Browse > Article
http://dx.doi.org/10.12989/sem.2013.47.3.383

Tensile behavior of new 2,200 MPa and 2,400 MPa strands according to various types of mono anchorage  

Kim, Jin Kook (Energy Infrastructure Research Department, Steel Structure Research Division, Research Institute of Industrial Science and Technology, POSCO Global R&D Center)
Seong, Taek Ryong (Energy Infrastructure Research Department, Steel Structure Research Division, Research Institute of Industrial Science and Technology, POSCO Global R&D Center)
Jang, Kyung Pil (Department of Civil and Environmental Engineering, Myongji University)
Kwon, Seung Hee (Department of Civil and Environmental Engineering, Myongji University)
Publication Information
Structural Engineering and Mechanics / v.47, no.3, 2013 , pp. 383-399 More about this Journal
Abstract
High-strength strands are widely used as a key structural element in cable-stayed bridges and prestressed concrete structures. Conventional strands for stay cable and tendons in prestressed concrete structures are ${\phi}$15.7mm coated seven-wire strands and ${\phi}15.2mm$ uncoated seven-wire strands, respectively, but the ultimate strengths of both strands are 1860MPa. The objective of this paper is to investigate the tensile behavior of a newly developed ${\phi}15.7mm$ 2,200 MPa coated strand and a ${\phi}15.2mm$ 2,400 MPa uncoated strand according to various types of mono anchorages and to propose appropriate anchorages for both strands. Finite element analyses were initially performed to find how the geometry of the anchor head affects the interaction among the anchor head, the wedge and the strand and to find how it affects the stress distributions in both parts. Tensile tests for the new strands were carried out with seven different types of mono anchorages. The test results were compared to each other and to the results obtained from the tensile tests with a grip condition. From the analysis and the test results, desirable mono anchorages for the new strands are suggested.
Keywords
high-strength strand; 2,200 MPa; 2,400 MPa; tensile test; mono anchorage; pre-stressed concrete; cable-stayed bridge;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Al-Mayah, A., Soudki, K. and Plumtree, A. (2013), "Towards a simplified anchor system for CFRP rods", Journal of Composites for Construction. (in press)
2 ASTM International (2012), "Standard Specification for Steel Strand, Uncoated Seven-Wire for Prestressed Concrete", ASTM A416, USA
3 EOTA (2002), "Guideline for European Technical Approval of Post-Tensioning Kits for Prestressing of Structures (ETAG 013)", EOTA, Brussels.
4 Fib (2005), "Acceptance of stay cable systems using prestressing steels", International Federation for Structural Concrete fib, Lausanne, Switzerland.
5 Godfrey, H.J. (1956), "The physical properties and methods of testing prestressed concrete wire strand", PCI Journal, 1(3), 38-47.
6 Hill, A.T. Jr. (2006), "Material properties of grade 300 and grade 270 prestressing strands and their impact on the design of bridges", M.S. Thesis, Virginia Polytechnic Institute and State University, Blacksburg,VA.
7 ISO 15630-3 (2010), "Steel for the reinforcement and prestressing of concrete - Test methods - Part 3:prestressing steel", The International Organization for Standardization, Switzerland.
8 Kim, J.K., Lee, P.G. and Lee, M.S. (2010), "Development of 2,160MPa strand and application technology",Magazine of Korea Concrete Institute, 25(1), 68-70. (in Korean)
9 KS D 7002 (2011), "Uncoated stress-relieved steel wires and strands for prestressed concrete", Korean Standards Association, Seoul, Korea.
10 KS D 3752 (2007), "Carbon steel for machine structural use", Korean Standards Association, Seoul, Korea.
11 KS D 3867 (2007), "Low-alloy steels for machine structural use", Korean Standards Association, Seoul, Korea.
12 Kwon, S.H. and Shah, S.P. (2008), "Prediction of early-age cracking of fiber-reinforced concrete due to restrained shrinkage", ACI Materials Journal, 105(4), 381-389.
13 Kwon, S.H., Ferron, R.P., Akkaya, Y. and Shah, S.P. (2007), "Cracking of fiber-reinforced self-compacting concrete due to restrained shrinkage", International Journal of Concrete Structures and Materials, 1(1), 3-9.   DOI   ScienceOn
14 Loflin, B.J. (2008), "Bond and material properties of grade 270 and grade 300 prestressing strands", Master Degree Thesis at Virginia Polytechnic Institute and State University, Virginia, USA.
15 Noh, M.H., Seong, T.R. and Kim, J.K. (2012), "Nonlinear analysis of anchor head for high strength steel strand", COSEIK Journal, 25(2), 163-174.   과학기술학회마을   DOI   ScienceOn
16 Paik, I.Y., Shim C.S., Chung, Y.S. and Sang, H.J. (2011), "Statistical properties of material strength of concrete, re-bar and strand used in domestic construction site", Journal of the Korea Concrete Institute,23(4), 421-430. (in Korean)   과학기술학회마을   DOI   ScienceOn
17 Preston, H.K. (1985), "Testing 7-wire strand for prestressed concrete-the state of the art", PCI Journal, 30(3), 134-155.   DOI
18 Preston, H.K. (1990), "Handling prestressed concrete strand", PCI Journal, 35(6), 68-71.   DOI
19 PTI (1998), "Acceptance Standards for Post-Tensioning Systems", Post-Tensioning Institute, Phoenix, USA.
20 PTI (2012), "Recommendations for Stay Cable Design, Testing, and Installation", Post-Tensioning Institute, Phoenix, USA.
21 Seo, J.W., Jeong, W. and You, H. (2010), "Socket design and safety review on PPWS cable for suspension bridge", 2010 KSCE Conference Proceedings, 2517-2517. (in Korean)
22 Seo, J.W., Jeong, W., Cho, E.K. and You, H. (2010), "Parametric analysis to determine optimum geometries of PPWS sockets in cable-suspension bridges", 2010 KSCE Conference Proceedings, 35-36. (in Korean)
23 Setra (2009), "European Technical Approval No ETA-09/0068", Setra, Bagneux Cedex, France.
24 Setra (2006), "European Technical Approval No ETA-06/0006", Setra, Bagneux Cedex, France.
25 Terrasi, G.P., Affolter, C. and Barbezat, M. (2011), "Numerical optimization of a compact and reusable pretensioning anchorage system for CFRP tendons", Journal of composites for construction, 15(2), 126 -135.   DOI   ScienceOn
26 Walsh, K.Q. and Kurama, Y.C. (2012), "Effects of loading conditions on the behavior of unbonded posttensioning strand-anchorage systems", PCI Journal, 76-86.
27 Walsh, K.Q. (2009), "Behavior and design of unbonded post-tensioning strand/anchorage systems for seismic applications", Master Degree Thesis at University of Notre Dame, Indiana, USA.
28 Wang, X.H. and Liu, X.L. (2012), "Analysis of RC beam with unbonded or exposed tensile reinforcements and defective stirrup anchorages for shear strength", Computers and Concrete, 10(1), 59-78.   DOI   ScienceOn