• Title/Summary/Keyword: hollow module

Search Result 122, Processing Time 0.028 seconds

Mathematical Modelling and Simulation of CO2 Removal from Natural Gas Using Hollow Fibre Membrane Modules

  • Gu, Boram
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.51-61
    • /
    • 2022
  • Gas separation via hollow fibre membrane modules (HFMM) is deemed to be a promising technology for natural gas sweetening, particularly for lowering the level of carbon dioxide (CO2) in natural gas, which can cause various problems during transportation and process operation. Separation performance via HFMM is affected by membrane properties, module specifications and operating conditions. In this study, a mathematical model for HFMM is developed, which can be used to assess the effects of the aforementioned variables on separation performance. Appropriate boundary conditions are imposed to resolve steady-state values of permeate variables and incorporated in the model equations via an iterative numerical procedure. The developed model is proven to be reliable via model validation against experimental data in the literature. Also, the model is capable of capturing axial variations of process variables as well as predicting key performance indicators. It can be extended to simulate a large-scale plant and identify an optimal process design and operating conditions for improved separation efficiency and reduced cost.

Design and Diafiltration Performance of Modified Cellulose and Regenerated Cellulose Hollow Fiber Membrane Hemodiafilter (개질 셀룰로오즈 및 재생 셀룰로오즈 중공사막 혈액투석여과기의 설계 및 투석여과성능)

  • 김재진;박진용
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.221-226
    • /
    • 1993
  • Modules of hemodiafilter were manufactured by using MC-Hp200 and RC-HP4DOA hoi low fiber membranes of Enka Co. in a unique design. The performances of she hemodiafillers were evaluated by measuring the molecular weight cut-off, ultrafiltration rate, clearance, and pressure drop across the hemodiafiter. As a whole, the performances of the RC-HP400A module were superior to those of the MC-Hp200 module. The modules prepared in thls study showed the satisfactory performances for hemodiafiltration.

  • PDF

Development of Ceramic Hollow Fiber Membrane Contactor Modules for Carbon Dioxide Separation (이산화탄소 분리용 세라믹 중공사 접촉막 모듈 기술 개발)

  • Lee, Hong Joo;Che, Jin Woong;Park, Jung Hoon
    • Journal of Climate Change Research
    • /
    • v.7 no.3
    • /
    • pp.249-256
    • /
    • 2016
  • Porous $Al_2O_3$ hollow fiber membranes were successfully prepared by dry-wet spinning/sintering method. The SEM image shows that the $Al_2O_3$ hollow fiber membrane consists mostly of sponge pore structure. The contact angle and the breakthrough pressure were $126^{\circ}$ and 1.91 bar, respectively. This results indicate that the $Al_2O_3$ hollow fiber membranes were successfully modified to hydrophobic surface. The hydrophobic modified $Al_2O_3$ hollow fiber membranes were assembled into a membrane contactor system to separate $CO_2$ from a model gas mixture of the flue gas at elevated gas velocity. The $CO_2$ absorption flux was enhanced when the gas velocity increased from $1{\times}10^{-3}$ to $6{\times}10^{-3}$ m/s. Whereas the $CO_2$ absorption flux was decreased with the number of hollow fiber membrane of a module because of the concentration polarization. Furthermore, we developed an lab-scale $Al_2O_3$ hollow fiber membrane contactor modules and their system (i.e., $CO_2$ absorption using the $Al_2O_3$ membrane and monoethanolamine (MEA)) that could dispose of over $0.02Nm^3/h$ mixture gas (15% $CO_2$) with the removal efficiency higher than 95%. The results can be useful in a field of the membrane contactor for $CO_2$ separation, helping to design and extend a equipment.

