• 제목/요약/키워드: high-strength shear reinforcement

검색결과 237건 처리시간 0.025초

축력과 반복횡력을 받는 고강도 R/C 기둥의 횡보강근 효과에 관한 실험적 연구 (An Experimental Study on the Effects of Lateral Reinforcement of High-Strength R/C Columns Subjected to Reversed Cyclic and Axial Forces)

  • 한범석;이지영;안종문;이광수;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.493-498
    • /
    • 1998
  • An experimental investigation was conducted to examine the behavior of high-strength concrete R/C columns subjected to moment, shear and axial load. The test parameters of specimens were the compressive strength of concrete(f'c=250, 516, 600kg/ ㎠), space of lateral reinforcement (20, 30, 37cm) and lateral reinforcement ratio(ρs=2.1, 3.15%). Test results indicated that compressive strength of concrete and lateral reinforcement can significantly affect and alter the behavior of column under inelastic cyclic loadings. Despite of the defaults of high-strength concrete, with increased amount of lateral reinforcement ratio to core concrete and added sub-lateral reinforcement, ductility and strength of RC columns used high-strength concrete can secured.

  • PDF

소성 이론에 의한 강섬유 보강 초고성능콘크리트의 전단 마찰 강도식 제안 (Shear Friction Strength based on Limit Analysis for Ultra-High Performance Fiber Reinforced Concrete)

  • 이지형;홍성걸
    • 콘크리트학회논문집
    • /
    • 제27권3호
    • /
    • pp.299-309
    • /
    • 2015
  • 강섬유 보강 초고성능 콘크리트(UHPFRC)는 뛰어난 압축 및 인장강도를 가지고 있는 재료이다. 일반 콘크리트는 균열 발생 후 균열에 수직으로 보강된 철근의 구속력을 수직항력으로, 구속력에 의해 발생하는 골재 맞물림 등에 의한 균열면의 거칠기를 마찰 계수로 표현하여 전단 마찰 강도를 정의하고 있다. UHPFRC는 골재 맞물림 현상은 없으나 강섬유의 부착응력에 의한 균열 후 인장력이 상당히 큰 특징이 있으며, 이러한 특징은 전단 마찰 강도에 반영되어야 함이 타당하다. 본 연구에서는 전단면에 횡철근이 보강된 24개의 직접 전단실험체를 제작하여 푸시 오프 실험을 수행하였다. 실험결과는 소성 이론에 의해 분석되었으며 이로부터 전단 마찰 계수와 유효 계수를 도출하였다. 소성 이론에 의한 전단 마찰 강도식은 기존 실험결과 및 기존 전단 마찰 강도식과 비교하여 타당성을 검증하였으며, 최종적으로 UHPFRC의 균열 후 인장강도를 고려한 일체식 구조체의 전단 마찰 강도식을 제안하였다.

Shear strength analysis and prediction of reinforced concrete transfer beams in high-rise buildings

  • Londhe, R.S.
    • Structural Engineering and Mechanics
    • /
    • 제37권1호
    • /
    • pp.39-59
    • /
    • 2011
  • Results of an experimental investigation on the behavior and ultimate shear capacity of 27 reinforced concrete Transfer (deep) beams are summarized. The main variables were percent longitudinal(tension) steel (0.28 to 0.60%), percent horizontal web steel (0.60 to 2.40%), percent vertical steel (0.50to 2.25%), percent orthogonal web steel, shear span-to-depth ratio (1.10 to 3.20) and cube concrete compressive strength (32 MPa to 48 MPa).The span of the beam has been kept constant at 1000 mm with100 mm overhang on either side of the supports. The result of this study shows that the load transfer capacity of transfer (deep) beam with distributed longitudinal reinforcement is increased significantly. Also, the vertical shear reinforcement is more effective than the horizontal reinforcement in increasing the shear capacity as well as to transform the brittle mode of failure in to the ductile mode of failure. It has been observed that the orthogonal web reinforcement is highly influencing parameter to generate the shear capacity of transfer beams as well as its failure modes. Moreover, the results from the experiments have been processed suitably and presented an analytical model for design of transfer beams in high-rise buildings for estimating the shear capacity of beams.

