• Title/Summary/Keyword: high-density polyethylene (HDPE)

Search Result 177, Processing Time 0.028 seconds

Manufacture of Short Fiber Prepreg using Electroflocking (Electroflocking을 이용한 단섬유 프리프레그 제조에 관한 연구)

  • Lim, S.H.;Lee, S.S.;Pak, M.;Kim, J.K.;Choe, C.R.;Kwon, S.J.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.288-291
    • /
    • 2002
  • The carbon fiber or glass fiber reinforced prepregs were manufactured using electrostatic flocking technology. The powder of high density polyethylene was used as a matrix. The base film of polyethylene was prepared using a fluidized bed of polyethylene powder under the high electric field. We obtained HDPE film with uniform thickness of minimum $80\mu\textrm{m}$. And the fibers were aligned on the molten HDPE film by the electroflocking process. The short fibers with 1mm were easily electrically charged and aligned under the high electric field. The carbon fibers with high conductivity were elasily electrically charged than the glass fibers with low conductivity. So lower electric field was needed for the carbon fibers.

  • PDF

Properties of the Blends of HDPE and EPDM Cured under Shear by Roll Mill (Roll Mill에서 가교된 EPDM과 HDPE 블렌드의 물성에 관한 연구)

  • Ha, Chang-Sik;Cho, Won-Jei
    • Elastomers and Composites
    • /
    • v.26 no.1
    • /
    • pp.15-22
    • /
    • 1991
  • Blends of ethylene-propylene-diene terpolymer(EPDM) and high density polyethylene(HDPE) have been prepared in a roll mill by the process "dynamic curing" where both blending and a crosslinking reaction was carried out simultaneously. As a crosslinking agent, dicumyl peroxide(DCP) was used. Throughout the experimental ranges, the dynamically cured polyblends were shown to be thermoplastic elastomers except highly crosslinked blends of high compositions of EPDM. The increase of melt viscosity was observed as EPDM composition and DCP contents increased. From DSC determinations, the crystallinity decreased with increasing contents of DCP. The tensile strength and elongation at break generally increased with increasing DCP content and increasing HDPE compositions, but highly depended on the combined effects of decreasing crystallinity and increasing crosslinking density.

  • PDF

Development of a Short-term Failure Assessment of High Density Polyethylene Pipe Welds - Application of the Limit Load Analysis - (고밀도 폴리에틸렌 융착부에 대한 단기간 파손 평가법 개발 - 한계하중 적용 -)

  • Ryu, Ho-Wan;Han, Jae-Jun;Kim, Yun-Jae;Kim, Jong-Sung;Kim, Jeong-Hyeon;Jang, Chang-Heui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.405-413
    • /
    • 2015
  • In the US, the number of cases of subterranean water contamination from tritium leaking through a damaged buried nuclear power plant pipe continues to increase, and the degradation of the buried metal piping is emerging as a major issue. A pipe blocked from corrosion and/or degradation can lead to loss of cooling capacity in safety-related piping resulting in critical issues related to the safety and integrity of nuclear power plant operation. The ASME Boiler and Pressure Vessel Codes Committee (BPVC) has recently approved Code Case N-755 that describes the requirements for the use of polyethylene (PE) pipe for the construction of Section III, Division 1 Class 3 buried piping systems for service water applications in nuclear power plants. This paper contains tensile and slow crack growth (SCG) test results for high-density polyethylene (HDPE) pipe welds under the environmental conditions of a nuclear power plant. Based on these tests, the fracture surface of the PENT specimen was analyzed, and the fracture mechanisms of each fracture area were determined. Finally, by using 3D finite element analysis, limit loads of HDPE related to premature failure were verified.

