• Title/Summary/Keyword: high voltage discharge plasma

Search Result 223, Processing Time 0.023 seconds

NOx removal characteristics by the dielectric packed-bed plasma reactor (Dielectric packed-bed 플라즈마 반응기를 사용한 NOx 제거 특성)

  • Kim, Eung-Bok;Kim, Dong-Ook;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1087-1089
    • /
    • 1999
  • This paper presents the removal characteristics of nitrogen oxides (NOx) by the dielectric ($Al_{2}O_{3}$) packed-bed plasma reactor. Reactor packed with 5-mm diameter $Al_{2}O_{3}$ beads, and was designed to remove NOx at atmospheric pressures from the moving pollution source such as diesel automobile. The experiments were conducted for applied voltages from 5 to 10kV, flue gas rate from 2 to 5L/min, and frequency from 0.5 to 2kHz. The NOx removal efficiency significantly increased with increasing applied voltage. Especially removal rate significantly increased with increasing frequency. However, in this experiment discharge power was relatively high.

  • PDF

Effect of Working Gas Pressure on Misfirng of ac PDP at High Ambient Temperature

  • Ryu, Jae-Hwa;Choi, Joon-Young;Kim, Dong-Hyun;Kim, Joong-Kyun;Kim, Young-Kee;Lee, Ho-Jun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.4 no.4
    • /
    • pp.25-32
    • /
    • 2003
  • One of the important problems in ac PDP in recent years is the misfiring of ac PDP at high ambient temperatures which consequently degrades the image quality of the ac PDP. This may be due to the change of working gas pressure and/or MgO surface characteristics at high ambient temperatures. This paper deals with the effect of working gas pressure on the misfiring of ac PDP at high ambient temperature. From this study, we found that the main cause of the misfiring at high ambient temperature is the increase in discharge firing voltage induced by increased working gas pressure

OPP Polymer의 Plasma 표면 처리에 따른 Al 접착력의 향상

  • 한세진;김용한;이택동
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.212-212
    • /
    • 1999
  • Ar-O2 분위기의 Plasma 표면 처리된 OPP 의 polymer 위에 약 400$\AA$ 정도로 sputter 코팅된 Al의 부착력에 관하여 연구를 하였다. 금속과 polymer와 같이 성질이 서로 다른 물질이 서로 결합할 때 접착력은 제품의 성능과 신뢰도를 결정하는데 매우 중요한 인자이다. 최근 고분자재료의 표면을 플라즈마 처리 (plasma surface treatment)에 의해 고분자와 금속도포(coating) 층간의 접착력향상에 따라, 증착필름 및 인쇄용 필름 등의 기능도 향상시킬 수 있다. 저온 plasma를 이용한 표면처리는 plastic 재료가 가지고 있는 기본적인 특성을 저해하지 않고, 그 표면 층만을 개량하는 plasma 또는 sputter etching 갚은 electrical discharge 방법은 진공 증착 방식에서 많이 사용되고 있다. 7$\mu\textrm{m}$의 두께 OPP polymer를 10m/min의 속도로 OPP의 표면을 연속 plasma pretreatment를 하였다. 5$\times$10-2torr에서, PEM(Plasma Emission Monitor)를 이용하여 plasma intensity에 따른 Ar/O2비를 변화시키면서 test를 하였다. AFM과 XPS를 이용하여 OPP의 표면분석을 하였다. 이 plasma처리는 기존의 D.C plasma 처리 방식과는 달리 Midium frequency AC voltage hollow cathod 방식으로 plasma를 발생된 high energy plasma 분위기를 만들 수 있다. 이러한 방식은 -cycle일 때 plasma로부터 발생된 전자가 polymer 표면을 bombard 하게 되고, +cycle 일 때 polymer 표면이 cathod 가 되어 active ion에 의해 sputtering 이 된다. 이때 plasma 처리기의 polymer 기판 후면에 magnet를 설치하여 높은 ionization을 발생시켜 처리 효과를 한층 높여 주었다. 이 plasma 처리는 표면 청정화, 표면 etching 이 동시에 행하는 것과 함께 장시간 처리에 의해 표면에서는 미세한 과, C=C기, -C-O-의 극성기의 도입에 의한 표면 개량이 된다는 것을 관찰할 수 있다. OPP polymer 표면을 Ar 100%로 plasma 처리한 경우 C-O, C=O 등의 carbonyl가 발생됨을 알 수 있었다. C-O, C=O 등의 carbynyl polor group이 도입됨에 따라 sputter된 Al의 접착력이 향상됨을 알 수 있으며, TEM 관찰 결과 grain size도 상당히 작아짐을 알 수 있었다.

