• 제목/요약/키워드: high-strength strand

검색결과 40건 처리시간 0.022초

고강도 프리텐션 프리스트레스트 콘크리트 부재 단부 영역에서의 PS 강연선 부착특성 연구 (Bond Characteristics of PS Strand around the End Zones of High Strength Pretensioned Prestressed Concrete Members)

  • 김동백;김의성
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.102-107
    • /
    • 2000
  • The extensive use of pretensioned prestressed concrete in the modem construction industry, together with wider application of pretensioned components for structural purposes requires some important consideration on the adequate transfer of prestress force into the concrete, especially around the end zones of pretensioned member. The main objective of this paper is to study the effects of various important parameters on the bond characteristics of prestressing strand around the end zone of high strength pretensioned concrete members. To this end, a comprehensive experimental program has been set up. The principal test variables considered were strand diameter, concrete strength, concrete cover size. The present study provides valuable test data for the realistic and accurate determination of transfer length, which can be efficiently used for improving the design equation of transfer length in pretensioned prestressed concrete members.

  • PDF

포스트텐션 PSC 거더에 대한 2400 MPa급 강연선의 적용성 분석 (Investigation on Applicability of 2400 MPa Strand for Posttensioned Prestressed Concrete Girders)

  • 박호;조재열;김지상
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.727-735
    • /
    • 2012
  • 최근 국내 기술로 기존의 PS 강연선보다 인장강도가 크게 증가한 2400 MPa급 고강도 강연선이 세계 최초로 개발되었다. KS D 7002는 2011년 고강도 강연선을 반영하는 개정을 통하여 고강도 강연선의 실용화를 뒷받침하였다. 그러나 고강도 강연선의 역학적 특성과 구조물 적용시 실제 성능에 대한 논의와 검증이 아직 미비한 실정이고 고강도 강연선의 적용을 위한 설계기준의 개정 여부 역시 자세한 검토가 이루어지지 않았다. 고강도 강연선의 실용화를 위해서는 이러한 성능 검증과 설계기준 검토가 우선 수행될 필요가 있다. 이 연구에서는 휨성능 검증 실험에 앞서 단면해석을 통해 휨거동을 예측하였으며 해석 결과를 바탕으로 국내외 설계기준을 비교 검토하였다. 또한 고강도 강연선의 적용에 따른 현 설계기준의 개정 필요성을 논의하였다. 휨거동 측면에서 집중적으로 논의된 부분은 강연선의 응력 추정이었으며 이와 관련하여 강연선의 항복점 정의방법, 고강도 강연선의 장기 손실, 부재 파괴시 강연선 응력 추정식, 부재 연성파괴를 보장하기 위한 인장지배변형률 한계를 논의하였다. 논의 결과 일부 개정 필요성이 제기되었으며 이에 대한 추가의 연구가 필요할 것으로 판단된다.

고강도 강연선용 앵커헤드의 형상변화에 따른 비선형 거동특성 분석 (Nonlinear Analysis of Anchor Head for High Strength Steel Strand)

  • 노명현;성택룡;김진국
    • 한국전산구조공학회논문집
    • /
    • 제25권2호
    • /
    • pp.163-173
    • /
    • 2012
  • 이 연구에서는 프리스트레싱용 고강도 강연선의 정착장치 중 강연선을 직접 정착하는 앵커헤드(anchor head)에 대해 거동특성을 분석하고, 앵커헤드의 제원을 결정하는 단계에 있어서 해석적 검토에 요구되는 프로세스에 대해 정립하였다. 앵커헤드는 쐐기와의 접촉(contact)을 통해 강연선으로부터의 힘이 전달되고 거동변화에 따라 접촉상태 또한 변하게 된다. 이를 고려한 상세 거동분석을 위해 쐐기와 헤드 사이의 접촉(contact)조건을 설정하였으며, 앵커헤드의 비선형 재료모델을 적용하여 기하 및 재료 비선형성을 고려한 구조해석을 수행하였다. 해석결과로부터 다음의 결과를 얻을 수 있었다. 앵커헤드의 거동은 앵커헤드와 쐐기 간의 상호거동에 크게 영향을 받기 때문에 초기 설계단계부터 상대 영향을 고려해야 한다. 쐐기홀(wedge hole)의 배치는 층배열(layered) 보다는 원형배열(circular)이 보다 응력분배에 효과적이고, 쐐기홀의 간격을 증가시키고 헤드 하면 구멍의 크기를 줄여 구멍사이 강재의 두께를 다소 늘이는 것이 구조거동에 효과적이다.

