• 제목/요약/키워드: high-strength concrete high-rise building

검색결과 159건 처리시간 0.021초

Structural Design of an Ultra High-rise Building Using Concrete Filled Tubular Column with 780 N/㎟ Class High-strength Steel and Fc150 N/㎟ High-strength Concrete

  • Matsumoto, Shuichi;Hosozawa, Osamu;Narihara, Hiroyuki;Komuro, Tsutomu;Kawamoto, Shin-ichiro
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.73-79
    • /
    • 2014
  • In recent years, the performance requested for which an ultra-high rise buildings is diversified. Large spans are designed in order to gain wide workspace. Column positions are shifted in middle stories to provide space different from neighboring floors. Moreover, in the bottom layers of the building, it is becoming more important to expand freedom to plan flexibility such as creating publically opened wide atria that gives attractive free space. Earthquake-proof criteria is also changing not only human life protection deign but also a design that allows functional continuity. In order to achieve thee needs, as one of technology, we have developed ultra-high strength concrete filled tubular (CFT) columns of the box section that combine ultra-high strength concrete with specified strength of $150N/mm^2$ and ultra-high strength steel material with tensile strength of $780N/mm^2$. In this paper, the outline of development of an ultra-high strength CFT column is reported. Also, the structural design of the ultra-high-rise building using the CFT columns is reported.

전자기장을 활용한 초고층 건축물 콘크리트 압송기술개발 (Development of concrete pumping technology for construction of high-rise building using electromagnetic field)

  • 김우재;권승희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.4-5
    • /
    • 2018
  • Recently, high-strength concrete used for shortening the construction time of high-rise building construction, Concrete pumping technology is emerging as the core technology of high-rise buildings. In this paper, we have started to study the use of electromagnetic field as a method to increase the efficiency of the lubricating layer between the inside of the pipe and concrete, which has been established as the most important factor determining the pumping performance. The pumping performance improvement effect of concrete strength was verified and basic research was carried out to utilize it as a method to increase the efficiency of pumping in field application. In the related work, the effect of the electromagnetic field was verified by conducting a mock-up performance evaluation (horizontal 300 m) of the pumping force by the concrete strength.

  • PDF

초고층 건축물에서 고강도 콘크리트의 강도 및 압송높이 변화에 따른 펌프 압송 전·후의 물성평가 (Properties of High Strength Concrete before and after Pumping in Response to Strength Level and Pumping Height)

  • 정상운;이홍규;조만기;김규동;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.274-275
    • /
    • 2014
  • As the increase amount of high rise building, equipments for high rise building have been extensively studied. However quality problems caused as the pumping of concrete including loss of flowalility, air content and increasing of the temperature. In this study, fundamental performances of the 80 MPa concrete before·after pumping has been tested. Results showed slump flow increased after pumping temperature of concrete also increased after pumping. Results also shown air content all satisfied the target range and compressive strength of concrete increased about 20 % after pumping, All the performances satisfied the standard for 80 MPa.

  • PDF

콘크리트 충전강관구조(CFT) 적용을 위한 일반강도 콘크리트 물성에 관한 실험적 연구 (A Study on Characteristics of Normal Strength Concrete adapted to Concrete Filled Steel Tube)

  • 강동현;강용학;정근호;이영도;이장오
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.46-51
    • /
    • 2001
  • As a rule, in case of CFT for high-rise building, high strength concrete is required since it should have high fluidity, segregation resistance and large proportion of cement per unit considering the fi11ing beneath the diaphragm. However, regarding the low-rise building under 20 stories, it is somewhat difficult to use high strength concrete. This is a fundamental study to develop a concrete with normal strength and high fluidity for CFT of low-rise building, whose purposes are in speculating several kinds of changes in concrete's characteristics through various experiments and offering basic documents for practicalization in si to and production through mock-up test.

  • PDF

초고강도 콘크리트의 물리적·역학적 특성에 관한 실험적 연구 (An Experimental Study on the physical-mechanical Properties of Ultra-High-Strength-Concrete)

  • 박희곤;이진우;배연기;김우재;이재삼;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.107-111
    • /
    • 2008
  • As high-rise buildings with 100 or more stories are being constructed, it is inevitable to use high-performance materials including high-performance concrete. What is most important in high-performance concrete is extremely high strength in order to reduce the section of members in high-rise buildings. During the last several years, there have been active researches on Ultra-high-strength concrete. While these researches have been mostly focused on strength development, however, other accompanying physical properties have not been studied sufficiently. Thus, this study purposed to obtain and analyze data on the physical-mechanical properties of Ultra-high-strength concrete through experiments and to use the results as basic information on required performance of concrete used in high-rise buildings.