Pullout Test of Headed Reinforcing Bar in RC or SFRC Members with Side-Face Blowout Failure

  • Lee, Chang-Yong;Kim, Seung-Hun;Lee, Yong-Taeg
    • Architectural research
    • /
    • 제22권1호
    • /
    • pp.33-39
    • /
    • 2020
  • In this study, side-face blowout failure strength of high strength headed reinforcing bar, which is vertically anchoring between RC or SFRC members, is evaluated throughout pullout test. The major test parameters are content ratio of high strength steel fibers, strength of rebar, length of anchorage, presence of shear reinforcement, and the side concrete cover thickness planned to be 1.3 times of the rebar. In pullout test, tensile force was applied to the headed reinforcing bar with the hinged supports positioned 1.5 and 0.7 times the anchorage length on both sides of the headed reinforcing bar. As a result, the cone-shaped crack occurred where the headed reinforcing bar embedded and finally side-face blowout failure caused by bearing pressure of the headed reinforcing bar. The tensile strength of specimens increased by 13.0 ~26.2% with shear reinforcement. The pullout strength of the specimens increased by 3.6 ~15.4% according to steel fiber reinforcement. Increasing the anchoring length and shear reinforcement were evaluated to reduce the stress bearing ration of the total stress.

고강도 콘크리트를 이용한 철근콘크리트 기둥 부재의 연성평가에 관한 연구 (An Analytical Evaluation on the Ductility of Reinforced High-Strength Concrete Columns)

  • 장일영;송재호;한상묵;박훈규
    • 콘크리트학회논문집
    • /
    • 제12권3호
    • /
    • pp.57-66
    • /
    • 2000
  • The ductility is an important consideration in the design of reinforced concrete structures. In the seismic design of reinforced concrete columns, it is necessary to allow for relatively large ductilities that the seismic energy be absorbed without shear failure of significant strength degradation after the reinforcement yielding in columns. Therefore, prediction of the ductility should be as accurate as possible. This research investigate the ductile behavior of rectangular reinforced high-strength concrete columns like as bridge piers with confinement steel. The effects on the ductility of axial load, lateral reinforcement ratio, longitudinal reinforcement ratio, shear span ratio, and compressive strength of concrete were investigated analytically using layered section analysis. as the results, it was proposed the proper relationship between ductility and variables and formulated into equations.

고강도 콘크리트 전단벽의 강도와 변형능력 (Shear Strength and Deformability of HSC Shear Walls)

  • 윤현도;최창식;오영훈;이훈희
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.925-930
    • /
    • 2003
  • Provisions for ACI 318-02 and NZS 3101 pertaining to shear design of shear walls evaluated the applicability of high-strength, concrete shear walls subjected to lateral loads. Results of 73 tests of reinforced concrete shear walls were reviewed. Evaluation of test results conducted in Korea, England, America, Japan, and Australia for low-aspect ratio walls indicates that the nominal unit shear strength($\phi$=1.0) calculated using the provisions of ACI and NZS does not represent the observed shear strength well. Based on the limited database considered in this study, a reasonable lower bound to the shear strength of high-strength concrete shear walls is found to be $\sqrt[0.4]{f_{cu}}$ MPa. Similar to that of normal strength concrete walls, the rate of increase of the measured shear strength with $$\rho$_n/ㆍf_y$ is less than 1.0. Therefore, the rate of increase of shear strength attributable to the web reinforcement in shear walls appears to be overestimated by the modified truss analogy.

  • PDF

전단보강재의 정착성능을 고려한 슬래브-기둥 내부접합부의 뚫림전단강도 (Punching Shear Strength of Slab-Column Interior Connection Considering Anchorage Performance of Shear Reinforcements)

