• Title/Summary/Keyword: holder

Search Result 843, Processing Time 0.027 seconds

A System for Concurrent TMS-fMRI and Evaluation of Imaging Effects (동시 뇌경두개자기자극-기능자기공명영상 시행을 위한 홀더 제작과 시뮬레이션 및 영상 데이터 평가)

  • Kim, Jae-Chang;Kyeong, Sunghyon;Lee, Jong Doo;Park, Hae-Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.169-180
    • /
    • 2013
  • Purpose : The purpose of this study was to setup a concuurent transcranial magnetic stimulation (TMS)-functional MRI (fMRI) system for understanding causality of the functional brain network. Materials and Methods: We manufactured a TMS coil holder using nonmagnetic polyether ether ketone (PEEK). We simulated magnetic field distributions in the MR scanner according to TMS coil positions and angles. To minimize image distortions caused by TMS application, we controlled fMRI acquisition and TMS sequences to trigger TMS during inter-volume intervals. Results: Simulation showed that the magnetic field below the center of the coil was dramatically decreased with distance. Through the MR phantom study, we confirmed that TMS application around inter-volume acquisition time = 100 miliseconds reduced imaging distortion. Finally, the applicability of the concurrent TMS-fMRI was tested in preliminary studies with a healthy subject conducting a motor task within TMS-fMRI and passive motor movement induced by TMS in fMRI. Conclusion: In this study, we confirmed that the developed system allows use of TMS inside an fMRI system, which would contribute to the research of brain activation changes and causality in brain connectivity.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.

Fire Mechanism in Power Connection Points of Outlets and Suggestion of a New Identification Method (콘센트 전원 접속구 화재 발생 메커니즘 고찰과 새로운 감식 방법 제시)

  • Park, Jin-Young;Bang, Sun-Bae;Eun, Hee-Rim;Oh, Se-Hyeok;Lee, Yoo-Bin;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.76-84
    • /
    • 2020
  • Most outlet fires occur around plug pins and plug pin receivers. However, no research has been conducted on ignitions at power connection points. This study confirms the possibility of ignition after incomplete connection, using a stranded wire, to the power connection point of an outlet. The experiment was divided into basic and reproducing experiments. The basic experiment confirmed the possibility of ignition according to the number of wire strands connected to the power connection point, and it identified the characteristics of the residue after the fire. In the reproducing experiment, lamps, vacuum cleaners, and heaters were connected to an outlet to check if the ignition at the connection advanced into a fire. The fire advanced due to the heat and arc generated at the connection point, and partial losses were identified in the U-type holder and clip. Accordingly, the results demonstrate that a fire may occur when the stranded wire is incompletely connected to the outlet. Moreover, it was confirmed that the cause of a fire can be determined based on the characteristics of the residue.

Optimization Method for the Design of LCD Back-Light Unit (LCD Back-Light Unit 설계를 위한 최적화 기법)

  • Seo Heekyung;Ryu Yangseon;Choi Joonsoo;Hahn Kwang-Soo;Kim Seongcheol
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.3
    • /
    • pp.133-147
    • /
    • 2005
  • Various types of ray-tracing methods are used to predict the quantity measures of radiation illumination, the uniformity of illumination, radiation performance of LCD BLU(Hack-Light Unit). The uniformity of radiation illumination is one of the most important design factor of BLU and is usually controlled by the diffusive-ink pattern printed on the bottom of light-guide panel of BLU. Therefore it is desirable to produce an improved (ideally, the optimal) ink pattern to achieve the best uniformity of radiation illumination. In this paper, we applied the Welder-Mead simplex-search method among various direct search method to compute the optimal ink pattern. Direct search methods are widely used to optimize the functions which are often highly nonlinear, unpredictably discontinuous, and nondifferentiable, The ink-pattern controlling the uniformity of radiation illumination is one type of these functions. In this paper, we found that simplex search methods are well suited to computing the optimal diffusive-ink pattern. In extensive numerical testing, we have found the simplex search method to be reasonably efficient and reliable at computing the optimal diffusive-ink pattern. The result also suggests that optimization can improve the functionality of simulation tools which are used to design LCD BLU.

