• Title/Summary/Keyword: high-end technology

Search Result 1,294, Processing Time 0.035 seconds

Construction of a artificial levee line in river zones using LiDAR Data (라이다 자료를 이용한 하천지역 인공 제방선 추출)

  • Choung, Yun-Jae;Park, Hyeon-Cheol;Jo, Myung-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.185-185
    • /
    • 2011
  • Mapping of artificial levee lines, one of major tasks in river zone mapping, is critical to prevention of river flood, protection of environments and eco systems in river zones. Thus, mapping of artificial levee lines is essential for management and development of river zones. Coastal mapping including river zone mapping has been historically carried out using surveying technologies. Photogrammetry, one of the surveying technologies, is recently used technology for national river zone mapping in Korea. Airborne laser scanning has been used in most advanced countries for coastal mapping due to its ability to penetrate shallow water and its high vertical accuracy. Due to these advantages, use of LiDAR data in coastal mapping is efficient for monitoring and predicting significant topographic change in river zones. This paper introduces a method for construction of a 3D artificial levee line using a set of LiDAR points that uses normal vectors. Multiple steps are involved in this method. First, a 2.5-dimensional Delaunay triangle mesh is generated based on three nearest-neighbor points in the LiDAR data. Second, a median filtering is applied to minimize noise. Third, edge selection algorithms are applied to extract break edges from a Delaunay triangle mesh using two normal vectors. In this research, two methods for edge selection algorithms using hypothesis testing are used to extract break edges. Fourth, intersection edges which are extracted using both methods at the same range are selected as the intersection edge group. Fifth, among intersection edge group, some linear feature edges which are not suitable to compose a levee line are removed as much as possible considering vertical distance, slope and connectivity of an edge. Sixth, with all line segments which are suitable to constitute a levee line, one river levee line segment is connected to another river levee line segment with the end points of both river levee line segments located nearest horizontally and vertically to each other. After linkage of all the river levee line segments, the initial river levee line is generated. Since the initial river levee line consists of the LiDAR points, the pattern of the initial river levee line is being zigzag along the river levee. Thus, for the last step, a algorithm for smoothing the initial river levee line is applied to fit the initial river levee line into the reference line, and the final 3D river levee line is constructed. After the algorithm is completed, the proposed algorithm is applied to construct the 3D river levee line in Zng-San levee nearby Ham-Ahn Bo in Nak-Dong river. Statistical results show that the constructed river levee line generated using a proposed method has high accuracy in comparison to the ground truth. This paper shows that use of LiDAR data for construction of the 3D river levee line for river zone mapping is useful and efficient; and, as a result, it can be replaced with ground surveying method for construction of the 3D river levee line.

  • PDF

The Evaluation of the Korean Advance Directives (K-AD) (한국형 사전의료의향서 평가)

  • Kim, KiSook;Kim, Shinmi;Hong, Sunwoo;Kim, JinShil
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.2
    • /
    • pp.109-118
    • /
    • 2016
  • The purpose of this study was to evaluate Korean advance directives (K-AD) by examining the degree of adults' acceptance and reliability of the directive itself. Methods: Survey was performed with 181 adults aged 20 or older who were recruited from three regions. A questionnaire used to examine the participants' acceptance of their K-AD in terms of visual analogue scale score of complexity, difficulty, necessity, satisfaction, recommendation. Then, a retest was carried out by asking participants to write up a K-AD again to confirm the reliability of the directives. Results: On a scale of 100, the average acceptance score was 70 or above, which represents rather high level of acceptance in all five categories. The test-retest reliability kappa values ranged from 0.592 to 0.950, and the conformity degree was moderate or high. Regarding K-AD components such as values, treatment preference, proxy appointment, differences among age groups were observed in each component. Conclusion: The results of this study suggest that K-AD is a feasible instrument to analyze its acceptability and reliability for adult population. K-AD could be utilized to help people make their own decision on their end-of-life care. Further studies are needed to confirm this study results and promote widespread use of K-AD.

