those cylinders controlled by high-speed solenoid valves. This paper represents horizontal control of the Tornado using Kinematics. First. the horizontal control simulated by AMESim, which is simulation tool. then it compared with experimental results.

  • PDF

A Study on the Optimization of the Alignment Considering the Ride Comfort in the Case of the Superimposition of Vertical and Horizontal Curves (종곡선/평면곡선 경합 시 승차감을 고려한 선형최적화에 관한 연구)

  • Um, Ju-Hwan;Yang, Sin-Chu;Choi, Il-Yoon
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1943-1950
    • /
    • 2010
  • Superimposition of horizontal and vertical curves may hamper the ride comfort and the running stability of train and largely affect the maintenance cost. However, in many cases, it's not easy to make a track plan because of the fixed points (bridge, tunnel, turnout, catenary system, etc.) to be avoided due to the geographic conditions or to be passed for utilization of existing structures. In this study, when the horizontal and vertical curves are superimposed, in order to optimize the horizontal curve in aspect of the ride comfort, the object function $P_{CT}$ was developed and verified by vehicle dynamic analysis. Also, the solution algorithm for simplified evaluation method was presented.

  • PDF