• Title/Summary/Keyword: high-magnification

Search Result 174, Processing Time 0.038 seconds

A planetary lensing feature in caustic-crossing high-magnification microlensing events

  • Chung, Sun-Ju;Hwang, Kyu-Ha;Ryu, Yoon-Hyun;Lee, Chung-Uk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.109.2-109.2
    • /
    • 2012
  • Current microlensing follow-up observations focus on high-magnification events because of the high efficiency of planet detection. However, central perturbations of high-magnification events caused by a planet can also be produced by a very close or a very wide binary companion, and the two kinds of central perturbations are not generally distinguished without time consuming detailed modeling (a planet-binary degeneracy). Hence, it is important to resolve the planet-binary degeneracy that occurs in high-magnification events. In this paper, we investigate caustic-crossing high-magnification events caused by a planet and a wide binary companion. From this study, we find that because of the different magnification excess patterns inside the central caustics induced by the planet and the binary companion, the light curves of the caustic-crossing planetary-lensing events exhibit a feature that is discriminated from those of the caustic-crossing binary-lensing events, and the feature can be used to immediately distinguish between the planetary and binary companions.

  • PDF

Hybrid-Domain High-Frequency Attention Network for Arbitrary Magnification Super-Resolution (임의배율 초해상도를 위한 하이브리드 도메인 고주파 집중 네트워크)

  • Yun, Jun-Seok;Lee, Sung-Jin;Yoo, Seok Bong;Han, Seunghwoi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1477-1485
    • /
    • 2021
  • Recently, super-resolution has been intensively studied only on upscaling models with integer magnification. However, the need to expand arbitrary magnification is emerging in representative application fields of actual super-resolution, such as object recognition and display image quality improvement. In this paper, we propose a model that can support arbitrary magnification by using the weights of the existing integer magnification model. This model converts super-resolution results into the DCT spectral domain to expand the space for arbitrary magnification. To reduce the loss of high-frequency information in the image caused by the expansion by the DCT spectral domain, we propose a high-frequency attention network for arbitrary magnification so that this model can properly restore high-frequency spectral information. To recover high-frequency information properly, the proposed network utilizes channel attention layers. This layer can learn correlations between RGB channels, and it can deepen the model through residual structures.

A Study on the Displacement Magnification Mechanism of Two-Lever System using Flexure Hinge (유연 힌지를 이용한 이중레버 시스템의 변위증폭 메카니즘에 관한 연구)

  • Jea, Wone-Soo;Ye, Sang-Don;Min, Byeong-Hyeon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.2
    • /
    • pp.60-65
    • /
    • 2008
  • The high-technology industries including a semi-conductor and an information communication need an ultra-precision technology from the technological points of view. Nano technology based on an ultra-precision technology is being studied to overcome the delicate technology that may occur in the semi-conductor fields. Then, the transferring equipment with high resolution and long displacement becomes an important technology. The goal of this study is to analyze the displacement magnification mechanism driven by piezoelectric actuator which has high resolution and fast response characteristics using flexure hinge with the merits of soft displacement, negligible back-lash and stick-slip, and no-lubrication. The analyses to reduce the magnification losses occurred during the magnification process are performed using ANSYS software based on FEM. The five design variables such as arm thickness, thickness of hinge, radius of hinge, length of input side at the 1st lever and magnification ratio of 1st lever are optimized to induce the maximum magnification ratio using Taguchi method.

  • PDF

Characterization of the Resonant Caustic Perturbation

  • Chung, Sun-Ju
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.48.1-48.1
    • /
    • 2010
  • Four of nine exoplanets found by microlensing were detected by the resonant caustic, which represents the merging of the planetary and central caustics at the position when the projected separation of a host star and a bounded planet is s~1. One of the resonant caustic lensing events, OGLE-2005-BLG-169, was a caustic-crossing high-magnification event with A_max ~800 and the source star was much smaller than the caustic, nevertheless the perturbation was not obviously apparent on the light curve of the event. In this paper, we investigate the perturbation pattern of the resonant caustic to understand why the perturbations induced by the caustic do not leave strong traces on the light curves of high-magnification events despite a small source/caustic size ratio. From this study, we find that the regions with small magnification excess around the center of the resonant caustic are rather widely formed, and the event passing the small-excess region produces a high-magnification event with a weak perturbation that is small relative to the amplification caused by the star and thus does not noticeably appear on the light curve of the event. We also find that the positive excess of the inside edge of the resonant caustic and the negative excess inside the caustic become stronger and wider as q increases, and thus the resonant caustic-crossing high-magnification events with the weak perturbation occur in the range of q $\leq$ 10-4. We determine the probability of the occurrence of events with the small excess $|\varepsilon|{\leq}3%$ in high-magnification events induced by a resonant caustic. As a result, we find that for the Earth-mass planets with a separation of ~2.5 AU the resonant caustic high-magnification events with the weak perturbation can occur with a significant frequen.