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

A Fundamental Approach for Developing Deformation Strength Based on Rutting Characteristics of Asphalt Concrete (소성변형과의 상관성에 근거한 아스팔트 콘크리트의 변형강도 개발을 위한 기초연구)

  • Kim, Kwang-Woo;Lee, Moon-Sup;Kim, Jun-Eun;Choi, Sun-Ju
    • International Journal of Highway Engineering
    • /
    • v.4 no.4 s.14
    • /
    • pp.23-39
    • /
    • 2002
  • This study dealt with developing a new approach for finding properties which might represent rut resistance characteristics of asphalt mixture under static loading. Two aggregates, a normal asphalt (pen 60-80) and 5 polymer-modified asphalts were used in preparation of 12 dense-graded mixtures. Marshall mix design was used in determination of OAC and each mixture at the OAC was prepared for a newly-developed Kim test on Marshall specimen (S=10cm) and gyratory specimen (S=15cm), and for wheel tracking test. Kim test used Marshall loading frame and specimens were conditioned for 30min at $60^{\circ}C$ before loading through Kim tester an apparatus consisting of a loading column and a specimen and column holder Diameter (D) of column was 3cm and 4cm with each column having different radius (r) of round cut at the bottom. The static load was applied at 50mm/min in axial direction of the specimen, not in diametral direction. The maximum load ($P_{max}$) and vertical deformation (y) at $P_{max}$ point were obtained from the test. A strength value was calculated based on the $P_{max}$ r, D and y by using the equation $K_D = 4P_{max}/{\pi}(D-2(r-\sqrt{2ry-y^2}))^2$ and is defined as the deformation strength ($kgf/cm^2$). The values of $P_{max}$/y and $K_I=K_D/y$ were also calculated. In general the leading column diameter and radius of round cut were significant factors affecting $K_D$ and $P_{max}$ values while specimen diameter was not. The statistical analyses showed the $K_D$ had the best correlation with rut depth and dynamic stability. The next best correlation was found from $P_{max}$ which was followed by $P_{max}$/y and $K_I$ in order.

  • PDF

Fabrication of a Mach-Zehnder interferometer for education using a rotating glass plate and a 3D printer (회전 유리판과 3D 프린터를 이용한 교육용 마흐젠더 간섭계 제작)

  • Jang, Seong-Hun;Ju, Young-G
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.213-220
    • /
    • 2017
  • This paper proposes how to fabricate an educational Mach-Zehnder interferometer that is easy to align and inexpensive, using 3D printers and semiconductor lasers. The interferometer consists of a body $165mm{\times}120mm{\times}57mm$ in size, mirror mounts, a laser holder, beam splitters, and so on. The laser path is adjusted by 4 mirror mounts, each comprised of rubber bands, small metal wires, and a screw. The interference fringe is enlarged by the lens at the final stage. The refractive index of a slide glass was measured by counting the number of moving interference fringes while the slide glass, inserted into one of the two interferometer arms, is rotating. The formula for the refractive index as a function of the optical-path difference and rotation angle was obtained, and used to calculate the refractive index of glass from the interferometer experiment. The use of a rotating glass in one arm of the interferometer nullifies the need for a precision stage, which despite its high cost is often required to observe the moving interference fringe in the classroom. Therefore, the 3D-printed Mach-Zehnder interferometer proposed in this paper can be very useful for education, because of its affordability and performance. It enables students to perform both qualitative and quantitative studies using a 3D-printed interferometer, such as measuring the refractive index of a glass sample, and the wavelength of light.