  • PDF

Transition Analysis of Friction Factor According to Pumping Pressure in Pumping Test Using High Strength Concrete for High-rise Buildings

  • Kwon, Hae-Won;Kim, Young-Su
    • 한국건축시공학회지
    • /
    • 제13권4호
    • /
    • pp.400-406
    • /
    • 2013
  • In high-rise buildings, high-strength concrete is widely used to reduce the section of structure members under axial load. Also, the price increase of materials is very important item in the high-rise buildings. Especially, concrete used high-pressure pump due to consecutive structural assembly. Unlike slump type of ordinary concrete, high strength concrete has different properties of concrete pumping due to viscosity. However, there have been no Korean studies on the pumping properties of high strength concrete. Therefore, this paper measures the friction factor of high strength concrete with changes in the pressure of concrete pumping. We analyzed the trends of the friction factor based on changes in the pressure of concrete pumping, and then calculated the quantity of concrete deposited for each specified concrete strength and location of placement. After comparing these results with the quantity of concrete deposited measured in field, we evaluated the pumping properties of high strength concrete. Through the tests and the review, we attempt to suggest some basic information for the In-Situ application of high strength concrete.

콘크리트 충전강관구조(CFT) 적용을 위한 일반강도 콘크리트 물성에 관한 실험적 연구 (A Study on Characteristics of Normal Strength Concrete adapted to Concrete Filled Steel Tube)

  • 강동현;강용학;정근호;김우재;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1071-1076
    • /
    • 2001
  • As a rule, in case of CFT for high-rise building, high strength concrete is required since it should have high fluidity, segregation resistance and large proportion of cement per unit considering the filling beneath the diaphragm. However, regarding the low-rise building under 20 stories, it is somewhat difficult to use high strength concrete. This is a fundamental study to develop a concrete with normal strength and high fluidity for CFT of low-rise building, whose Purposes are in speculating several kinds of changes in concrete's characteristics through various experiments and offering basic documents for practicalization in site and production through mock-up test.

  • PDF

비재하 내화시험에 의한 섬유혼입 고강도 콘크리트 Mock-up 기둥의 내화성능 평가 (Evaluation of Fire Performance for High Strength Concrete Mock-up Column with Fiber by Unloaded Fire Test)

  • 송영찬;김용로;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.97-100
    • /
    • 2009
  • Fire resistance properties and mechanical properties of high strength concrete mock-up column using organic fiber by KS F 2257 Methods of fire resistance test for elements of building construction and compression test was investigated for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

폴리프로필렌 및 비닐론 섬유를 혼입한 고강도콘크리트의 내화특성 (Fire Resistance of High Strength Concrete with Polypropylene and Vinylon Fiber)

  • 남지현;오상균;김정길
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.165-169
    • /
    • 2005
  • The fire damage of building wouid effect on the safety of structure. When the reinforced concrete structure is heated by high temperature due to the fire, the structural resisting-force will be decreased. In a way, it is a requirement to use high strength concrete for high rise building. Particularly, fire resistance properties of high-strength concrete is more important than normal strength concretes. The fire outbreak of a high strength concrete by sudden temperature rise is a main problem, and causes crack by thermal stress, loading to the deterioration of the durability. In this study, normal and high strength mortar were exposed to a high temperature environment. And than fundamental data for the character change of concrete heated highly were presented by measuring compressive strength of concrete with polypropylene and vinylon fiber, before and after heating. As the results, it is proven that high strength mortar with polypropylene and vinylon fiber for prevents deterioration of durability by fiber.

  • PDF

서중환경의 단열온도상승 특성을 고려한 고강도 콘크리트의 압축강도 특성 (Compressive Strength Properties of high strength concrete considering Adiabatic temperature rise of hot weather environment)

  • 이은경;함은영;구경모;이보경;미야우치 히로유키;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.56-57
    • /
    • 2013
  • In this study, in regard to concrete considering variety of admixture content rate, we evaluated property of adiabatic temperature rise. By setting up high temperature history, we evaluated effect to compression strength property of high strength concrete by early high temperature history. As a result, early high temperature history accelerated Hydration reaction of cement and contribute early strength development but it didn't accomplish performance objective in long-term aged.

  • PDF