• 제목/요약/키워드: high voltage cable

검색결과 339건 처리시간 0.022초

맨홀용 및 핸드홀용 지중 저압케이블 접속장치 개발 (Development of connection device for underground low voltage cable of manhole and handhole)

  • 이강중;이은정;주종민;유근양
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1056-1058
    • /
    • 2005
  • It shows a tendency to increase rapidly underground of the city due to the build up of the large residential districts with industrial development, so there is required the development of the connection device for underground low voltage cable with high quality & convenient for use with consideration for installation condition of the underground. Hence, We will have the development of the connection device for underground low voltage cable, which is made waterproof perfectly under the flood of the underground for the long time, is convenient for use in spite of narrow area such as manhole or handhole, and can be able to prevent the release by the vibration.

  • PDF

PD Diagnosis on 22.9kV XLPE Underground Cable using Ultra-wideband Sensor

  • Lwin, Kyaw-Soe;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.422-429
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band (UWB) sensor design and study of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with the newly designed UWB sensor. In this study, we designed a new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both the low frequency and high frequency band of the partial discharge signal. Experiments of offline PD testing on medium voltage (22.9kV) underground cable mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative tests, the calibration signal injection test provided with the conventional IEC 60270 method and high voltage injection testing are included.

초고압 지중 OF 케이블 접속재의 전계해석에 관한 연구 (A Study on the Electric Field Analysis of Extra-High Voltage Oil-Filled Cable Accessories)

  • 이종범;강동식;강도현;이수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.432-435
    • /
    • 1989
  • This paper presents an algorithm for electric field analysis which is essential to insulation design of extra-high voltage oil-filled cable accessories using finite element method. Governing equation is induced by electromagnetic equation. Variational method is adopted for FEN formulation. Automatic mesh generation which saves time and labor is introduced for the input data. The application results of proposed algorithms were used for insulation design to develop 345kV cable joint.

  • PDF

초전도기기를 적용한 미래 저압대용량 신 배전계통 (Future New Distribution System with Low voltage and Mass Capacity using HTS equipments)

  • 윤재영;김종율;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권1호
    • /
    • pp.37-41
    • /
    • 2005
  • This paper describes the construction scheme of new distribution system using HTS(High Temperature Superconducting) power equipments such as cable, transformer and FCL(fault current limiter). At present, one of the most serious problems in distribution power system, especially for metropolitan complex city, is to obtain the ROW for cable line routes, space for downtown substations and satisfy the environmental protection caused by NIMBY phenomena. Unfortunately, it is expected that this situation will get more and more worse. As the HTS technology to apply in power system Is developed, HTS cable utilizing mass-capacity characteristic can be a useful countermeasure to overcome this problem. This paper describes the application methodology of 22.9kV HTS cable with low-voltage, mass-capacity characteristics replacing the 154kV conventional cable. By applying 22.9kV HTS cable, the HTS transformer with higher capacity for the reduction of space and transformer numbers of downtown substation is necessary. Also, if the leakage Impedance of HTS transformer is same as or lower than that of conventional transformer, the fault current of 22.9kV bus will increase because the HTS transformer capacity is larger than that of the conventional transformer. This means the parallel application of HTS-FCL to reduce the fault current in addition to the HTS cable and transformer can be necessary. With the basic construction scheme of new distribution system, this paper describes the future study points to realize this new distribution system using HTS equipments.

고온초전도 케이블의 대도시 계통 적용을 위한 송전용량과 전압계급의 검토 (A Study on Capacity and Voltage Class to supply HTS Power Transmission Cable to Metropolitan Area)

  • 최상봉;김대경;정성환;성기철;김학만;김태현;김종율
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.211-214
    • /
    • 2002
  • It becomes difficult and high in cost to construct new ducts and/or tunnels for power cable in Metropolitan area. This paper presents the possible application of a HTS superconducting power cable for transmitting electric power in metropolitan areas, reflecting its important distinction such as compactness for installation in underground ducts and considerably economical efficiency comparable to present underground cables. In this paper, review of transmission capacity and voltage class of compact HTS cable which should be applied to existing ducts was performed.

  • PDF

Land and Sea Cable Interconnections with HVDC Light

  • Gunnar, Asplund;Kjell, Eriksson;Ove, Tollerz
    • 전력전자학회지
    • /
    • 제6권4호
    • /
    • pp.21-26
    • /
    • 2001
  • HVDC Light는 300MW에 이르는 전력을 가지고 있는 아불 성형된 DC Cable과 Voltage Source 컨버터에 기반을 둔 가장 최근의 HVDC 기술이다. HVDC Light 컨버터는 IGBT(Insulated Gate bi-polar Transistor)와 유효전력과 무효전력 사이의 고속 컨트롤을 위한 PWM(펄스 폭 변조)의 기능을 가지고 있다. HVDC Light 케이블은 압출 성형된 폴리머의 절연을 가진 케이블이며 직류 전압을 위해 특별히 개조되었다. 전력 범위 내에서 HVDC Light 컨버터와 케이블은 지중 또는 해저 송전 등에서도 송전전력을 위해 훌륭하게 조합될 수 있었다. 본 원고는 실제의 케이스로부터 얻은 경험지식으로, HVDC Light 기술의 조합을 사용해 해결된 문제점을 소개하고, HVDC Light의 장점을 설명하였다.

