• Title/Summary/Keyword: high-rise construction

Search Result 999, Processing Time 0.025 seconds

Case Study on Mega Foundations of Domestic and Foreign Super High-Rise Buildings (국내외 초고층 건축물의 대단면 매트기초 시공사례와 분석)

  • Park, Young-Seok;Lee, Hai-Chool;Kim, Kyoung-Min;Cho, Chang-Shik;Rhim, Hong-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.17-19
    • /
    • 2010
  • This paper describes the possibility of the raft thickness reduction for mega foundations system of super high-rise buildings through a case study on domestic and foreign super high-rise buildings. In case of super high-rise buildings, the size of foundations, especially raft becomes wider and deeper because of heavy upper load. It is difficult to pour concrete of this kind of mega foundation, and cracks by hydration heat could happen. Therefore, there are several ways to reduce the raft thickness of mega foundations. Piled-raft could be the one because moment and shear load that the raft subjects on by soil reaction are lower. The effect of the piled-raft foundation on the raft thickness reduction could be confirmed by comparison of super high-rise buildings with pile, piled-raft and mat foundation. Furthermore, it was showed that the raft thickness could be more reduced by locating piles right under the vertical members of super structures.

  • PDF

A Study on the Parametric Design Process for Form Generation to Review Planning Factors of Irregular-Shaped High-rise Buildings (비정형 초고층건물의 계획요소 검토가 가능한 형태생성 파라메트릭 디자인 프로세스에 관한 연구)

  • Im, Ja-Eun;Park, Sang-Min
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.161-168
    • /
    • 2019
  • The use of various digital tools makes freeform modeling possible. At the same time, with the development of structural and construction technologies, Free-Form Architecture are beginning to be implemented realized, as the desired data extraction such as the size and coordinate points of the members is possible. Currently, in many cities around the world, Irregular-Shaped High-rise Buildings, which express the dynamic symbolism, are recognized for their landmark values. In order to realize the Irregular-Shaped High-rise Buildings, it is necessary to understand various fields such as the characteristics of digital tools, digital technique logic, design process, and construction method. In particular, it is important to plan Irregular-Shaped High-rise Buildings so that the various types of efficiency can be reviewed together, while generating understanding and formations from the initial design stage. Therefore, this study uses conceptual and parametric design tools related to form generation in digital architecture to analyze the details, methods, and characteristics of the Irregular-Shaped High-rise Buildings form generation process. In this paper, the parametric design tool is applied to study the various types of design and the process characteristics that can be considered in the initial design stage of the unstructured skyscraper.

A Preliminary Study on the Analysis of Constructability Issues in High-Rise Office Buildings (고층사무소 프로젝트의 시공성 항목 분석에 관한 기초연구)

  • Kwon Dong-Hyuk;Kim Han-Soo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.235-238
    • /
    • 2002
  • The successful completion of a construction project requires a thorough understanding of all stages and phases of the project, and enhanced through integration of design and construction during the pre-construction stage. Constructability is a major factor in measuring the success or failure of construction project. During the pre-construction stage, lack of construction knowledge integration in the planning and design process is a major factor that leads to constructability problems during the construction stage. this study is to find out such problems based on interview and questionnaire in the structure's work of High-Rise Office Buildings. The objective of this study is to Identify Impact aspect of the structure's work of High-Rise Office Buildings.

  • PDF

Case Study of 4D CAD Modeling in Hi-Rise Complex Buildings Project (초고층 복합시설물의 4D CAD 모델링 사례연구)

  • Kwan Oh-Sung;Park Woo-Yul;Cho Hun-Hee;Kang Kyung-In
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.187-192
    • /
    • 2001
  • High-Rise Building Construction Project which has high uncertainty and complexity, causes lots of problems under construction. In particular, the integration between design phase and construction phase highly affects a construction project in terms of cost and time. To possibly make the flexible response and preliminary verification against the construction planning problems in high rise building project, this paper proposes the Engineering-Construction Management System based on 4D CAD that put the time factor together with 3D CAD. The usefulness of this system has been verified through the actual project. It could helps the reducing trials and errors during construction phase by catching the factors on problems of project. Ultimately it will allow users to save project cost and duration by field application.

