• 제목/요약/키워드: high speed motor

검색결과 1,904건 처리시간 0.026초

한국형 고속전철 차량소음 예측 및 부품 소음관리방안 (Noise Prediction of Korea High Speed Train (KHST) and Specification of Sub-components)

  • 정경렬;김경택;이병현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.917-923
    • /
    • 2002
  • KITECH and ODS performed a study of internal and external noise prediction of the KHST test train. The object of this study was 3 kind of cars; trailer car(TT2), motorized car(TM1) and power car(TP1) and the predicted noise was calculated for the two different driving speeds in free field and tunnel conditions. Data of carbody design and noise sources were delivered from each manufactures. Some of noise sources which were not available in project team, were chosen by experiences of ODS. Internal noise level of each car were predicted for two cases i.e, at 300 km/h and 350 km/h. In addition sound transmission path and dominant noise sources were also investigated of each section of car, which is circular shell typed part of whole carbody. In case of TT2, the dominating sound transmission path is floor in terms or structure-borne noise and air-borne noise. The main noise sources are structure-borne noise from the yaw-damper and air-borne noise from the wheel/rail contact, whereas the dominating sound transmission path of TM1 are floor and sidewall below the window in terms of structure-borne noise. The main noise sources of TM1 are structure-borne noise from motor/gear unit and the yaw-damper in the free field, and air-borne noise from the wheel/rail contact and structure-borne noise from motor/gear unit in the tunnel. Through the external noise prediction for the KHST test train formation, the noise form the wheel/rail contact is estimated as one of the major sources. In addition, the noise specification of sub-component was proposed for managing each sub-surpplier to reach the KHST noise requirement. The specification provide the sound power of machinery part and transmission loss of component of carbody structure. The predicted noise level in each case exceeded the required limit. Through this study, the noise characteristics of the test train were investigated by simulation, and then the actual test will be performed in near future. Both measured and calculated data will be compared and further work for noise reduction will be continued.

  • PDF

고속 전단 가공에서 페놀계와 인산계 산화방지제에 의한 PC/ABS 블렌드의 물성 변화 연구 (Effects of Phenolic and Phosphite Antioxidants on the properties for PC/ABS Blends during High-Shear-Rate Processing)

  • 이한기;김선홍;이형일;유재정;용다경;최석진;이승구;이기윤
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.266-271
    • /
    • 2014
  • Polycarbonate/Acrylonitrile-Butadiene-Styrene(PC/ABS) 블렌드의 분해효과를 조사하기 위해 고전단 압출 성형기의 스크류 회전속도와 전단시간의 함수로 PC/ABS의 물성변화에 영향을 미치는 산화방지제의 효과를 연구하였다. 인산계 산화방지제로 Tris-(2,4-di-tert-butyl-phenyl phosphate) (이후 A1로 명명) and Bis(2,4-dicumylphenyl) pentaerythritol diphosphite(이후 A3로 명명)가 사용되었고, 페놀계 산화방지제는 Octadecyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl) propionate(이후 A2로 명명)가 사용되었다. 열적 물성은 TGA를 통해 측정되었고 고속 전단 가공 후 크게 감소하였다. 산화방지제 A3가 포함된 PC/ABS 블렌드는 다른 산화방지제에 비해 스트레스로 유발된 degradation과, 열적 degradation이 지연되었다. 고속 전단 가공 후 UTM을 사용한 기계적 물성 또한 산화방지제 종류에 따라 각각 감소하였고, 특히, 신율의 경우 크게 감소하는 거동이 나타난 것에 비해 인장강도의 변화는 매우 적었다. 스크류 회전속도 1000 rpm, 전단부하 시간 20초 조건에서의 신율로 예를 들면, 고속 전단 가공하기 전 신율인 148%에서 A1은 91.6%, A2는 63%, A3은 131%로 감소하였다. 형태학적 물성을 알기 위해 SEM을 사용하여 PC/ABS의 분산상을 조사하였고, 스크류 회전속도와 하중이 작용한 기간이 증가함에 따라 그 크기 분포가 감소하였다. 따라서, 세 종류 산화방지제 모두 고속 전단 가공에서 스트레스로 유발되는 PC/ABS 블렌드의 degradation을 억제하고, 그 효과는 A3가 가장 뛰어난 것을 확인하였다.