  • PDF

Removal Characteristics of Nitrogen Oxide in Electromagnetic-Catalytic Plasma Reactor (전자계-촉매형 플라즈마 반응기의 질소 산화물 제거 특성)

  • 이현수;박재윤;이동훈;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.7
    • /
    • pp.640-648
    • /
    • 2002
  • This study is to develop electromagnetic-catalyst application plasma reactors for indoor air purification. Nitrogen Oxide(NOx) removal characteristics are measured in the electromagnetic catalyst application plasma reactors with various parameters and the effect of catalyst or/and magnetic field are investigated on the NOx removal. And AC or DC high voltage is applied for corona discharge, flow rates are 150~1500 $\ell/min$ and NO initial concentration is about 10 ppm. $Mn0_2$ and $TiO_2$ catalysts to increase NOx removal rate are used. In the results, NOx removal rate by AC power is about 10 % higher than that by DC power under the experimental condition of 700 $\ell/min$, 5 magnets, $MnO_2$ and $Ti)_2$ catalysts. When magnet is applied to the reactor, NOx removal rate increased. Also, the reactor with $MnO_2$ and $Ti)_2$ catalyst and magnet have the best removal rate.

Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge (고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구)

  • Chung, Kyoung-Jae;Lee, Seok-Geun;Dang, Jeong-Jeung;Choi, Gil-Hwan;Hwang, Y.S.;Kim, Chul-Young;Park, Young-Jun
    • The Journal of Engineering Geology
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The application of appropriate rehabilitation methods can improve the efficiency of clogged wells and extend their life. In this paper, we study the feasibility of well cleaning using high-voltage pulsed discharge, in which electrical energy is used to produce impulsive pressure in water, in contrast to conventional methods that employ chemical or pneumatic energy sources. This technique utilizes the compressive shock wave generated by the expansive force of hot, dense plasma that is produced during a pulsed discharge in the gap between electrodes immersed in water. Compared with conventional techniques, this method is simple, and easy to handle and control. Using a capacitive pulsed power system with an electrical energy of 200 J, an impulsive pressure of 10.7 MPa is achieved at the position 6 cm away from the discharge gap. The amplitude of the impulsive pressure was easily controlled by adjusting the charging voltage of the capacitor and was almost linearly proportional to peak discharge current. The technique achieved good results in cleaning feasibility tests with mock-up specimens similar to clogged well screens.

Fabrication and Its Characteristics of Ion Energy Spectrometer for Diagnostics of Plasma (플라즈마 진단을 위한 이온에너지 분석장치의 제작 및 특성 조사)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.163-170
    • /
    • 1998
  • An ion energy spectrometer which has the $45^{\circ}$ parallel electrostatic deflection plate was designed and constructed for measuring ion temperature in high temperature plasma. The energy calibration and the energy resolution were studied in detail for a hydrogen ion at the $0.24{\sim}1.92\;keV$ energy using electrostatic accelerator with a duoplasmatron ion source. The voltage of the deflection plate was linearly increased for the decreased ion detector position at the constant ion energy and decreased for the increased ion energy at the fixed ion detector position. The inclination of the deflection plate voltage to the ion energy was between 0.92 and 1.61, and linearly decreased for the increased the ion detector position. The measured energy resolution, which is $4.2%\;{\sim}\;11.6%$ in this experiment region, was improved for the increased ion dector position and ion energy. The relative efficiency was increased for the decreased the ion detector position. The ion energy spectrum of the DC plasma in the multi-purpose plasma generator was measured using this equipment. The ion temperature was 203-205 eV at the discharge voltage 320 V, discharge current 1.7 A.

  • PDF

Depolymerization of Fucoidan by Contact Glow Discharge Electrolysis(CGDE) (접촉 글로우 방전 전기분해(CGDE)에 의한 후코이단의 저분자화)

  • Bae, Jung Shik;Lee, Jung Shik;Kim, Young Suk;Sim, Woo Jong;Lee, Ho;Chun, Ji Yeon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.886-891
    • /
    • 2008
  • Contact glow discharge electrolysis(CGDE) is an unconventional electrolysis where plasma is sustained by D.C. glow discharge between an electrode and the surface of electrolyte surrounding it at high voltage. In this study, the behavior of CGDE in NaCl solution and the depolymerization of fucoidan by CGDE were investigated. After onset of CGDE, increase of voltage enhanced Glow discharge which resulted in low current density and low temperature in NaCl electrolyte. From the variation of molecular weight of fucoidan with the reaction time, it was demonstrated that the degradation of fucoidan followed a first-order rate law. Molecular weight of fucoidan treated with CGDE was about 40 times lower compared to initial fucoidan without content decrease of sulfate and fucos.