  • 정형석;최현기;정주홍
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권2호
    • /
    • pp.51-58
    • /
    • 2022
  • 플랫 플레이트는 매우 경제적인 구조시스템으로서 고층건물과 아파트, 지하 주차장등에 널리 쓰인다. 하지만 기둥-슬래브 접합부가 뚫림전단에 취약하기 때문에 건물의 연쇄붕괴로 이어질 수 있는 단점이 있다. 이에 본 연구에서는 뚫림전단강도 증가, 연성능력 향상, 시공성면에서 뛰어난 나선형 철근 전단 보강재가 제안되었으며, 실험을 통해 나선형 철근 전단보강재의 강도를 평가하였다. 현행 기준은 전단보강된 슬래브-기둥 접합부의 뚫림전단강도를 정확하게 예측하지 못하고 있다. 그 이유는 전단보강재가 설치되는 슬래브의 두께가 얇을경우 정착길이가 확보되지 못하여 전단보강재가 항복강도에 이르기 전에 파괴가 일어나기 때문이다. 이에 본 연구에서는 유한요소해석 프로그램 LUSAS ver14.3을 이용하여 나선형 전단보강재의 보강성능에 영향을 미치는 변수를 분석하여 강도보정계수를 도출하였다. 또한 CEB-FIP 데이터뱅크에 수록된 실험체의 회귀분석을 통해 전단보강된 슬래브-기둥 접합부의 뚫림전단강도 산정식을 제안하였다.

Repair of precracked RC rectangular shear beams using CFRP strip technique

  • Jayaprakash, J.;Samad, Abdul Aziz Abdul;Abbasovich, Ashrabov Anvar;Ali, Abang Abdullah Abang
    • Structural Engineering and Mechanics
    • /
    • 제26권4호
    • /
    • pp.427-439
    • /
    • 2007
  • The exploitation of fibre reinforced polymer composites, as external reinforcement is an evergreen and well-known technique for improving the structural performance of reinforced concrete structures. The demand to use FRP composites in the civil engineering industry is mainly due to its high strength, light weight, and stiffness. This paper exemplifies the shear strength of partially precracked reinforced concrete rectangular beams repaired with externally bonded Bi-Directional Carbon Fibre Reinforced Polymer (CFRP) Fabrics strips. All specimens were cast in the laboratory environment without any internal shear reinforcement. The test parameters were longitudinal tensile reinforcement, shear span to effective depth ratio, spacing of CFRP strips, and orientation of CFRP reinforcement. It mainly focuses on the shear capacity and modes of failure of the CFRP strengthened shear beams. Results have shown that the CFRP repaired beams attained a shear enhancement of 32% and 107.64% greater than the control beams. This study underscores that the CFRP strip technique significantly enhanced the shear capacity of precracked reinforced concrete rectangular beams without any internal shear reinforcement.

최소 전단철근 대용으로의 강섬유 콘크리트의 전단기여도 평가 (Evaluation on Shear Contribution of Steel Fiber Reinforced Concrete in Place of Minimum Shear Reinforcement)

  • 김철구;박홍근;홍건호;강수민
    • 콘크리트학회논문집
    • /
    • 제27권6호
    • /
    • pp.603-613
    • /
    • 2015
  • 현행 콘크리트 구조기준에는 전단파괴의 취성적 특성을 고려하여 휨 부재에 최소전단철근을 배근하도록 규정하고 있고, 강섬유 보강 콘크리트 사용시 강섬유가 최소전단철근을 대신하여 사용가능하도록 허용하고 있다. 본 연구에서는 이러한 최소전단철근과 강섬유가 전단강도에 미치는 영향을 단순지지 보 실험을 통해 분석하였다. 실험결과를 살펴보면, 강섬유 보강이 최소 전단철근보다 전단강도에 미치는 영향이 크게 나타났고 특히, 고강도콘크리트가 사용된 경우 강섬유 효과가 크게 발휘되었다. 강섬유 콘크리트의 특성을 살펴보기 위해 기존 실험 자료를 분석하였고 현행 기준에 사용되고 있는 최소전단철근 대용으로의 강섬유 보강 콘크리트 보의 적절성을 평가하였다.

Shear Strength Prediction by Modified Plasticity Theory for High-Strength Concrete Deep Beams

  • 조순호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.494-497
    • /
    • 2004
  • This paper presents the analysis results predicted by the upper bound approach in the limit analysis of concrete incorporating the original plastic and crack sliding solutions for short high-strength concrete beams that varied the compressive strength of concrete, and the shear span-to-depth and vertical shear reinforcement ratios. The significance of the distance away from the support to define the location where the yield line starts and the properties of cracked concrete, particularly related to high-strength concrete, is identified.

  • PDF