열가소성 폴리올레핀으로 구성된 범퍼 후방 보 개발에 관한 연구 (Investigation of Development of Bumper Back-Beam Using a Thermoplastic Polyolefin)

  • 안동규;김세훈;박근성
    • 한국정밀공학회지
    • /
    • 제29권8호
    • /
    • pp.896-905
    • /
    • 2012
  • Recently, the application of the plastic material to automotive components and structures has steadily increased to satisfy demands on the saving of overall weight and the improvement of energy efficiency. The objective of this paper is to investigate the development of a bumper back-beam using a thermoplastic olefin (TPO). The bumper back-beam was designed to be manufactured from the injection molding process. In order to obtain a proper design of the bumper back-beam, three-dimensional finite element analyses were performed for various design alternatives. Stress-strain curves for different strain rates were measured by high speed tensile tests of the TPO to consider strain rate effects in the FEA. The influence of the sectional shape and the rib formation on the contact force-intrusion curves, the deflection and the energy absorption rate of the bumper back-beam was examined. From the results of the examination, a proper design of the bumper back-beam was acquired. The bumper back-beam consisting of TPO was fabricated from the injection moulding process and the vibration welding. Pendulum crash tests were carried out using the fabricated bumper back-beam. The results of the tests showed that the designed bumper back-beam can satisfy requirements of the federal motor vehicle safety standard (FMVSS). Through the comparison of the previously designed bumper back-beam with the newly designed bumper back beam, it was noted that the weight of the designed bumper back-beam is lighter than that of the previously designed bumper back beam by nearly 16 %. In addition, it was considered that the newly designed bumper back beam can improve recycling of the bumper back-beam.

SRM의 최대 토크 운전을 위한 자기동조 제어 (Maximum Torque Operation of SRM by using a Self-tuning Control Method)

  • 서종윤;김광헌;장도현
    • 전력전자학회논문지
    • /
    • 제9권3호
    • /
    • pp.240-245
    • /
    • 2004
  • 본 연구에서는 SRM의 최대 토크 운전을 위한 자기동조 제어방법을 연구하였다. SRM은 비선형적인 특성이 강하여 해석적인 방법으로 특성을 고찰하거나 속도 및 토크 제어가 어려운 단점이 있다. 따라서 본 논문에서는 최대 토크 운전을 위한 적절한 턴-온/오프각 제어를 자기동조방식(self-tuning method)에 의해 결정하는 방식을 제안하였다. 그리고 턴-온/오프각을 제어하기 위해 귀환되는 신호는 각각 엔코더 펄스수와 상전류의 증분값을 사용하였으며, 운전 중에 스스로 적절한 턴-오프각을 먼저 추종하고 다음으로 턴-온각을 추종하게 된다. 턴-온/오프각은 서로 종속적인 관계에 있으므로 최대 토크 값을 유지하기 위한 턴-온/오프각을 실시간 자기동조방식으로 제어하였으며, 실험을 통해 제안된 방식이 타당함을 확인하였다.

수직 오리피스 이젝터의 혼합유동 및 산소전달 특성 (Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector)

  • 김동준;박상규;양희천
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.61-69
    • /
    • 2015
  • 본 논문은 수직 오리피스 이젝터의 혼합유동 및 산소전달 특성에 대한 실험적 연구를 목적으로 한다. 실험장치는 전동 모터-펌프, 오리피스 이젝터, 순환 수조, 공기압축기, 고속 카메라 시스템 그리고 제어 및 측정기기로 구성하였다. 측정된 구동유체 및 유입공기의 유량을 이용하여 유량비를 도출하였다. 이적터에서 분출된 혼합유동의 가시화를 통해 정성적 거동을 고찰하였으며, 용존산소 농도를 측정하여 총괄 산소전달계수를 도출하였다. 구동유체의 유량이 일정하고 압축기의 공기압이 높아지면 유량비와 산소전달계수는 증가하며, 압축기의 공기압이 일정하고 구동유체의 유량이 증가하면 유량비는 감소하지만 산소전달계수는 증가하였다. 기포의 크기에 따른 체류시간 및 확산도와 수직 혼합유동의 도달거리는 2 상의 접촉면적과 시간에 크게 영향을 미치기 때문에 산소전달율의 중요한 변수임을 유추할 수 있다.