Live Lines Tracing Method in Power Distribution System with 3-phase-4 wires (삼상 다중 접지 배전계통에서 활선로 추적 방법)

  • Zheng, Yan-peng;Byun, Hee-Jung;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.559-562
    • /
    • 2017
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace off-lines with high power impulse injection. Our proposed method use to trace live lines with very small power high frequency signal injection. Typical power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. Two end communication terminals are required to be synchronized between them for determination on electrically same phases. Challenging issue is to achieve synchronization without GPS providing synchronizing time. A novel power transformer and wire identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Encoder Type Semantic Segmentation Algorithm Using Multi-scale Learning Type for Road Surface Damage Recognition (도로 노면 파손 인식을 위한 Multi-scale 학습 방식의 암호화 형식 의미론적 분할 알고리즘)

  • Shim, Seungbo;Song, Young Eun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.2
    • /
    • pp.89-103
    • /
    • 2020
  • As we face an aging society, the demand for personal mobility for disabled and aged people is increasing. In fact, as of 2017, the number of electric wheelchair in the country continues to increase to 90,000. However, people with disabilities and seniors are more likely to have accidents while driving, because their judgment and coordination are inferior to normal people. One of the causes of the accident is the interference of personal vehicle steering control due to unbalanced road surface conditions. In this paper, we introduce a encoder type semantic segmentation algorithm that can recognize road conditions at high speed to prevent such accidents. To this end, more than 1,500 training data and 150 test data including road surface damage were newly secured. With the data, we proposed a deep neural network composed of encoder stages, unlike the Auto-encoding type consisting of encoder and decoder stages. Compared to the conventional method, this deep neural network has a 4.45% increase in mean accuracy, a 59.2% decrease in parameters, and an 11.9% increase in computation speed. It is expected that safe personal transportation will be come soon by utilizing such high speed algorithm.

Evaluation of N-RTK Positioning Accuracy for Moving Platform (기선 거리에 따른 이동체의 N-RTK 위치정확도 평가)

  • Kim, Min-Seo;Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2020
  • For real-time precise positioning, N-RTK (Network Real-Time Kinematic) technology is widely used these days. However, the currently operating N-RTK system has a limitation in terms of the number of users. Therefore, if reference points generate correction messages with no limit on the number of users are developed later, it is determined that an appropriate reference point installation interval is required, so that the accuracy of the N-RTK system according to the baseline distance was analyzed. This experiment utilized receivers with varying performance that estimated the rover position, and RTKLIB, an open-source software, is used for processing data. As a result, the rover position was estimated accurately with a high rate of fixed ambiguity for all the receivers. When the reference station with a baseline length of 40 km was used, the vertical RMSE (Root Mean Squared Error) was quite similar to the short baseline case, but only half of the ambiguity fixing rate was achieved. The outlier in the estimated rover position was not observed for the longer baselines in the case of a high-end receiver. It is necessary to analyze the ambiguity fixing and the accuracy of the kinematic positioning with scientific GNSS processing software.

Validation of Segmental Multi-Frequency Bioelectrical Impedance Analysis based on the Segmental Bioelectrical Impedance analysis in the Elderly Population (분절임피던스를 기준한 분절다주파수 생체임피던스의 일치도 분석)