스트랜드 인장시편을 적용한 탄소섬유/에폭시 복합재의 열화특성 연구 (Characteristics of Thermal Degradation for Carbon Fiber/Epoxy Composite using Strand Specimen)

  • 오진오;길형배;윤성호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.408-410
    • /
    • 2012
  • 본 연구에서는 수지 인장시편과 스트랜드 인장시편을 적용하여 탄소섬유/에폭시 복합재의 고온에서의 특성을 조사하였다. 연구결과에 따르면 수지시편의 인장강성은 수지의 유리전이 온도에 근접해감에 따라 서서히 감소하지만 스트랜드 인장시편의 인장강성은 상온에서의 인장강성을 유지한다. 수지시편과 스트랜드 시편의 인장강도는 온도가 유리전이 온도에 근접할수록 급격한 감소를 나타내었다.

  • PDF

고온 환경하에서의 CFRP의 인장강도특성에 관한 연구 (Study on the Tensile Strength Characteristics of CFRP under the High Temperature Condition)

  • 박재범;황태경;김형근;도영대
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.86-89
    • /
    • 2006
  • 고온 특성이 매우 우수한 탄소섬유와 상대적으로 내열성능이 취약한 Epoxy수지로 구성된 CFRP재의 고온 환경 하에서의 인장강도 특성에 관한 실험적 및 해석적 연구가 수행되었다. 특히, CFRP재의 인장 강도특성에 결정적으로 작용하는 섬유와 Epoxy 수지와의 계면의 특성에 초점을 맞추었으며, 고온 환경하에서 점차적으로 저하되는 계면 강도의 변화가 CFRP재의 인장강도에 미치는 영향을 정량적으로 평가하였다. 이를 위해, Strand 인장 및 Short Beam 시험을 고온 환경 하에서 실시하였으며, Curtin-Takeda Model를 도입하여 이론해석을 실시하였다.

  • PDF

Tensile behavior of new 2,200 MPa and 2,400 MPa strands according to various types of mono anchorage

  • Kim, Jin Kook;Seong, Taek Ryong;Jang, Kyung Pil;Kwon, Seung Hee
    • Structural Engineering and Mechanics
    • /
    • 제47권3호
    • /
    • pp.383-399
    • /
    • 2013
  • High-strength strands are widely used as a key structural element in cable-stayed bridges and prestressed concrete structures. Conventional strands for stay cable and tendons in prestressed concrete structures are ${\phi}$15.7mm coated seven-wire strands and ${\phi}15.2mm$ uncoated seven-wire strands, respectively, but the ultimate strengths of both strands are 1860MPa. The objective of this paper is to investigate the tensile behavior of a newly developed ${\phi}15.7mm$ 2,200 MPa coated strand and a ${\phi}15.2mm$ 2,400 MPa uncoated strand according to various types of mono anchorages and to propose appropriate anchorages for both strands. Finite element analyses were initially performed to find how the geometry of the anchor head affects the interaction among the anchor head, the wedge and the strand and to find how it affects the stress distributions in both parts. Tensile tests for the new strands were carried out with seven different types of mono anchorages. The test results were compared to each other and to the results obtained from the tensile tests with a grip condition. From the analysis and the test results, desirable mono anchorages for the new strands are suggested.

초전도 마그네트용 실용 초전도 복합선재의 기계적 특성 및 피로손상 평가에 관한 연구 (Evaluation of Mechanical Property and Fatigue Damage in A Practical Superconducting Cable for Magnet)

  • 신형섭;오상수
    • 대한기계학회논문집A
    • /
    • 제24권3호
    • /
    • pp.761-768
    • /
    • 2000
  • In order to investigate how the fatigue damage effects on the critical properties of superconductor, a fatigue test at room temperature and an Ic measurement test at 4.2K were carried out in this study, respectively, using a 9 strand Cu-Ni/NbTi/Cu composite cable. Through the fatigue test of a 9 strand Cu-NUNbTi/Cu composite cable, a conventional S-N curve was plotted even though there was a possibility of fretting among strands. It was found that the maximum stress corresponding to the inflection point on the S-N curve obtained was nearly the same value as the yielding strength of cable obtained from the static tensile test. However, the effect of cabling in multi-strands superconducting cable on the fatigue strength was not noticeable. The critical current(Ic) measurement was carried out at 4.2K in a NbTi strand out of the fatigued cable. It showed a degradation of lc at high stress amplitude regions over 380NTa, and the degradation became significant as the applied stress amplitude increased.