드론용 동축 프로펠러 시험장치 개발 및 제자리비행 성능특성에 대한 실험적 연구 (Development of Coaxial Propeller Test Facility and Experimental Study on Hover Performance Characteristics for Drone)

  • 송연하;김덕관
    • 한국항공우주학회지
    • /
    • 제46권1호
    • /
    • pp.59-67
    • /
    • 2018
  • 본 논문에서는 저 레이놀즈 동축 프로펠러의 제자리 비행 특성연구를 위한 시험장치 개발과정과 실험결과를 기술하였다. 상/하부 프로펠러간의 간격 변화에 따른 제자리 비행 성능측정이 가능하도록 시험장치를 설계하였다. 그리고 상/하부 프로펠러 각각의 추력, 토크, 회전수, 진동, 전류량을 측정할 수 있도록 장치를 구성하였다. 센서의 신호 수집을 위하여 자료획득시스템을 구축하고 LabVIEW 기반의 소프트웨어에서 모터의 제어와 신호 수집을 하였다. 단일 프로펠러의 지상회전 실험을 통한 성능 특성 데이터를 확보한 후, 동축 프로펠러 사이의 간격과 상/하부 직경의 차이에 따른 성능 특성과 효율향상을 위한 실험을 진행하였다. 성능 실험분석 결과 동축 프로펠러 사이 간격이 로터 직경의 20~30%일 때 효율이 높은 것으로 확인되었으며, 그 이상일 경우는 큰 차이가 없었다. 상부 프로펠러의 직경이 하부 프로펠러의 직경보다 작을 경우가 다른 직경 조합에 비해 가장 높은 효율을 보였다.

공기분사 및 회전 롤러를 이용한 옥수수 포엽 제거장치의 시험 (Evaluation of an Air-jet and Roller Type Corn-husker)

  • 박회만;조광환;홍성기;이선호
    • Journal of Biosystems Engineering
    • /
    • 제35권3호
    • /
    • pp.163-168
    • /
    • 2010
  • With income growth and "well-being" trends, sales of corn has been increased recently. Corns are processed at processing facilities on the main production site. Corn processing steps include removing bract, steaming, vacuum packing, and storing. To replace manual corn bract removing, some bract removing machines were imported and used. However, the machines were abandoned shortly, because of high damaging ratio of corns. In this research, factors of successful bract removing was studied with rotating rollers and air-injection nozzles to develop corn bract removing system. The test device was composed of a cylindrical roller, an air spray nozzle, a regulator, and a motor. Designing factors were roller type, diameter of air spraying nozzle, spraying angle, and spraying pressure. The measured factors were bract removing rate and damaging rate. It was found that optimum cylindrical roller surface shape was cylindrical roller and linear grove roller. This roller shape produced lowest damaging rate. Test results of the efficacy of preprocessing showed that the air spraying after preprocessing produced highest performance. The rotational speed and inclination of the roller didn't affect the bract removing performance. Optimum injection angle of the air jet nozzle was $70^{\circ}$. To increase bract removing rate and to reduce corn damage, required injection pressure and injection nozzle diameter were decided to less than 0.4 MPa and 2.5 mm, respectively. More than 3 times of nozzle passing produced good bract removing performance and there were no significant difference between the number of passing times.

냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향 (Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

냉매 내 공기혼입에 따른 에어컨 시스템의 냉각성능 저하 (Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제34권6호
    • /
    • pp.470-475
    • /
    • 2009
  • This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.

Flame Spread Mechanism of a Blended Fuel Droplet Array at Supercritical Pressure

  • Iwahashi, Takeshi;Kobayashi, Hideaki;Niioka, Takashi
    • 한국연소학회지
    • /
    • 제7권1호
    • /
    • pp.15-22
    • /
    • 2002
  • Flame spread experiments of a fuel droplet array were performed using a microgravity environment. N-decane, 1-octadecene, and the blends (50% : 50% vol.) of these fuels were used and the experiments were conducted at pressures up to 5.0 MPa, which are over the critical pressure of these fuels. Observations of the flame spread phenomenon were conducted for OH radical emission images recorded using a high-speed video camera. The flame spread rates were calculated based on the time history of the spreading forehead of the OH emission images. The flame spread rate of the n-decane droplet-array decreased with pressure and had its minimum at a pressure around half of the critical pressure and then increased again with pressure. It had its maximum at a pressure over the critical pressure and then decreased gradually. The pressure dependence of flame spread rate of 1-octadecene were similar to those of n-decan, but the magnitude of the spread rate was much smaller than that of n-decane. The variation of the flame spread for the blended fuel was similar to that of n-decane in the pressure range from atmospheric pressure to near the critical pressure of the blended fuel. When the pressure increased further, it approached to that of 1-octadecene. Numerically estimated gas-liquid equilibrium states proved that almost all the fuel gas which evaporated from the droplet at ordinary pressure consisted of n-decane whereas near and over the critical pressure, the composition of the fuel gas was almost the same as that of the liquid phase, so that the effects of 1-octadecene on the flame spread rate was significant.

  • PDF