A Study on the Characteristics of Mass Transfer in Hollow Fiber Membranes (중공사막에서의 물질전달 특성에 관한 연구)

  • 김기범;김종석;김종수;유일수;이왕로;김성종
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.142-148
    • /
    • 2004
  • This paper presents the enhancement of oxygen transfer efficiency using vibrating intravascular lung assist device (VIVLAD) for patients having chronic respiratory problems. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-actuator, a function generator, and a power amplifier. Gas flow rates of up to 6 L/min through the 120-cm-long hollow fibers have been achieved by exciting a piezo-actuator. The output PVDF sensor and FRF (frequency response function) were investigated by various frequency in VIVLAD. As a result, the maximum oxygen transfer rate was found to occur with maximum amplitude and the transfer of vibration to the hollow fiber membranes. It was excited by the frequency band of 35 Hz at various distilled water flow rates, and various module types.

Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor (PVDF 중공사막 제조 및 벤치규모 기-액 접촉기를 이용한 SO2 흡수특성)

  • Park, Hyun-Hee;Jo, Hang-Dae;Kim, In-Won;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.521-528
    • /
    • 2008
  • The micro-porous asymmetric PVDF hollow fiber membranes for gas-liquid contactor were prepared by the dry-jet wet phase inversion process and the characteristics of hollow fiber membranes were evaluated by the gas permeation method and scanning electron microscope. The chemical absorbent for removal of $SO_2$ gas was sodium hydroxide at bench scale hollow fiber membrane contactor. The experiments were performed in a counter-current mode of operation with gas in the shell side and liquid in the fiber lumen of the module to examine the effect of various operating variables such as concentration of absorbent, gas flow rate, L/G ratio and concentration of inlet $SO_2$ gas on the $SO_2$ removal efficiency using PVDF hollow fiber membrane contactor. Membrane mass transfer coefficient($k_m$) was calculated by mathematical modeling. The volumetric overall mass transfer coefficient increased with increasing the concentration of absorbent and L/G ratio. The increase of the absorbent concentration and L/G ratio not only provides more sufficient alkalinity but also decreases liquid phase resistance. The volumetric overall mass transfer coefficient increased with increasing gas flow rate due to decreasing the gas phase resistance.

Gas Transfer and Hemolysis Characteristics of a New Type Intravenous Lung Assist Device (혈관 내 신형 폐보조장치의 기체전달 및 용혈 특성)

  • 김기범;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The purpose of this work was to assess and quantify whether the beneficial effects in long-term gas exchange at exciting frequency were obtained at different frequencies as well and then to develop a vibrating intravascular lung assist device(VIVLAD), for Patients suffering from acute respiratory distress syndrome(ARDS) or chronic respiratory problems. We investigate the optimal condition of the frequency band excited with new vibrator at state of limit hemolysis when blood hemolysis came to through a membrane vibration action. The experimental design and procedures were given for a device used to assess the effectiveness of membrane vibrations. Quantitative experimental measurements were performed to evaluate the performance of the device . and to identify membrane vibration dependence on blood hemolysis. We developed an analytical solution for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers that is used to provide some insight into how wall vibrations might enhance the performance of the VIVLAD. In the result, it was measured that the effect of various excited frequencies in gas transfer rate and hemolysis from the maximum gas transfer rate at no vibration when the maximum gas transfer rates showed at module type 6, module type 6 consisted of 675 hollow fiber membranes The maximum oxygen transfer rate was caused by the occurrence of maximum amplitude and transfer of vibration to hollow fiber membranes when it was excited by the frequency band of 7Hz at each blood flow rate. because this frequency became the End mode resonance frequency of the flexible in blood flow. Also, when module type 6 was excited at an excited frequency of 7Hz. blood hemolysis was low. Therefore, we decided that the limit of hemolysis frequency is 7Hz . because maximum amplitude occurred at this frequency.

Mathematical modeling of humidification process by means of hollow fiber membrane contactor

  • Marjani, Azam;Baghdadi, Ali;Ghadiri, Mehdi
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.297-311
    • /
    • 2016
  • Modeling and simulation of air humidification by hollow fiber membrane contactors are investigated in the current study. A computational fluid dynamic model was developed by solving the k-epsilon turbulence 2D Navier-Stokes equations as well as mass conservation equations for steady-state conditions in membrane contactors. Finite element method is used for the study of the air humidification under different operating conditions, with a focus on the humidity density, total mass transfer flux and velocity field. There has been good agreement between simulation results and experimental data obtained from literature. It is found that the enhancement of air stream decreases the outlet humidity from 0.392 to 0.340 (module 1) and from 0.467 to 0.337 (module 2). The results also indicated that there has been an increase in air velocity in the narrow space of shell side compared with air velocity wide space of shell side. Also, irregular arrangement has lower dead zones than regular arrangement which leads to higher water flux.

