• Title/Summary/Keyword: high-quality process

Search Result 3,663, Processing Time 0.038 seconds

Adjustment of Control Limits for Geometric Charts

  • Kim, Byung Jun;Lee, Jaeheon
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.5
    • /
    • pp.519-530
    • /
    • 2015
  • The geometric chart has proven more effective than Shewhart p or np charts to monitor the proportion nonconforming in high-quality processes. Implementing a geometric chart commonly requires the assumption that the in-control proportion nonconforming is known or accurately estimated. However, accurate parameter estimation is very difficult and may require a larger sample size than that available in practice in high-quality process where the proportion of nonconforming items is very small. Thus, the error in the parameter estimation increases and may lead to deterioration in the performance of the control chart if a sample size is inadequate. We suggest adjusting the control limits in order to improve the performance when a sample size is insufficient to estimate the parameter. We propose a linear function for the adjustment constant, which is a function of the sample size, the number of nonconforming items in a sample, and the false alarm rate. We also compare the performance of the geometric charts without and with adjustment using the expected value of the average run length (ARL) and the standard deviation of the ARL (SDARL).

A Case Study on Application of R&D Quality Assurance to Secure High Quality for Military Supplies (군수품의 고품질 확보를 위한 개발 품질보증 적용사례 연구)

  • Choi, Chang-Hyun
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.1
    • /
    • pp.151-162
    • /
    • 2019
  • Purpose: This study is in order to secure high quality of military supplies, it is important to secure design quality in the development phase. I will review how to establish a quality assurance system in the development phase based on the author's seminar presentation contents and application example of Hanwha Systems Co., Ltd. Methods: To guarantee design quality in the development phase, in 2002, quality assurance system that is adequate for SQA(Software Quality Assurance)'s requirements of CMM(Capability Maturity Model) was conduct. In 2009, based on the CMMI(Capability Maturity Model Integration) Level 5, there has been continuous and reenforced quality assurance activities. Results: By suggesting the construction and a case study on application of R&D quality assurance, it would be helpful for companies aiming to construct or enhance quality assurance system. Conclusion: To secure high quality for military supplies, a development QA system should be established to secure quality in the development phase. In addition, Total life cycle QA system for development, mass production and operation phase should be reestablished.

Clinical Dental Hygiene Education and Practice based on Dental Hygiene Process (치위생 과정 기반의 임상 치위생 교육과 실무)

  • Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.11 no.3
    • /
    • pp.135-154
    • /
    • 2011
  • Dental hygiene was originated from dentistry and dental hygiene knowledge was a component of dental knowledge body. Since the late 1980s dental hygiene theory was began to develop. Nursing theories such as metaparadigm, nursing process and human need theory affected theory development as dental hygiene process. Dental hygiene process provides a framework for high quality dental hygiene care. Dental hygiene process include five phases; assessment, dental hygiene diagnosis, dental hygiene planning, implementation, evaluation. Dental hygiene process of care is recognized as standard for dental hygiene education and clinical dental hygiene practice. Dental hygiene practice has moved from auxiliary model to professional model. Critical thinking skill and disposition are necessary to provide evidence-based dental hygiene care using dental hygiene process as clinical process and critical thinking process. Critical thinking, problem solving and evidence-based practice must be integrated into dental hygiene process for quality dental hygiene care.

Evaluation of Sound Quality for Ergonomic Design of Movable Parts in a Refrigerator (냉장고 동작부품의 소음특성 분석을 통한 감성품질 개선)

  • Kang, Seong Yeop;So, Sae Rom;Kim, Gun Ou;Kim, Ji Hoon;Park, Sang Hu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.7-15
    • /
    • 2018
  • We propose a method for evaluating sound quality quantitatively to develop high-level home appliances (HA). Generally, a refrigerator has diverse movable parts such as slider, drawer, and folding shelf. Therefore, an engineering treatment to control the noise quality is considered as one of key technologies for a higher level refrigerator. Among the movable parts, we have selected a folding shelf as an example, which is commonly setup inside of a home refrigerator for increasing space convenience, to control the noise quality. However, it is known that its noise level is very high comparing to other movable parts when folding or unfolding actions. In order to evaluate and compare the noise quality, we have tested different eighteen models, and have suggested an impact sound quality index (ISQI) based on subjective evaluation data obtained experimentally by thirty two evaluators. The ISQI was formulated using three sound quality elements (noise peak, raising time, impact duration) to determine psycho-acoustic properties. Through this work, we developed an evaluating process and ISQI that was verified the usefulness by comparing the test results of personal perceptions given by evaluators with the prediction value of ISQI. We showed a good relations between them, so we believe that the proposed method and ISQI can be utilized to control of the noise quality of HA effectively.

