• Title/Summary/Keyword: high-strength strand

Search Result 40, Processing Time 0.072 seconds

Bond Characteristics of PS Strand around the End Zones of High Strength Pretensioned Prestressed Concrete Members (고강도 프리텐션 프리스트레스트 콘크리트 부재 단부 영역에서의 PS 강연선 부착특성 연구)

  • 김동백;김의성
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.102-107
    • /
    • 2000
  • The extensive use of pretensioned prestressed concrete in the modem construction industry, together with wider application of pretensioned components for structural purposes requires some important consideration on the adequate transfer of prestress force into the concrete, especially around the end zones of pretensioned member. The main objective of this paper is to study the effects of various important parameters on the bond characteristics of prestressing strand around the end zone of high strength pretensioned concrete members. To this end, a comprehensive experimental program has been set up. The principal test variables considered were strand diameter, concrete strength, concrete cover size. The present study provides valuable test data for the realistic and accurate determination of transfer length, which can be efficiently used for improving the design equation of transfer length in pretensioned prestressed concrete members.

  • PDF

Investigation on Applicability of 2400 MPa Strand for Posttensioned Prestressed Concrete Girders (포스트텐션 PSC 거더에 대한 2400 MPa급 강연선의 적용성 분석)

  • Park, Ho;Cho, Jae-Yeol;Kim, Jee-Sang
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.727-735
    • /
    • 2012
  • Recently, a high-strength strand of 2400 MPa was developed using domestic technologies. In 2011, KS D 7002 was revised to cover the newly developed high-strength strands to support their practical usage. Presently, however, discussions and evaluations are not sufficient on the mechanical properties of the strands and their performance in structural members. Also, there were no detailed reviews on the need to revise the current design code for practical use of the high-strength strands. In this study, flexural behavior of a member with the high-strength strands was estimated through sectional analysis and a review and comparison of the domestic and foreign design codes were conducted considering the analysis results. Also, the need for the revision of the design code was discussed. Such discussion especially focused on the estimation of the stress in strand, which related with various issues such as determination methods for yield point of strands, time-dependent loss of prestressing force, estimation of stress in strand at member failure, and net strain limit for ductile failure of member. The discussion revealed that some parts in the design code need a revision and the further studies are required.

Nonlinear Analysis of Anchor Head for High Strength Steel Strand (고강도 강연선용 앵커헤드의 형상변화에 따른 비선형 거동특성 분석)

  • Noh, Myung-Hyun;Seong, Taek-Ryong;Kim, Jin-Kook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.2
    • /
    • pp.163-173
    • /
    • 2012
  • This study covers the nonlinear analysis of anchor head for high strength prestressing strand and presents necessary process in improving the performance of anchor head. The surface of wedge for strand is contacted to the surface of the wedge hole on anchor head when it is fitted into the wedge hole, and the contact condition changes according to the level of load applied through the wedge. In order to analyze detailed behavior, nonlinear material model and contact element were used in analysis. It was found from the analysis that the behavior of anchor head is affected by the interaction with the wedge contacted so that the wedge in FE model should have the same figure as the actual object. Circular array of wedge hole presents better stress distribution than layer array even though the small difference in maximum deformation. Increment of thickness of anchor head and distance of wedge hole also improve the performance of anchor head.

Characteristics of Thermal Degradation for Carbon Fiber/Epoxy Composite using Strand Specimen (스트랜드 인장시편을 적용한 탄소섬유/에폭시 복합재의 열화특성 연구)

  • Oh, Jin-Oh;Kil, Hyung-Bae;Yoon, Sung-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.408-410
    • /
    • 2012
  • In this study, High temperature properties of carbon fiber reinforced composites is performed using strand specimens and resin specimens. As for the tensile test at the different temperature, the tensile modulus of resin specimens decreases slightly until the temperature reaches the glass transition temperature. but the tensile modulus of strand specimens maintains tensile modulus at the room temperature. The tensile strength of resin and strand specimens decreases rapidly until the temperature reaches the glass transition temperature.

  • PDF

Study on the Tensile Strength Characteristics of CFRP under the High Temperature Condition (고온 환경하에서의 CFRP의 인장강도특성에 관한 연구)

  • Park Jae-Beom;Hwang Tae-Kyung;Kim Hyung-Geun;Doh Young-Dae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.86-89
    • /
    • 2006
  • In this research, the decrease of the tensile strength in CFRP was investigated by experimental and analytical methods. We focused on the role of the interface between the reinforcing fiber and the epoxy resin matrix. The tensile and the interface strengths in CFRF were evaluated using the strand and the short beam specimens. Curtin's model which correlate the mechanical strength of the interface to the tensile strength was introduced for analytical study. The experimental and the analytical results showed good coincidence and we found that the interface strength is the key factor which governs the CFRP's tensile strength.