  • Tang, Sae-Jo;Kim, Jang-Hee;Eom, Jin Jong;Eom, Sunho;Kim, Hakkyun;Kim, Chul-Hyun
    • Journal of Platform Technology
    • /
    • v.9 no.2
    • /
    • pp.38-45
    • /
    • 2021
  • A frequently used bioimpedance analytical method in Korea is the segmental multi-frequency BIA (SMF-BIA) method, but it is not directly determined at a segmented impedance. This study was to compare SMF-BIA determinations with direct segmented determinations for accuracy and appropriateness of segment parameters. This study is to compare the segment parameters, accuracy and appropriateness of the multi-frequency segmental bioimpedance analysis. To this end, 108 elderly individuals were measured. Segmented bioelectrical measurements obtained from a SMF-BIA (Inbody S10) at 50 kHz and measured with a phase sensitive single frequency device (SF-BIA, bia-101, RJL / akern systems) were compared. The significant difference (%) was demonstrated between single - and multiple frequency determinations of the right upper limb (R = 35.5 ± 6.2%, P < 0.001; Xc = 2.7 ± 7.6%, P < 0.01), left upper limb difference (R= 33. 9 ± 6.0%, P < 0.001; Xc = 2.8 ± 8.3%, P < 0.01), right lower limb difference (R = 18.6 ± 4.3%, P < 0.001; Xc = 25.8 ± 10.0%, P < 0.001), left lower limb difference (R = 18.0 ± 4.7%, P < 0.001; Xc = 31.8%). Of the results determined with the two BIA methods, the impedance measurements of the limbs and whole body showed a high correlation (RA: R = 0. 950, LA: R = 0. 949, RL: R = 0.899, LL: R = 0.88), and in the agreement test, the impedance values of the upper limbs and whole body also showed strong agreement (ICC > 0.9), but in the Xc, the correlation was weak. In conclusion, it was found that although bioimpedance devices had significantly different characteristics and inconsistent cross sectionally, there was a high population level agreement in the upper and lower extremities in determining segmental resistance value changes. But a large error was found on the trunk. Further studies were needed for reducing the error.

Implementation of a Personalized Restaurant Recommendation System for The Mobility Handicapped (교통약자를 위한 맞춤형 식당 추천시스템 구현)

  • Lee, Jin-Ju;Park, So-Yeon;Kim, Seo-Yun;Lee, Jeong-Eun;Kim, Keun-Wook
    • Journal of Digital Convergence
    • /
    • v.19 no.5
    • /
    • pp.187-196
    • /
    • 2021
  • The mobility handicapped are representative socially vulnerable people who account for a high percentage of our society. Due to the recent development of technology, personalized welfare technologies for the socially vulnerable are being studied, but it is relatively insufficient compared to the general people. In this study, we intend to implement a personalized restaurant recommendation system for the mobility handicapped. To this end, a hybrid recommendation system was implemented by combining the data of special transportation boarding and alighting history (7,153 cases) and information of Daegu Food restaurants (955 cases). In order to evaluate the effectiveness of the implemented recommendation system, we conducted performance comparisons with existing recommendation systems by prediction error rate and recommendation coverage. As a result of the analysis, the performance was higher than that of the existing recommendation system, and the possibility of a personalized restaurant recommendation system for the mobility handicapped was confirmed. In addition, we also confirmed the correlation in which similar restaurants are recommended in some types of the mobility handicapped. As a result of this study, it is judged that it will contribute to the use of restaurants with high satisfaction for the mobility handicapped, and the limitations of the study are also presented.

The Development of Education Method and Model for Convergence Reading Education in School Library (학교도서관 융합독서교육을 위한 교육방법 및 모형개발)

  • Cho, Soo-Youn;Cho, Miah
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.56 no.2
    • /
    • pp.5-33
    • /
    • 2022
  • In this study, the direction and contents of public education to develop competencies that are in line with the 2022 revised curriculum and the paradigm of future education were sought, and a plan for reading education was prepared. A creative and cooperative problem-solving method and process as not only information literacy ability to read, select, and reconstruct information but also transformative competency to respond to uncertain future and diversified situations are important amid the complex, pluralistic and rapid development of information and communication technology It was intended to give an experience of exploring and communicating through reading in order to explore and derive it. Analyze the general outline and syllabus of the curriculum, international education project definitions and indicators, and organize academic theories and research to set the direction and goal of high school reading education, and organize creative and convergence class strategies and reading activities A library reading class model was developed. Accordingly, the class model was revised by applying the development research method, and the final model was developed by supplementing it through field application evaluation. In order to achieve the research purpose end, a two-round Delphi survey was conducted on 10 reading education and curriculum experts. The model modified through the Delphi survey was developed in the final school library convergence reading class model by demonstrating the class in the educational field and supplementing it through application evaluation.