FTIR study of gamma and electron irradiated high-density polyethylene for high dose measurements

  • Al-Ghamdi, Hanan;Farah, Khaled;Almuqrin, Aljawharah;Hosni, Faouzi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.255-261
    • /
    • 2022
  • A reliable and well-characterized dosimetry system which is traceable to the international measurement system, is the key element to quality assurance in radiation processing with cobalt-60 gamma rays, X-rays, and electron beam. This is specifically the case for health-regulated processes, such as the radiation sterilization of single use medical devices and food irradiation for preservation and disinfestation. Polyethylene is considered to possess a lot of interesting dosimetric characteristics. In this work, a detailed study has been performed to determine the dosimetric characteristics of a commercialized high-density polyethylene (HDPE) film using Fourier transformed infrared spectrometry (FTIR). Correlations have been established between the absorbed dose and radiation induced infrared absorption in polyethylene having a maximum at 965 cm-1 (transvinylene band) and 1716 cm-1 (ketone-carbonyl band). We have found that polyethylene dose-response is linear with dose for both bands up to1000 kGy. For transvinylene band, the dose-response is more sensitive if irradiations are made in helium. While, for ketone-carbonyl band, the dose-response is more sensitive when irradiations are carried out in air. The dose-rate effect has been found to be negligible when polyethylene samples are irradiated with electron beam high dose rates. The irradiated polyethylene is relatively stable for several weeks after irradiation.

Explosion Characteristics Analysis of Low-Density Polyethylene Dust (저밀도 폴리에틸렌 분진의 폭발특성 분석)

  • Hyun-gil Kwon;Kyeong-seok Oh;Jong-bae Baek;Dong-hyun Seo
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.80-88
    • /
    • 2023
  • Ensuring safety in the designing of manufacturing and handling facilities for low-density polyethylene (LDPE) is difficult because there are no standards for the dust explosion characteristics of LDPE. In this study, a dust explosion test was performed on two dust samples collected from a bag filter (LDPE 1) during the LDPE manufacturing process and sedimentary dust (LDPE 2) leaked outside a facility such as a silo, and the LDPE 2 explosion test results were summarized. Particle size analysis showed that the volume-based particle diameter (median) was 95.04 ㎛ and the number density was 0-1 ㎛. The maximum explosion pressure (Pmax) was 6.6 bar, and the maximum rate of explosion pressure rise was 366 [bar/s] at 1500 g/m3. Accordingly, the dust explosion index (Kst) was 99.4 bar·m/s, which was confirmed as ST-1 grade. Moreover, the minimum ignition energy and minimum ignition temperature was 10 mJ and 450 ℃, respectively. Currently, manufacturing and handling design is based on the characteristic values of high-density polyethylene (HDPE). However, as the test results show that LDPE 2 dust has a higher risk than HDPE (particle diameter 61.6 ㎛), caution is required when using the HDPE design criteria in the LDPE manufacturing process.

Effects of a Radiation Crosslinking on a Drawn Microporous HDPE Film with a Nucleating Agent

  • Park, Jong-Seok;Gwon, Sung-Jin;Lim, Youn-Mook;Nho, Young-Chang
    • Macromolecular Research
    • /
    • v.17 no.8
    • /
    • pp.580-584
    • /
    • 2009
  • The effects of crystallinity and radiation crosslinking on the physical properties of a microporous high density polyethylene (HDPE) film with Millad3988 as a nucleating agent were investigated. The pores of the HDPE film were affected by the crystallinity. The crystallinity of the HDPE films increased with increasing Millad3988 amount up to 0.1 wt% but decreased with further addition. The mechanical characteristics of the HDPE containing Millad3988 films improved with increasing irradiation dose up to 50 kGy, but decreased at 75 kGy due to severe degradation. The thermal shrinkage behavior of the HDPE films decreased with increasing radiation dose up to 50 kGy. The porosity of the stretched HDPEIMillad3988 films after ${\gamma}$-ray radiation increased with increasing y-ray radiation dose up to 50 kGy. The pores of the irradiated films were formed more easily by a stretching due to the formation of a crosslinked structure.