Optimization of Gas Mixing-circulation Plasma Process using Design of Experiments (실험계획법을 이용한 가스 혼합-순환식 플라즈마 공정의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.359-368
    • /
    • 2014
  • The aim of our research was to apply experimental design methodology in the optimization of N, N-Dimethyl-4-nitrosoaniline (RNO, which is indictor of OH radical formation) degradation using gas mixing-circulation plasma process. The reaction was mathematically described as a function of four independent variables [voltage ($X_1$), gas flow rate ($X_2$), liquid flow rate ($X_3$) and time ($X_4$)] being modeled by the use of the central composite design (CCD). RNO removal efficiency was evaluated using a second-order polynomial multiple regression model. Analysis of variance (ANOVA) showed a high coefficient of determination ($R^2$) value of 0.9111, thus ensuring a satisfactory adjustment of the second-order polynomial multiple regression model with the experimental data. The application of response surface methodology (RSM) yielded the following regression equation, which is an empirical relationship between the RNO removal efficiency and independent variables in a coded unit: RNO removal efficiency (%) = $77.71+10.04X_1+10.72X_2+1.78X_3+17.66X_4+5.91X_1X_2+3.64X_2X_3-8.72X_2X_4-7.80X{_1}^2-6.49X{_2}^2-5.67X{_4}^2$. Maximum RNO removal efficiency was predicted and experimentally validated. The optimum voltage, air flow rate, liquid flow rate and time were obtained for the highest desirability at 117.99 V, 4.88 L/min, 6.27 L/min and 24.65 min, respectively. Under optimal value of process parameters, high removal(> 97 %) was obtained for RNO.

Effect of Hydrophobizing Method on Corrosion Resistance of Magnesium Alloy with Plasma Electrolytic Oxidation (소수성 처리 방법에 따른 플라즈마 전해 산화 처리된 마그네슘 합금의 내식성)

  • Joo, Jaehoon;Kim, Donghyun;Jeong, Chanyoung;Lee, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.2
    • /
    • pp.96-102
    • /
    • 2019
  • Magnesium and its alloys are prone to be corroded, thus surface treatments improving corrosion resistance are always required for practical applications. As a surface treatment of magnesium alloys, plasma electrolytic oxidation (PEO), creating porous stable oxide layer by a high voltage discharge in electrolyte, enhances the corrosion resistance. However, due to superhydrophilicity of the porous oxide layer, which easily allow the penetration of corrosive media toward magnesium alloys substrate, post-treatments inhibiting the transfer of corrosive media in porous oxide layer are required. In this work, we employed a hydrophobizing method to enhance the corrosion resistance of PEO treated Mg alloy. Three types of hydrophobizing techniques were used for PEO layer. Thin Teflon coating with solvent evaporation, self-assembled monolayer (SAM) coating of octadecyltrichlorosilane (OTS) based on solution method and SAM coating of perfluorodecyltrichlorosilane (FDTS) based on vacuum method significantly enhances corrosion resistance of PEO treated Mg alloy with reducing the contact of water on the surface. In particular, the vacuum based FDTS coating on PEO layer shows the most effective hydrophobicity with the highest corrosion resistance.

Preparation and Characterization of β-C3N4 in Presence of Seed Carbon Nitride Films Deposited by Laser-Electric Discharge Method

  • Kim, J.I.;Zorov, N.B.;Burdina, K.P
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.29-33
    • /
    • 2002
  • A procedure was developed for preparing bulk carbon nitride crystals from a polymeric $\alpha$ -C$_3$N$\_$4.2/ at high pressure and temperature in the presence of seeds of crystalline carbon nitride films prepared by a high voltage discharge plasma combined with pulsed laser ablation of graphite target. The samples were evaluated by x-ray photoelectron spectroscopy (XPS), infrared (IR) spectroscopy, Auger electron spectroscopy (AES), secondary-ion mass spectrometry (SIMS), scanning electron microscopy (SEM) and x-ray diffraction (XRD). Notably, XPS studies of the film composition before and after thermobaric treatments demonstrate that the nitrogen composition in $\alpha$ -C$_3$N$\_$4.2/ material initially containing more than 58% nitrogen decreases during the annealing process and reaches a common, stable composition of ~45%. The thermobaric experiments were performed at 10-77 kbar and 350-1200 $\^{C}$.