Acoustic images of the submarine fan system of the northern Kumano Basin obtained during the experimental dives of the Deep Sea AUV URASHIMA (심해 자율무인잠수정 우라시마의 잠항시험에서 취득된 북 구마노 분지 해저 선상지 시스템의 음향 영상)

  • Kasaya, Takafumi;Kanamatsu, Toshiya;Sawa, Takao;Kinosita, Masataka;Tukioka, Satoshi;Yamamoto, Fujio
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.80-87
    • /
    • 2011
  • Autonomous underwater vehicles (AUVs) present the important advantage of being able to approach the seafloor more closely than surface vessel surveys can. To collect bathymetric data, bottom material information, and sub-surface images, multibeam echosounder, sidescan sonar (SSS) and subbottom profiler (SBP) equipment mounted on an AUV are powerful tools. The 3000m class AUV URASHIMA was developed by the Japan Agency for Marine-Earth Science and Technology (JAMSTEC). After finishing the engineering development and examination phase of a fuel-cell system used for the vehicle's power supply system, a renovated lithium-ion battery power system was installed in URASHIMA. The AUV was redeployed from its prior engineering tasks to scientific use. Various scientific instruments were loaded on the vehicle, and experimental dives for science-oriented missions conducted from 2006. During the experimental cruise of 2007, high-resolution acoustic images were obtained by SSS and SBP on the URASHIMA around the northern Kumano Basin off Japan's Kii Peninsula. The map of backscatter intensity data revealed many debris objects, and SBP images revealed the subsurface structure around the north-eastern end of our study area. These features suggest a structure related to the formation of the latest submarine fan. However, a strong reflection layer exists below ~20 ms below the seafloor in the south-western area, which we interpret as a denudation feature, now covered with younger surface sediments. We continue to improve the vehicle's performance, and expect that many fruitful results will be obtained using URASHIMA.

A Study on the Applicability of Soilremediation Technology for Contaminated Sediment in Agro-livestock Reservoir (농축산저수지 오염퇴적토의 토양정화기술에 대한 적용성 연구)

  • Jung, Jaeyun;Chang, Yoonyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.3
    • /
    • pp.157-181
    • /
    • 2020
  • Sediments from rivers, lakes and marine ports serve as end points for pollutants discharged into the water, and at the same time serve as sources of pollutants that are continuously released into the water. Until now, the contaminated sediments have been landfilled or dumped at sea. Landfilling, however, was expensive and dumping at sea was completely banned due to the London Convention. Therefore, this study applied contaminated sedimentation soil of 'Royal Palace Livestock Complex' as soil purification method. Soil remediation methods were applied to pretreatment, composting, soil washing, electrokinetics, and thermal desorption by selecting overseas application cases and domestically applicable application technologies. As a result of surveying the site for pollutant characteristics, Disolved Oxigen (DO), Suspended Solid (SS), Chemical Oxygen Demand (COD), Total Nitrogen (TN), and Total Phosphorus (TP) exceeded the discharged water quality standard, and especially SS, COD, TN, and TP exceeded the standard several tens to several hundred times. Soil showed high concentrations of copper and zinc, which promote the growth of pig feed, and cadmium exceeded 1 standard of Soil Environment Conservation Act. In the pretreatment technology, hydrocyclone was used for particle size separation, and the fine soil was separated by more than 80%. Composting was performed on organic and Total Petroleum Hydrocarbon (TPH) contaminated soils. TPH was treated within the standard of concern, and E. coli was analyzed to be high in organic matter, and the fertilizer specification was satisfied by applying the optimum composting conditions at 70℃, but the organic matter content was lower than the fertilizer specification. As a result of continuous washing test, Cd has 5 levels of residual material in fine soil. Cu and Zn were mostly composed of ion exchange properties (stage 1), carbonates (stage 2), and iron / manganese oxides (stage 3), which facilitate easy separation of contamination. As a result of applying acid dissolution and multi-stage washing step by step, hydrochloric acid, 1.0M, 1: 3, 200rpm, 60min was analyzed as the optimal washing factor. Most of the contaminated sediments were found to satisfy the Soil Environmental Conservation Act's standards. Therefore, as a result of the applicability test of this study, soil with high heavy metal contamination was used as aggregate by applying soil cleaning after pre-treatment. It was possible to verify that it was efficient to use organic and oil-contaminated soil as compost Maturity after exterminating contaminants and E. coli by applying composting.