완전 함침된 프리프레그 테이프의 성형방법 및 응용분야 (Manufacturing of fully impregnated prepreg tape and its applications)

  • 이건웅;박민;김준경;최철림;이재식;정호갑
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.245-248
    • /
    • 2002
  • Research on the high performance and strength thermoplastic/continuous fiber composites was performed. New concept of impregnating die for developing continuous strand and prepreg tape of engineering plastic/glass fiber was introduced and estimated. Fully impregnated prepreg strand and tape was successfully manufactured through the new pin structure of impregnating die and control of spreading variable. Also design variables for stability of increasing processing speed were shown. And tensile strength of prepreg tape manufactured in this study was much higher than composites made by other competition company.

  • PDF

Transfer length of 2400 MPa seven-wire 15.2 mm steel strands in high-strength pretensioned prestressed concrete beam

  • Yang, Jun-Mo;Yim, Hong-Jae;Kim, Jin-Kook
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.577-591
    • /
    • 2016
  • In this study, the transfer length of 2400 MPa, seven-wire high-strength steel strands with a 15.2 mm diameter in pretensioned prestressed concrete (PSC) beams utilizing high strength concrete over 58 MPa at prestress release was evaluated experimentally. 32 specimens, which have the variables of concrete compressive strength, concrete cover depth, and the number of PS strands, were fabricated and corresponding transfer lengths were measured. The strands were released gradually by slowly reducing the pressure in the hydraulic stressing rams. The measured results of transfer length showed that the transfer length decreased as the concrete compressive strength and concrete cover depth increased. The number of strands had a very small effect, and the effect varied with both the concrete cover depth and concrete strength. The results were compared to current design codes and transfer lengths predicted by other researchers. The comparison results showed that the current transfer length prediction models in design codes may be conservatively used for 2400 MPa high-strength strands in high-strength concrete beams exceeding 58 MPa at prestress release.

고연성 PET-AF 스트랜드로 외부 보강한 RC 원형 기둥의 내진 성능에 관한 실험적 연구 (Experimental Investigation on Seismic Performance of RC Circular Columns Strengthened Using Highly-Ductile PET-AF Fiber Strand)

  • 곰보수렌 진저릭트;김소영;최동욱;임명관;이진용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권5호
    • /
    • pp.56-66
    • /
    • 2017
  • 이 연구에서는 고연성 PET 시트 및 HF(PET+aramid) 스트랜드로 보강한 RC 원형 기둥의 내진 보강 성능에 대하여 실험적으로 비교 고찰하였다. 고연성 PET 및 HF 스트랜드로 횡 구속된 RC 원형 기둥의 내진 성능 실험결과, 모든 보강 기둥에서 최대 휨 강도 및 연성 능력 모두 무보강 기둥보다 향상되었으며 극한단계에서 섬유의 파단은 발생하지 않았다. 또한 PET 시트 25겹 보강 기둥과 HF 스트랜드 1겹 보강 기둥의 저항 내력 및 변위가 거의 유사하여 HF 스트랜드 1겹은 PET 시트 약 25겹(동일 폭 기준)과 동일한 횡 구속 효과를 나타내었다. 결과적으로 휨 강도 증진 및 연성 능력 측면에서 PET는 RC 구조물의 내진 보강재로서 적합한 것으로 사료되나 현장적용의 가능성을 높이기 위해서는 이 연구에서 사용된 HF 스트랜드와 같이 많은 양의 섬유를 함유한 제작품과 같이 1겹으로 다수 PET 시트의 성능 효과를 내는 재료가 필요할 것으로 사료된다. 한편 PET의 내구성에 대해서는 별도의 연구가 필요하며 현재 연구가 진행중이다.