Design of Dual Curved Lens for Millimeter-Wave Imaging (밀리미터파 이미징을 위한 이중 곡률 렌즈의 설계)

  • Lee, Won-Hui;Pyo, Seongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.239-242
    • /
    • 2016
  • In this paper, we proposed the dual curved lens of concave type. HDPE (High Density Polyethylene) used to fabricate the dual curved lens. The dual curved lens consisted of two concave structures. Role of two concave structures is to beam uniform and expansion. A small concave structure has the greater curvature than big concave structure. The dual curved lens will apply to millimeter imaging system. We measured the dual curved lens performance using 250 GHz VDI source. And we simulated the dual curved lens using ZEMAX. Fabricated lens have a good performance for beam uniform and expansion.

Mechanical and Thermal Properties of Liquefied Wood Polymer Composites (LWPC)

  • Hyun, Doh Geum;Kang, In Aeh;Lee, Sun Young;Kong, Young To
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.67-73
    • /
    • 2004
  • The influence of liquefied wood (LW) on the mechanical and thermal properties of liquefied wood-polymer composites (LWPC) was investigated in this study. The thermal behaviors of LWPC were characterized by means of thermogravimetric (TGA) and differential scanning calorimetric (DSC) analyses. LW showed significant effects on the mechanical strength properties. The increase of flexural MOE and Young's modulus was related to the increase of stiffness of LWPC. The effect of LW was also significant on the flexural and tensile MOR. The impact strength decreased with the increase of LW application level. With the increased stress concentration by the poor bonding between LW and polymer, the impact strength of LWPC decreased, compared with that of high-density polyethylene (HDPE). The thermal stability of LWPC decreased with the increase of LW content up to 40%. The melting temperature of HDPE decreased with the increase of LW loading level. Enthalpy of HDPE also decreased with the addition of LW. This study proves the thermal stability necessary for the consolidation of composition materials.

Effect of Ozone Treatment of Carbon Nanotube on PTC/NTC Behaviors of High-Density Polyethylene Matrix Composites (오존처리에 따른 탄소나노튜브 강화 고밀도 폴리에틸렌 기지 복합재료의 PTC/NTC 특성)

  • Park, Soo-Jin;Seok, Su-Ja;Lee, Jae-Rock;Hong, Sung-Kwon
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.32-35
    • /
    • 2005
  • In this paper, the carbon nanotubes (CNTs) were ozonized and the positive temperature coefficient (PTC) behaviors of CNTs-filled high-density polyethylene (HDPE) conductive composites were studied. The results of element analysis (EA) and FT-IR indicate that the oxygen-containing functional groups on the CNTs surfaces, such as O-H, C-O, and C=O groups, were increased with the ozonization. Electrical resistivities of the CNTs/HDPE composites were measured by using a digital multimeter. The resistivity of the composites was increased abruptly near the crystalline melting temperature of the HDPE used as matrix, which could be attributed to the destruction of conductive network by the thermal expansion of HDPE. And, the PTC intensity of the CNTs/HDPE composites was increased with the increase of the ozone treatment time. It was probably due to the growing of maximum volume resistivity of the composites induced by the increased oxygen-containing functional groups in the CNTs surfaces.

Material Development of Eco Water Tank with High Density Polyethylene and Low-temperature Concrete (친환경 저수조를 위한 고밀도 폴리에틸렌과 저열성 콘크리트 합성재료 개발)

  • Chang, Chun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.133-140
    • /
    • 2010
  • The purpose of this study is to evaluate the new eco water tank which is made of high density polyethylene and concrete with low temperature cement. The strength and failure mode of eco water tank was examined through tensile test with mixture of concrete and HDPE, temperature monitoring for various kind of concrete, admixture contains etc. The strength and failure mode were examined through tensile test with mixture of concrete and HDPE, temperature monitering for different kinds of concrete, strength test with different admixtures etc. It was found that shear connector between concrete and HDPE effects significantly contributed to the combined structures. ㄱ type shear connector results in tensile strength of up to 40% compared to that of V type shear connector. Based on test result, the new eco composite tank improved the stability and safety the old one and demonstrated the applicability and capability.