Improvement for Chromaticity Coordinate Quality of Automotive White LED Packages (차량용 백색 LED 패키지의 색 좌표 품질 개선)

  • So, Soon Jin;Jeoung, Choung Woo;Moon, Tae Eul;Kim, Jeong Bin;Hong, Sung Hoon
    • Journal of Korean Society for Quality Management
    • /
    • v.50 no.3
    • /
    • pp.425-440
    • /
    • 2022
  • Purpose: The purpose of this paper is to improve the chromaticity coordinate quality of white LED packages for automobiles that require high quality and reliability. Methods: The project follows the structured methodology of the Six Sigma DMAIC Roadmap, which consists of Define, Measure, Analyze, Improve and Control phases. Results: A CTQ is determined based on COPQ analysis, and a process map and a XY matrix are utilized for selecting process input variables. Three vital Few Xs are identified through data analysis; amount to mix at one time, deviation by head pumps, and deviation by production magazines, and process improvements are performed for each of the three vital Few Xs. Conclusion: The improved process conditions for the three vital Few Xs are applied to the production line, and the results show that the percent defective of chromaticity coordinate has improved from 1.59% to 0.63% and a financial effect of about 50 million won per year is obtained.

Feasibility study on developing productivity and quality improved three dimensional printing process

  • Lee, Won-Hee;Kim, Dong-Soo;Lee, Taik-Min;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2160-2163
    • /
    • 2005
  • Solid freeform fabrication (SFF) technology plays a major role in industry and represents a reasonable percentage of industrial rapid prototyping/tooling/manufacturing (RP/RT/RM) development applications. However, SFF technology still has long way to progress to achieve satisfactory process speed, surface finish and overall quality improvement of its application. Today, three dimensional printing (3DP) technique that is one of SFF technology is receiving many interests, and is applied by various fields. It can fabricate three dimensional objects of solid freeform with high speed and low cost using ink jet printing technology. However, need long curing time after manufacture completion. And it must do post-processing process necessarily to heighten strength of objects because strength of fabricated objects is very weak. Therefore, in this study, we proposed an improved 3DP process that can solve problems of conventional 3DP process. The general 3DP process is method to spout binder simply through printer head on powder, but proposed process is method to cure jetted UV resin by UV lamp after jet UV resin using printhead on powder. The hardening of resin is achieved strongly at early time by UV lamp in proposed method. So, the proposed process can fabricate three dimensional objects with high speed without any post-processing.

  • PDF

Determinationof Optimal Cutting Condition for High Quality Cutting Surface (표면품질 향상을 위한 레이저 절단조건)

  • 황경현
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.37-41
    • /
    • 1990
  • The quality of cutting surface such as surface roughness, heat affected zone, serf width can be improved by controlling the parameters of cuting process. These parameters includes cutting velocity, laser beam power, material depth and assistant gas. Thermodynamic analysis and systematical experiments are attempted to pedict and determine the optimal cutting condition. There exists the optimal cutting condition to ensure high quality surface. Under this operation, the minimum surface roughness of the mild steel, the stainless steel and the titanium becomes 3.8${\mu}{\textrm}{m}$ 13${\mu}{\textrm}{m}$ and 10${\mu}{\textrm}{m}$ respectively.