  • PDF

Reasonable Demolition Method Combination of RC Structures (RC구조물의 해체공법 조합방안)

  • Kim, Se-Bum;Yang, Jin-Kook;Lee, Sang-Beom
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.177-178
    • /
    • 2016
  • The main structure of the building has been used reinforced concrete construction method in Korea. In recent years, it is necessary to demolition of buildings into urban redevelopment. But yet the demolition method is not being developed perfect. It is necessary to develop future deconstruction for safety and environment method. In this study, we surveyed the demolition method has been used in domestic construction. How the combination of these demolition method should be needed. Demolition method combinations were classified as low-rise, high-rise, middle. It suggested method to combine the demolition process of reinforced concrete structure with seven.

  • PDF

An Application of Construction Sequence Analysis for Checking Structural Stability of High-Rise Building under Construction (초고층 건물의 시공 중 구조적 안정성 검토를 위한 시공단계해석의 적용)

  • Eom, Tae-Sung;Kim, Jae-Yo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.3
    • /
    • pp.211-221
    • /
    • 2009
  • With recent trends of super-tallness, atypical plan shapes and zoning constructions in high-rise buildings, a structural stability of the building under construction is arising as a key issue for design and construction plan. To ensure the structural stability under construction, the differential column shortening of vertical members, the lateral displacement of tower frames, and differential settlement of raft foundation by unbalanced distributions of a tower self-weight before the completion of a lateral load resisting system should be checked by construction sequence analysis, which should be performed by systematic combinations with structural health monitoring, construction compensation program, and construction panning. This paper presents the scheme of zone-based construction sequence analysis by using the existing commercial analysis program, to check the stability of high-rise building under construction. This scheme is applied to 3-dimensional structural analysis for a real high-rise building under construction. The analysis includes real construction zoning plans and schedules as well as creep and shrinkage effects and time-dependent properties of concrete. The simplified construction sequence and assumed material properties were continuously updated with the change on construction schedule and correlations with in-situ measurement data.

Evaluation of Fire Performance for High Strength Concrete Mock-up Column with Fiber by Unloaded Fire Test (비재하 내화시험에 의한 섬유혼입 고강도 콘크리트 Mock-up 기둥의 내화성능 평가)

  • Song, Young-Chan;Kim, Yong-Ro;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.97-100
    • /
    • 2009
  • Fire resistance properties and mechanical properties of high strength concrete mock-up column using organic fiber by KS F 2257 Methods of fire resistance test for elements of building construction and compression test was investigated for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

The Residential Satisfaction of Residents in High-rise Mixed-use Apartments (초고층 주상복합아파트 거주자의 주거만족도)

  • 강순주;이수현
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.6
    • /
    • pp.1-12
    • /
    • 2004
  • This study investigates residents' living satisfaction with high-rise, mixed-use apartments built in the structures of reinforced concrete construction(RC) and with steel framed, reinforced concrete construction(SRC). The following study results were obtained: 1) Residents expressed below average satisfaction (below 3.0) with the common-area landscape and environmentally-friendly factors, children's playground and its facilities, community service for residents' by the management offices and utility plan. 2) According to the satisfaction of sound environment, residents of the SRC group expressed above average satisfaction. It can be concluded that noise problems around the residential area of the SRC group was well solved in this study. However, the residents of the SRC group expressed low satisfaction with the freshness of indoor air, humidity, and smell in the living quarters. 3) High-rise, mixed-use apartments should accommodate a familial life cycle, be designed as an environmentally friendly resting place in harmony with city life, and provide various communal programs for residents.

A Study of DB System Establishment for Facility Management of High-Rise Mixed-use Building in Urban Regeneration (도시재생사업에서 초고층 주상복합시설의 유지관리를 위한 DB System 확립에 관한 연구)

  • Park, Jae-Hyun;Cho, Yong;Park, Won-Ho;Oh, Jung-Keun;Paek, Joon-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.177-181
    • /
    • 2008
  • Recently, amount of High-Rise Mixed-use Building is Increasing based on Preference of comfortable residence and good view. Government policies were turned to prefer about High-Rise Mixed-use Building because of decreased real estate Condition. But these changes have revealed that it has many maintenance problems for example- efficiency, economic, environmental problems. This paper suggests that the Database System based on various alternatives and real case. And it will be a tool in the scientific decision and value analysis from the facility management to make optimized decision.

  • PDF

A Study on the Fire Safety Design Methods of Opening in High-rise Building (초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF