• 제목/요약/키워드: hole water

검색결과 455건 처리시간 0.028초

마이크로 관류수차의 상수도 관로시스템 적용에 관한 연구 (Application of Micro Cross-Flow Turbine to Water Supply System)

  • 최영도;쿠로카와준이치
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.36-43
    • /
    • 2006
  • Recently, micro hydropower and it's useful utilization are taking a growing interest as a countermeasure of global worming by carbon dioxide and exhaustion of fossil fuel. The purpose of this study is to investigate the possibility of extracting micro hydropower wasted by a valve in water supply system using micro cross-flow hydraulic turbine. In order to fulfill the functions of controlling flow rate and pressure in substitute for the valve, air and water are supplied into an air suction hole which is installed on the side wall of micro cross-flow hydraulic turbine. The results show that in case of supplying a lot of air into the air suction hole, about 50% of flow rate and relatively high value of loss coefficient are controlled by the turbine. Moreover, including high possibility of applying the micro cross-flow turbine to water supply system, extended application of the turbine to the water discharge system of drainage and irrigation canal.

파랑 및 정상흐름에 의한 해저관로 주변의 국부세굴 특성 비교 (Comparison of Local Scour around Pipeline Caused by Waves and Steady Currents)

  • 김경호;오현식
    • 한국해양공학회지
    • /
    • 제25권2호
    • /
    • pp.21-28
    • /
    • 2011
  • The primary purpose of the present study was to investigate the mechanism causing scour around a pipeline placed on the seabed in a shallow water zone. Such submarine pipelines are usually exposed to currents and waves. The present experiments made estimates for each different flow type. The scour width and depth in the equilibrium scour phase were analyzed by non-dimensional parameters. The experiment in this study considered various parameters: pipe diameters, wave periods, wave heights, and current velocities. Using the experimental results, the correlations of scour width, scour depth, and main non-dimensional parameters such as the Fr number and KC number were analyzed. In the case of steady currents, the scour hole was closely related to the bottom velocity, while the scour hole in waves showed a relatively low correlation to the bottom velocity because when exposed to waves the scour hole was restricted according to the movement distance of the water particles during a wave period. However, the scour width under a steady current was not limited because vortex shedding was well developed from having enough time and distance.

Investigation of the tensile behavior of joint filling under experimental test and numerical simulation

  • Fu, Jinwei;Haeri, Hadi;Sarfarazi, Vahab;Marji, Mohammad Fatehi;Guo, Mengdi
    • Structural Engineering and Mechanics
    • /
    • 제81권2호
    • /
    • pp.243-258
    • /
    • 2022
  • In this paper, tensile behavior of joint filling has been investigated under experimental test and numerical simulation (particle flow code). Two concrete slabs containing semi cylinder hole were prepared. These slabs were attached to each other by glue and one cubic specimen with dimension of 19 cm×15 cm×6 cm was prepared. This sample placed in the universal testing machine where the direct tensile stress can be applied to this specimen by implementing a special type of load transferring device which converts the applied compressive load to that of the tensile during the test. In the present work, two different joint filling thickness i.e., 3 mm and 6 mm were prepared and tested in the laboratory to measure their direct tensile strengths. Concurrent with experimental test, numerical simulation was performed to investigate the effect of hole diameter, length of edge notch, filling thickness and filling length on the tensile behavior of joint filling. Model dimension was 19 cm×15 cm. hole diameter was change in four different values of 2.5 cm, 5 cm, 7.5 cm and 10 cm. glue lengths were different based on the hole diameter, i.e., 12.5 cm for hole diameter of 2.5 cm, 10 cm for hole diameter of 5 cm, 7.5 cm for hole diameter of 7.5 cm and 5 cm for hole diameter of 10 cm. length of edge notch were changed in three different value i.e., 10%, 30% and 50% of glue length. Filling thickness were changed in three different value of 3 mm, 6 mm and 9 mm. Tensile strengths of glue and concrete were 2.37 MPa and 6.4 MPa, respectively. The load was applied at a constant rate of 1 kg/s. Results shows that hole diameter, length of edge notch, filling thickness and filling length have important effect on the tensile behavior of joint filling. In fixed glue thinks and fixed joint length, the tensile strength was decreased by increasing the hole diameter. Comparing the results showed that the strength, failure mechanism and fracture patterns obtained numerically and experimentally were similar for both cases.