  • PDF

Tensile behavior of new 2,200 MPa and 2,400 MPa strands according to various types of mono anchorage

  • Kim, Jin Kook;Seong, Taek Ryong;Jang, Kyung Pil;Kwon, Seung Hee
    • Structural Engineering and Mechanics
    • /
    • v.47 no.3
    • /
    • pp.383-399
    • /
    • 2013
  • High-strength strands are widely used as a key structural element in cable-stayed bridges and prestressed concrete structures. Conventional strands for stay cable and tendons in prestressed concrete structures are ${\phi}$15.7mm coated seven-wire strands and ${\phi}15.2mm$ uncoated seven-wire strands, respectively, but the ultimate strengths of both strands are 1860MPa. The objective of this paper is to investigate the tensile behavior of a newly developed ${\phi}15.7mm$ 2,200 MPa coated strand and a ${\phi}15.2mm$ 2,400 MPa uncoated strand according to various types of mono anchorages and to propose appropriate anchorages for both strands. Finite element analyses were initially performed to find how the geometry of the anchor head affects the interaction among the anchor head, the wedge and the strand and to find how it affects the stress distributions in both parts. Tensile tests for the new strands were carried out with seven different types of mono anchorages. The test results were compared to each other and to the results obtained from the tensile tests with a grip condition. From the analysis and the test results, desirable mono anchorages for the new strands are suggested.

Evaluation of Mechanical Property and Fatigue Damage in A Practical Superconducting Cable for Magnet (초전도 마그네트용 실용 초전도 복합선재의 기계적 특성 및 피로손상 평가에 관한 연구)

  • Sin, Hyeong-Seop;O, Sang-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.761-768
    • /
    • 2000
  • In order to investigate how the fatigue damage effects on the critical properties of superconductor, a fatigue test at room temperature and an Ic measurement test at 4.2K were carried out in this study, respectively, using a 9 strand Cu-Ni/NbTi/Cu composite cable. Through the fatigue test of a 9 strand Cu-NUNbTi/Cu composite cable, a conventional S-N curve was plotted even though there was a possibility of fretting among strands. It was found that the maximum stress corresponding to the inflection point on the S-N curve obtained was nearly the same value as the yielding strength of cable obtained from the static tensile test. However, the effect of cabling in multi-strands superconducting cable on the fatigue strength was not noticeable. The critical current(Ic) measurement was carried out at 4.2K in a NbTi strand out of the fatigued cable. It showed a degradation of lc at high stress amplitude regions over 380NTa, and the degradation became significant as the applied stress amplitude increased.

Manufacturing of fully impregnated prepreg tape and its applications (완전 함침된 프리프레그 테이프의 성형방법 및 응용분야)

  • Lee, Geon-Woong;Park, Min;Kim, Jun-Kyung;Choe, Chul-Rim;Lee, Jae-Shik;Jeong, Ho-Gap
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.245-248
    • /
    • 2002
  • Research on the high performance and strength thermoplastic/continuous fiber composites was performed. New concept of impregnating die for developing continuous strand and prepreg tape of engineering plastic/glass fiber was introduced and estimated. Fully impregnated prepreg strand and tape was successfully manufactured through the new pin structure of impregnating die and control of spreading variable. Also design variables for stability of increasing processing speed were shown. And tensile strength of prepreg tape manufactured in this study was much higher than composites made by other competition company.

  • PDF

Transfer length of 2400 MPa seven-wire 15.2 mm steel strands in high-strength pretensioned prestressed concrete beam

  • Yang, Jun-Mo;Yim, Hong-Jae;Kim, Jin-Kook
    • Smart Structures and Systems
    • /
    • v.17 no.4
    • /
    • pp.577-591
    • /
    • 2016
  • In this study, the transfer length of 2400 MPa, seven-wire high-strength steel strands with a 15.2 mm diameter in pretensioned prestressed concrete (PSC) beams utilizing high strength concrete over 58 MPa at prestress release was evaluated experimentally. 32 specimens, which have the variables of concrete compressive strength, concrete cover depth, and the number of PS strands, were fabricated and corresponding transfer lengths were measured. The strands were released gradually by slowly reducing the pressure in the hydraulic stressing rams. The measured results of transfer length showed that the transfer length decreased as the concrete compressive strength and concrete cover depth increased. The number of strands had a very small effect, and the effect varied with both the concrete cover depth and concrete strength. The results were compared to current design codes and transfer lengths predicted by other researchers. The comparison results showed that the current transfer length prediction models in design codes may be conservatively used for 2400 MPa high-strength strands in high-strength concrete beams exceeding 58 MPa at prestress release.

Experimental Investigation on Seismic Performance of RC Circular Columns Strengthened Using Highly-Ductile PET-AF Fiber Strand (고연성 PET-AF 스트랜드로 외부 보강한 RC 원형 기둥의 내진 성능에 관한 실험적 연구)

  • Chinzorigt, Gombosuren;Kim, So-Young;Choi, Donguk;Lim, Myung-Kwan;Lee, Chin-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.56-66
    • /
    • 2017
  • In this study, seismic strengthening performance of RC circular columns reinforced with high ductile PET and hybridized fibers(HF, PET + aramid) strand was experimentally compared and investigated. As a result, the maximum flexural strength and ductility capacity of all reinforced columns were improved than control column and fiber rupture did not occur at the ultimate stage. In addition, the resistive strength and displacement of the PET sheet 25 layers reinforcing column and the HF strand 1 layer reinforcing column were almost similar, so that 1 layer of HF strand showed the same lateral confinement effect as the PET sheet 25 layers. As a result of this experimental study, PET is considered to be suitable as seismic reinforcement material for RC structures in terms of flexural strength and ductility. However, in order to increase the possibility of application in the field, it is necessary to use a prefabricated PET sheet such as HF used in this study. The durability of PET needs investigation in the future.