  • PDF

Controlling of the heterogeniously growing GaN polycrystals using a quartz ring in the edge during the HVPE-GaN bulk growth

  • Park, Jae Hwa;Lee, Hee Ae;Park, Cheol Woo;Kang, Hyo Sang;Lee, Joo Hyung;In, Jun-Hyeong;Lee, Seong Kuk;Shim, Kwang Bo
    • Journal of Ceramic Processing Research
    • /
    • v.19 no.5
    • /
    • pp.439-443
    • /
    • 2018
  • The outstanding characteristics of high quality GaN single crystal substrates make it possible to apply the manufacture of high brightness light emitting diodes and power devices. However, it is very difficult to obtain high quality GaN substrate because the process conditions are hard to control. In order to effectively control the formation of GaN polycrystals during the bulk GaN single crystal growth by the HVPE (hydride vapor phase epitaxy) method, a quartz ring was introduced in the edge of substrate. A variety of evaluating method such as high resolution X-ray diffraction, Raman spectroscopy and photoluminescence was used in order to measure the effectiveness of the quartz ring. A secondary ion mass spectroscopy was also used for evaluating the variations of impurity concentration in the resulting GaN single crystal. Through the detailed investigations, we could confirm that the introduction of a quartz ring during the GaN single crystal growth process using HVPE is a very effective strategy to obtain a high quality GaN single crystal.

A Study on Corrosive Characteristics of Inconel 625 for Petroleum Application by FCAW Process (석유시추용 인코넬 625강의 FCAW용접에 의한 부식성에 관한 연구)

  • PARK KEYUNG-DONG;AN DO-KEYUNG;AN JAE-PIL
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.365-369
    • /
    • 2004
  • Recently, Inconel 625 is used widely in offshore processing piping in order to extend the maintenance tenn and improve the quality of anti-corrosion. According to the resistance to attack in various corrosive media at temperatures from $200^{\circ}C$ to aver $1090^{\circ}C$, in combination with good low- and high-temperature mechanical strength. In general, High quality weldments for this material are readily produced by commonly used processes. in recent years, the flux cored arc welding(FCAW) process is becoming more popular due to higher deposition rate and a better weld quality as compared to the shielded metal arc welding (SMAW) process, at the same time, exhibiting equally good weld metal toughness similar to the SAW process. In this study, the weldability and weldment characteristics(mechanical properties and corrosive environment) of Inconel 625 are considered in FCAW weld associated with the several weld shielding gases($80\%Ar\;+\;20\%\;CO_2,\;50\%Ar\;+\;50\%\;CO_2,\;100\%\;CO_2$) in viewpoint of welding productivity.

  • PDF

An Empirical Study of Comprehensive Health Screening Medical Service Quality with Kano Model and PCSI Index (Kano 모델 및 PCSI 지수를 활용한 종합건강검진 의료서비스 품질에 대한 실증적 연구)

  • PARK, Ae-Jun
    • The Journal of Industrial Distribution & Business
    • /
    • v.10 no.7
    • /
    • pp.71-82
    • /
    • 2019
  • Purpose - This study aims to identify the priorities of medical service quality improvement by customer satisfaction characteristics and potential customer satisfaction improvement (PCSI) index based on the dualistic quality classification of Kano Model (1984) for Comprehensive Health Screeening Center in General Hospitals and Centers only for Comprehensive Health Screening and suggest a direction for future improvement. Research design, data, and methodology - Through advanced research on health screening medical service quality, this study set four service quality factors, including tangible, human, process and supportive factors, and 39 measurement items. Based on these items, the study used 117 questions, which consist of dualistic quality factors, customer satisfaction coefficients, positive and negative questions for PCSI index and questions for current satisfaction. 300 effective samples were collected for adults in their 20s who experienced health screening service in Seoul, Gyeonggi-do and Incheon within the past two years. Collected data were input in the quality evaluation duality table to categorize quality factors and calculate customer satisfaction coefficients by Timko(1993). The study also analyzed PCSI index in comparison with current satisfaction and identified priorities in quality improvement. Results - It was found that the most urgent factors to improve the quality in both groups were adequate waiting hours and emergency response for complications, which are process factors classified as unitary quality. It is urgently needed to improve the quality as the PCSI index was high in supportive factors (complaint response team) as attractive quality in Comprehensive Health Screening Center in General Hospitals and in process factors (prevention of infection) as unitary quality in Centers only for Comprehensive Health Screening. As the PCSI index was low in space use as a tangible factor, it was found that the current level can be maintained instead of improvement. Conclusions - To improve the health screening medical service quality, it is required to focus on process factors (adequate waiting hours, emergency response for complications, prevention of infection) and supportive factors (complaint response team) among service qualities perceived by users. It is proposed to ensure continuous efforts to manage and reinforce priorities as a direction for future improvement in health screening service.