Multiple-Hole Effect on the Performance of a Sparger During Direct Contact Condensation of Steam

  • Seok Cho;Song, Chul-Hwa;Chung, Heung-June;Chun, Se-Young;Chung, Moon-Ki
    • Journal of Mechanical Science and Technology
    • /
    • 제15권4호
    • /
    • pp.482-491
    • /
    • 2001
  • An experimental study has been carried out to investigate an I-type sparger-performance in view of pressure oscillation and thermal mixing in a pool. Its pitch-to-hole diameter, P/D, varies from 2 to 5. The test conditions are restricted to the condensation oscillation regime. In the present study, two different hole patterns, staggered and parallel types, are employed under various test conditions. The amplitude of the pressure pulse shows a peak for pool temperatures of 45∼85$\^{C}$, which depends on P/D and the steam mass flux. The effect of hole pattern on the pressure load is smaller than that of P/D. The dominant frequency increases with the subcooling temperature of pool water and P/D. A correlation for the dominant frequency is proposed in terms of the pitch-to-hole diameter ratio and other dimensionless thermal hydraulic parameters.

  • PDF

그라우트 재료별 열응답 특성 및 열교환기 운전온도 변화 (Thermal Response Property of Grout Materials from In-situ Test and Temperature Variation of Ground Heat Exchanger)

  • 김갑득;이성주;윤여상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.769-775
    • /
    • 2008
  • The objective of this report is to determine the difference of thermal response that grouted two different materials, and compare the simulation result of the length of total ground heat exchanger length that using the ground thermal conductivity. And also to know heat exchange variation of ground heat exchanger temperature that measured with various test depth. The result shows that the test hole grouted with water permeable material got better thermal response than grouted with water impermeable material. However, with consideration of ingnore for the initial 12 hour data, the test hole grouted with impermeable material has larger thermal conductivity than the other. By former thermal conductivity, simulated data by engineering program shows only 3.4% difference or less. This result shows that ground thermal conductivity is not the main variables for the design program of ground heat exchanger. At the cooling or heating mode, base on the depth of -150m, the ground heat exchanger has best temperature at $-90{\sim}-60m$ and than getting worse because of entering water heat exchanged with leaving water in the same hole.

  • PDF

기존 댐 코어죤의 전단파속도 산정기법 비교 연구 (Study on Comparison of Methods for Estimation of Shear Wave Velocity in Core Zone of Existing Dam)

  • 하익수;오병현
    • 한국지반공학회논문집
    • /
    • 제24권10호
    • /
    • pp.33-43
    • /
    • 2008
  • 본 연구에서는 현재 운영 중인 경상북도 영천시에 위치한 Y댐에 대하여 댐 축조재료 중 코어죤의 최대전단탄성계수 산정을 위한 합리적인 전단파속도를 산정하기 위하여 시추공을 이용한 크로스홀시험과 다운홀시험을 수행하였고, 지표탐사인 MASW(Multi-channel Analysis of Surface Wave, 다중수의 수진기를 이용한 주파수영역 표면파해석)와 반사법 탄성파탐사를 수행하였다. 현장시험으로부터 코어죤의 심도별 전단파속도를 산정하고 그결과들을 비교 분석하였다. 또한, 현장시험 결과와 Sawada의 경험적 제안식을 비교 분석하였다. 본 연구의 목적은 댐 코어죤의 심도별 전단파속도를 산정하기 위해 수행된 4종류의 현장시험 결과를 비교 분석하고, 시험결과와 경험적 제안식을 비교하여 경험식의 적정성을 판단하고, 기존댐 코어죤의 심도별 전단파속도를 합리적으로 산정하는 방법을 제안하는 데 있다. 시험결과, 측정심도 내(18m 이내)에서 다운홀시험, MASW, 반사법탐사에 의한 코어죤의 심도별 전단파속도 산출 결과는 유사한 결과를 보였으며, MASW와 반사법탐사의 경우에는 심도 30m까지 그 산출 결과가 거의 같은 것으로 나타났다. 기존 댐 로어죤의 심도별 전단파속도를 산출하고자 할 때 운영 중인 댐 코어죤에 시추공을 형성하는 것은 현실적으로 매우 어려운 사안임을 감안한다면 MASW나 반사법탄성파탐사와 같은 지표탐사에 의한 전단파속도 산정이 가장 현실적인 방법일 것으로 판단된다. 현장조사가 여의치 않거나 예비조사의 경우에는 기존의 방법과 같이 Sawada의 경험식을 이용할 수 있는데, 경험식을 이용할 경우 Sawada의 제안식 중 하한값을 적용하는 것이 합리적인 방법일 것으로 판단되었다.

