Browse > Article
http://dx.doi.org/10.5307/JBE.2009.34.6.470

Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant  

Moon, Seong-Won (Department of Bio-Industrial Machinery Engineering, Institute of Agriculture and Life Science, Gyeongsang National University)
Min, Young-Bong (Department of Bio-Industrial Machinery Engineering, Institute of Agriculture and Life Science, Gyeongsang National University)
Chung, Tae-Sang (Department of Machinery Engineering, Jinju National University)
Publication Information
Journal of Biosystems Engineering / v.34, no.6, 2009 , pp. 470-475 More about this Journal
Abstract
This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.
Keywords
Air conditioning system; Refrigerant charge; Diagnosis of air conditioner;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Kwon, K. H., J. W. Jeong, J. H. Kim and C. H. Choi. 2006. Development of cold chain system using thermal storage with low-energy type. Journal of Biosystems Engineering 31(3):161-167. (In Korean)   과학기술학회마을
2 Lee, G. H., J. D. Jung, K H. Choi and J. Y. Yoo. 1998. An experimental study on the performance of automobile air conditioning system with variations of charging conditions. Transactions of Korea Society of Automotive Engineers 6(2): 203-211. (In Korean)   과학기술학회마을
3 Kang, G. C., Y. J. Kim, Y. S. Ryou and Y. Paek. 2002. Development of heating and cooling system with heat pump for nutrient solution bed in greenhouse. Joumal of the Korean Society for Agricultural Machinery 37(6):501-512. (In Korean)
4 Kang, Y. K, C. S. Han and D. H. Keum. 2007b. Drying and low temperature storage system for agricultural products using the air to air heat pump (2) - Performance of low temperature storage for apples -. Journal of Biosystems Engineering 32(2):101-108. (In Korean)   과학기술학회마을   DOI
5 Kang, Y. K, C. S. Han and D. H. Keum. 2007a. Drying and low temperature storage system for agricultural products using the air to air heat pump (1) - drying performance -. Journal of Biosystems Engineering 32(1):20-29. (In Korean)   DOI   ScienceOn
6 Suh, E. K. and O. N. Ha. 2003. Performance characteristics of heat exchanger for the automobile air-conditioner. Journal of Research Institute of Energy and Resources Technology 25(2):119-133. (In Korean)
7 Kim, C. W. 2005. Automotive Air Conditioner. pp. 199-214. Joongwonsa, Seoul, Republic of Korea. (In Korean)
8 Moon, S. D., Y. B. Min, S. W. Moon, D. H. Kang and T. S. Chung. 2008. Effect of refrigerant charging variation on temperature and pressures of refrigerant circulation line for air conditioner. Journal of Agriculture and Life Science in Gyeongsang National University 42(3):29-34. (In Korean)