Treatment of Textile Wastewater by Membrane-Bioreactor Process (막-생물반응조 공정을 이용한 염색폐수의 처리)

  • 강민수;김성수;황규대;강종림
    • Membrane Journal
    • /
    • v.7 no.4
    • /
    • pp.175-182
    • /
    • 1997
  • Membrane-bioreactor process which combines anaerobic-aerobic bioreactor and membrane process, was used to remove refractory organic susbstances and dye molecule in textile wastewater effectively. Direct feeding of raw feed water to membrane process caused serious fouling on membrane. On the other hand, pretreated feed by bioreactor before the membrane process remarkably reduced the fouling and prolonged the membrane life. Removal efficiency and fouling were more dependent on the material property of the membrane rather than the membrane pore size and structure. Operation mode of hollow fiber membrane module and linear velocity in the hollow fiber influenced the ramoval efficiency and the water flux of the membrane. The combined membrane- bioreactor process was more effective in treating the textile wastewater than each single process.

  • PDF

Processing Characteristics of the Condensed Wastewater Resulting from Food Waste Disposal using a Submerged Polyethylene Hollow Fiber Membrane (음식물 소멸기에서 발생하는 응축폐수의 Polyethylene 침지형 중공사막을 이용한 처리 특성)

  • Ryu, Jae-Sang;Jeon, Tae-Bong;Kim, Jin-Ho;Chung, Kun-Yong
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • This study is conducted about the system that reduces organism after fermenting food waste from a food waste disposal equipment, divides gas made when food waste is fermented into gas and water, and then sends gas to a reactor again, condenses water, and apply it to the MBR system with submerged MF hollow fiber membranes. A submerged MF hollow fiber membrane module was installed to a food waste disposal equipment and a water treatment system made by Bio Hitech Co,. Ltd. to process food waste generated from a staff cafeteria in a H institute for 90 days. For initial seeding of a food waste disposal equipment, 305 kg of rice bran, chaff, and sawdust as well as 1,648 kg of food were input during the operation, and 1,600 L of condensed wastewater occurred. Fermented by-product after finishing running a food waste disposal equipment was 386 kg and its reduction was shown to be 80%. The organism was processed by applying submerged MF hollow fiber membrane module to the MBR system of condensed wastewater, and the result shows reduction rates were BOD 99.9%, COD 97.5%, SS 98.6%, T-N 54.6% and T-P 34.7% and the total colon bacillus was perfectly eliminated.

Effect of Ozone on Gas Separation Membranes for On-Board Inert Gas Generation System (OBIGGS) (OBIGGS용 기체 분리막에서 오존이 미치는 영향)

  • Jung, Kyung Nam;Woo, Seung Moon;Kim, Se Jong;Kim, Ji Hyeon;Han, Sang Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.28 no.6
    • /
    • pp.406-413
    • /
    • 2018
  • In OBIGGS, a small amount of ozone in the atmosphere damages the polymer membrane. Therefore, the ozone removal device is installed at the front end to prevent the damage of the membrane by reducing the concentration of ozone in the gas delivered to the membrane. In this study, two hollow fiber membranes, PI and PSf, used to fabrication hollow fiber module with an effective membrane area of $6.37cm^2$ for gas separation in OBIGGS. The ozone concentration in the chamber was maintained at 2-3 ppm. The gas was continuously supplied into the module by using a pump. The gas permeation characteristics and the tensile strength were evaluated as a function of ozone exposure time. The PI-based hollow fiber membrane showed only 20% reduction in the transmittance, and remained its original uniformity without any significant changes. However, when PSf type hollow fiber membranes were used, the permeability decreased by more than 80% and the tensile strength decreased by more than 70%.