고압수 접촉상태가 수압파쇄에 미치는 영향 (The Effects of High Pressure Water Contact State on Hydraulic Fracturing)

  • 이상훈;임종세;장원일
    • 터널과지하공간
    • /
    • 제26권5호
    • /
    • pp.409-417
    • /
    • 2016
  • 본 전통석유자원을 대체할 수 있는 석유자원으로 부상하고 있는 셰일가스가 부존된 셰일층은 낮은 투과성을 가지고 있어 생산성을 향상시키기 위해 수압파쇄법이 적용된다. 본 연구는 일반 시추공과 나선형 홈을 가지는 시추공을 모사한 축소 모형 시험체에 대해 실내수압파쇄 시험을 실행하고 초기파쇄압과 유체접촉상태를 비교 분석하여 공벽형상에 따른 수압파쇄결과를 알아보았다. 또 그 결과를 3차원 개별요소 프로그램인 3DEC을 이용한 수치해석 모델링 값과 비교하였으며, 선행연구 자료와 비교하여 신뢰성 있는 결과를 도출하고자 하였다. 실험결과 고압수의 접촉면적보다는 유도홈의 형태에 의한 응력집중의 효과가 수압파쇄에 더욱 효율적이였다. 따라서 고압수의 응력집중을 높일 수 있는 인공적인 유도홈을 만들 시 적은 수압으로 큰 파쇄효과를 나타낼 수 있을것으로 생각된다.

브라운관용 플런저 냉각표면의 온도분포 개선을 위한 연구 (A Study for Improvement of Temperature Distribution in Plunger Surface Cooling)

  • 곽경민;박지열;배철호
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.126-133
    • /
    • 2008
  • The main objective of the present study is to achieve linear temperature distribution of cooling surface of plunger. K type thermocouples are attached at the surface of plunger to measure temperature. Nozzle and insulating material are inserted in the pin hole of the plunger for this study. Cooling water flow enters at one nozzle and leaves at three nozzles. Flow through nozzle can be activated in the pin hole, temperature of hot point around hole is decreased. Meanwhile, insulating material blocks off heat transfer, temperature of cold point around hole is increased. By combination of nozzle and insulation, heat transfer of hole is controlled effectively, as result its, temperature of plunger surface shows linear temperature distribution.

공기(또는 물) 스프레이형 폐스치로폼 분쇄기 (Scrapped styrofoam crusher with sprayed air (or water))

  • 고관영;김병수;이찬우
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.469-472
    • /
    • 2008
  • This research suggest one-body type scrapped styrofoam crusher with sprayed air (or water), which at present separately composed of dust eliminator, air supplier and crusher. Air (or water) that supplied from compressor injected to rotating twin roller through axis hole, and sprayed out of fine hole on the surface. The crusher that manufactured with sprayed air (or water) can make high-quality primary styrofoam removed pollution and dust. In case of mixed sprayed air and water, clean degree of crushed styrofoam was higher than single sprayed air. This could be contributed to reduce environmental pollution, cost and space in standpoint of recycling scrapped styrofoam.

  • PDF

Slim hole 환형관내 고-액 2상 헬리컬 유동에 관한 연구 (A Study on the solid-liquid helical flow in a slim hole Annulus)

  • 우남섭;황영규;윤치호;김영주
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.465-470
    • /
    • 2006
  • An experimental investigation is carried out to study 2-phase vertically upward hydraulic transport of solid particles by water and non-Newtonian fluids in a slim hole concentric annulus with rotation of the inner cylinder. Rheology of particulate suspensions in viscoelastic fluids is of importance in many applications such as particle removal from surfaces, transport of proppants in fractured reservoir and cleaning of drilling holes, etc. In this study a clear acrylic pipe was used in order to observe the movement of solid particles. Annular fluid velocities varied from 0.2 m/s to 3.0 m/s. Pressure drops and average flow rate and particle rising velocity are measured. For both water and 0.2% CMC solutions, the higher the concentration of the solid particles is, the larger the pressure gradients become.

  • PDF