  • PDF

A Measurement Method of Three-Dimensional Surface Morphology Based on Depth-from-Focus through Linear Magnification Calibration (선형배율보정을 통한 DFF 기반의 삼차원 형상 측정법)

  • Kim, Gyung-Bum;Shin, Young-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.115-122
    • /
    • 2005
  • Errors resulting from magnification variations of a optical system are largely generated in three-dimensional shape measurements based on depth-from-focus. In the case of measuring the surface morphology of tiny objects based on DFF, images are acquired with a very small interval so that magnification changes can be minimized. However, the magnification variations are actually existed in the acquired images and so focus measures are wrongly or ambiguously extracted. In this paper, a methodology with linear magnification calibrations, based on DFF, is proposed to make more accurate measurement in surface morphology with high depth discontinuity, compared with previous ones. Several experiments show that the proposed method outperforms existing ones without magnification calibrations.

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • v.44 no.5
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.

A Measurement Method of Surface Morphology Based on Depth-from-Focus with Magnification Variations of Optical System (광학계의 배율 변화를 고려한 DFF 기반의 형상 측정법)

  • 신영수;김경범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1500-1503
    • /
    • 2004
  • Errors resulting from magnification variations of optical system are largely generated in three-dimensional shape measurements. In the case of measuring the surface morphology of tiny objects based on DFF, images are acquired with a very small interval and then magnification changes are minimized. However, the magnification variations are actually existed in optical system and so focus measures in DFF are wrongly or ambiguously extracted. in this paper, a methodology based on DFF with the magnification changes is proposed to make more accurate measurement in surface morphology with high depth discontinuity, compared with previous ones. Several experiments show that the proposed method outperforms existing ones without magnification changes.

  • PDF

A Study on Improvement of Image Magnification (확대된 영상의 향상에 관한 연구)

  • 양영수;강길봉;김무영;김장형
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.233-237
    • /
    • 2000
  • Generally, the still image magnification uses .image growing, interpolation in order to get magnificated image. Still image Magnification does not get high-resolution image because, amount of information is not sufficient. In this thesis, we proposed the enhance method of high resolution image magnification. Result of apply proposed method to Lena image, we gained result of enhancement more better than formerly simple technique.

  • PDF

Analysis of Multiple Displacement Magnification Mechanism in Ultraprecision Nano Stage (초정밀 나노 스테이지에서의 다중 변위 확대 기구 해석)

  • Min K.S.;Choi W.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1273-1276
    • /
    • 2005
  • A displacement magnification mechanism is usually employed in a nano-positioning stage to achieve a large stage motion. A lever mechanism is the most widely used displacement magnifying mechanism. For more large stage motion, double or multiple lever mechanisms can be used. In this case, a more accurate analysis model is needed. This study proposes a more reasonable analysis model for a multiple lever mechanism based on the single lever mechanism model. This paper describes that the high equivalent stiffness of the lever is the most important factor reducing the magnification ratio of the lever mechanism through increasing the deflection of the link and including the axial displacement of the pivot.

  • PDF

THE STUDY OF THE FOCAL TROUGH IN PANORAMIC RADIOGRAPH (파노라마방사선사진에 있어서 상층면적에 관한 연구)

  • Park Chang Seo;Kim Han Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-121
    • /
    • 1982
  • In the study of the focal trough of panoramic radiograph, using the Moritta compony Panex-EC a series of 48 exposures were: taken with the 6-18 brass pins placed in the holes of the plastic model plate, then eveluated by 4 observers. The author analyzed the focal trough defined by the sharpness criteria and calcuated the vertical and horizontal magnification range in the corrected focal trough. The results were as follows; 1. Continuous focal trough was not defined in the anterior region using a very high degree of sharpness. 2. As degree of sharpness used in the analysis became less, focal trough was continuous in the anterior and posterior regions, symmetrized bilaterally, and the widths of the focal trough increased more in the posterior region. e. As sharpness criteria were reduced, the percentage range of image magnification increased on both vertical and horizontal magnification, and especially the percentage range of horizontal magnification was greater than that of vertical magnification.

  • PDF