A Suggestion for Surface Reflectance ARD Building of High-Resolution Satellite Images and Its Application (고해상도 위성 정보의 지표 반사도 Analysis-Ready Data (ARD) 구축과 응용을 위한 제언)

  • Lee, Kiwon;Kim, Kwangseob
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1215-1227
    • /
    • 2021
  • Surface reflectance, as a product of the absolute atmospheric correction process of low-orbit satellite imagery, is the basic data required for accurate vegetation analysis. The Commission on Earth Observation Satellite (CEOS) has conducted research and guidance to produce analysis-ready data (ARD) on surface reflectance products for immediate use by users. However, this trend is still in the early stages of research dealing with ARD for high-resolution multispectral images such as KOMPSAT-3A and CAS-500, as it targets medium- to low-resolution satellite images. This study first summarizes the types of distribution of ARD data according to existing cases. The link between Open Data Cube (ODC), the cloud-based satellite image application platforms, and ARD data was also explained. As a result, we present practical ARD deployment steps for high-resolution satellite images and several types of application models in the conceptual level for high-resolution satellite images deployed in ODC and cloud environments. In addition, data pricing policies, accuracy quality issue, platform applicability, cloud environment issues, and international cooperation regarding the proposed implementation and application model were discussed. International organizations related to Earth observation satellites, such as Group on Earth Observations (GEO) and Committee on Earth Observation Satellites (CEOS), are continuing to develop system technologies and standards for the spread of ARD and ODC, and these achievements are expanding to the private sector. Therefore, a satellite-holder country looking for worldwide markets for satellite images must develop a strategy to respond to this international trend.

Analysis and Improvement of Utilization Status through GPS Data Analysis of Shared Electric Kickboard in Wirye New Town (위례 신도시 공유 전동 킥보드 GPS데이터 분석을 통한 이용실태 분석 및 개선사항)

  • Hong, Seok-Do;You, Yen-Yoo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.9
    • /
    • pp.471-476
    • /
    • 2021
  • Personal mobility (PM) is a new concept of transportation used by one or two people using electricity. Personal transportation aims to move quickly and conveniently over an ambiguous distance that is too close to the destination and too far to walk. In particular, as electric kickboard sharing services have become more common in recent years, they are receiving great popularity from citizens. However, it is necessary to come up with an alternative solution as it is acting as a risk not only to users but also to pedestrians and road drivers. Therefore, in order to present measures to establish and improve a safe personal mobility utilization environment, this research was conducted as follows. First, based on GPS data from shared electric kickboards, the usage status in everyday life was examined and analyzed in detail. Second, it is convenient to rent and return shared electric kickboards directly to applications regardless of time, and it is highly accessible to rent them from their location and reach their destination. Based on these findings, this study suggests that careful access to rental and return could have a more positive effect on users and pedestrians by installing a cradle in a place where there is more use than disorderly device placement and expansion.

Analysis of Patent Trend on Dengue Virus Detection Technology (뎅기 바이러스 검출기술 관련 특허동향 분석)

  • Choi, Jae-Won;Jo, Byung-Gwan;Kim, Hak Yong
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.2
    • /
    • pp.259-268
    • /
    • 2019
  • Dengue virus is a typical mosquito-borne virus, and the half of the world's population is exposed to infection. Dengue virus causes relatively mild symptoms such as dengue fever. However, when not treated properly, it is known to cause severe symptoms such as dengue hemorrhagic fever and dengue shock syndrome with a mortality rate of over 20%. Development of dengue virus detection technology is very important because it is reported that early diagnosis of dengue fever can lower the mortality rate to less than 1%. In this study, patent search related to dengue virus detection technology was conducted in Korea, USA, Europe, Japan, and China. The quantitative analysis of 69 validated patents from the searched patents was conducted by country, year, and patent holder. In addition, in-depth analysis was carried out by classifying into three categories: molecular diagnostics, immuno-diagnostics, and cell culture-based diagnostics from all validated patents. From these results, we analyzed the patent trend related to dengue virus detection and dengue fever diagnosis technology and discussed the features and limitations of molecular diagnostics and immuno-diagnostics at present level. Furthermore, we discussed the direction of technology development and future prospects to overcome limitations.