  • PDF

Analysis on the Switching Surge Characteristics of a High-Voltage Induction Motor Fed by PWM Inverter Using EMTP

  • Kim Jae-Chul;Song Seung-Yeop;Lee Do-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.22-30
    • /
    • 2005
  • The PWM inverter drive may cause an over voltage at the motor terminal, which imposes severe electric stresses on the inter-turn insulation of motor windings. Unlike low-voltage induction motors, high-voltage induction motors have a stator type of form-wound coil for insulation and are insulated to the slot and the coil. So, this paper presents a PWM 3-level inverter, H-Bridge cascaded 7-level inverter and High-voltage induction motor model. It then analyzes the voltage that generates at the input terminal of the high-voltage induction motor fed by each inverter. Also, in order to examine a factor that influences the switching surge voltage, this paper proposes the system equivalent model and performs the case studies using EMTP.

멀티레벨 인버터 구동 고압유도전동기에시 발생하는 과도과전압 저감을 위한 LCR필터의 효과분석 (Analysis on the Effect of LCR Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter)

  • 김재철;권영목
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.45-52
    • /
    • 2006
  • 본 논문에서는 H-bridge cascaded 7-level 인버터로 구동되는 고압 유도전동기에서 발생하는 과도과전압 저감을 위한 LCR 필터의 효과를 분석하였다. 인버터에서 발생하는 스위칭 서지 전압은 유도전동기 입력단자에서 과도과전압을 발생시킨다. 이 과도과전압은 고압 유도 전동기의 고정자 권선에 심각한 전압스트레스를 주어 전동기 절연사고를 발생시키는 주요원인이다. 과도과전압의 영향은 저압유도 전동기 보다 고압 유도전동기에서 더욱더 심각하게 발생한다. 이러한 과도과전압을 저감하기 위한 방안으로 LCR 필터를 선택하였으며, 필터를 인버터 출력단자에 연결하여 과도과전압 스트레스와 링잉을 저감한 것을 전동기 단자에서 전압파형과 고조파 스펙트럼을 통하여 증명하였다. 시뮬레이션은 전자계과도해석 프로그램인 EMTP(Electromagnetic Transients Program)을 사용하였다.

뇌격전류 측정의 정확도에 영향을 미치는 요인 (Factors Affected the Accuracy of Lightning Current Measuring System)

  • 이복희;장근철;강성만;엄주홍;정길조;심응보;우정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1674-1676
    • /
    • 2003
  • The factors affecting the accuracy of lightning current measuring system are figured out the materials and length of down-conductor, and impedance matching between grounding resistance and characteristic impedance of cable. The cable with the low characteristic impedance used to transfer the lightning current from the top of the tower is too long to measure the waveform of lightning current, exactly. Especially, the height of the tower can cause the change of front time and magnitude of lightning stroke current. Basically, in this experiment. It was found that the magnitude and rise time of the lightning current are extremely dependant in the length of down-conductor in lightning current measuring system.

  • PDF

VLF를 활용한 전력케이블 진단 시뮬레이터 구현 (Implementation of Power Cable Diagnostic Simulator using VLF)

  • 김국;어익수
    • 한국산학기술학회논문지
    • /
    • 제21권8호
    • /
    • pp.593-602
    • /
    • 2020
  • 국내 공장이나 지중에 설치되어 있는 전력 케이블은 제조과정, 설치, 사용 중의 환경여건에 따라 사고가 발생할 수 있는 필연성을 갖고 있다. 전력 케이블에서 사고가 일어났을 때 막대한 경제적 손실과 사회적 혼란을 야기할 수 있어 이를 미연에 방지하고자 진단을 통한 케이블의 예방관리의 중요성이 증대되고 있다. 이에 본 논문에서는 현장에서 발생 될 수 있는 케이블의 설치나 제조결함, 경년열화로 문제가 될 수 있는 부분을 모의하여 진단시료 케이블을 제작하였고, 최근 도입되어 적용되고 있는 VLF(Very Low Frequency)장비를 사용하여 유전정접(tan 𝛿 ; TD), 부분방전(Partial Discharge ; PD)시험을 실시하였고, 0.1Hz 주파수를 갖는 VLF전원을 가압을 한 후 HFCT(High Frequency Current Transformer)를 이용한 부분방전과 AC(상용주파)내압 장비를 이용하여 가압한 후 PD측정을 수행하였다. 그 결과, VLF를 통한 2.0U0 전압에서 B, C상 결함시료에서는 내부 부분방전을 측정할 수 있었으며 A상 정상시료에서는 0.5~2.0U0 전압에서 모두 노이즈로 측정되었다. 또한, 상용주파수의 AC(60Hz) 내압장비를 통한 1.5U0전압에서 측정하여 그 실효성을 검증하였다. 활선상태에서의 부분방전은 1.0U0의 사용전압에서 측정 되어지며, 장비를 설치할 때 위험성이 있고, AC내압장비는 부피나 무게 등에 의해 이동의 어려움이 있어 사선상태의 VLF를 통한 진단방법이 안전과 실효성이 있음을 알 수 있었다.