• Title/Summary/Keyword: high reliability

Search Result 6,440, Processing Time 0.034 seconds

A Study on the Reliability Improvement of LRT(Light Rail Transit) (경량전철시스템 신뢰성 향상방안)

  • Kim Jong-Gurl;Han Suk-Yun;Jun Bong-Roong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.11a
    • /
    • pp.269-276
    • /
    • 2004
  • Special, high technology developments and systems improvements become more necessary as the industrial society is becoming complex. When some systems are developed, it is common that developed systems have low-reliability in infant period. Some developed systems need tests to improve their reliability up to the respected level before adapting them. This paper aims at showing the testing program including the reliability growth model for reliability improvement of the Light Rail Transit

  • PDF

Tolerance Intervals for Expected Time at the Given Reliability and Confidence Level (신뢰도와 신뢰수준을 고려한 기대수명 공차구간 설정에 관한 연구)

  • Choi Sung woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.7 no.2
    • /
    • pp.73-83
    • /
    • 2005
  • This paper is to propose tolerance intervals for expected time at the given reliability and confidence level for continuous and discrete reliability model. We consider guaranteed - coverage tolerance intervals, that is, reliability - confidence level tolerance intervals. These proposed methodologies can be applied to any industrial application where the customer's operating specification require a high level of reliability.

Effect of Water Temperature on Generation of Ion Migration (이온 마이그레이션 발생에 대한 수분온도의 영향)

  • Lee Deok Bo;Kim Jung Hyun;Kang Soo Keun;Kim Sang Do;Jang Seok Won;Lim Jae Hoon;Ryu Dong Soo
    • Journal of Applied Reliability
    • /
    • v.5 no.2
    • /
    • pp.261-272
    • /
    • 2005
  • In evaluation of electronic reliability on the PCB(Printed Circuit Board), electrochemical migration is one of main test objects. The phenomenon of electrochemical migration occurs In the environment of the high humidity and the high temperature under bias through a continuous aqueous electrolyte. In this paper, the generating mechanism of electrochemical migration is investigated by using water droll acceleration test under various waters. The waters used in the water drop test are city water, distilled water and ionic water. It found that the generated velocity of electrochemical migration depended on the temperature of water and the electrolyte quantity which included in the various waters.

  • PDF

Effect of Water Temperature on Generation of Ion Migration (이온 마이그레이션 발생에 대한 수분온도의 영향)

  • Lee Deok Bo;Kim Jung Hyun;Kang Soo Keun;Kim Sang Do;Jang Seok Won;Lim Jae Hoon;Ryu Dong Soo
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.339-348
    • /
    • 2005
  • In evaluation of electronic reliability on the PCB(Printed Circuit Board),electrochemical migration is one of main test objects. The phenomenon of electrochemical migration occurs In the environment of the high humidity and the high temperature under bias through a continuous aqueous electrolyte. In this paper, the generating mechanism of electrochemical migration is investigated by using water drop acceleration test under various waters. The waters used in the water drop test are city water, distilled water and ionic water. It found that the generated velocity o of electrochemical migration depended on the temperature of water and the electrolyte quantity which included in the various waters.

  • PDF

Control of Connectivity of Ni Electrode with Heating Rates During Sintering and Electrical Properties in BaTiO3 Based Multilayer Ceramic Capacitors

  • Yoon, J.R.;Shin, D.S.;Jeong, D.Y.;Lee, H.Y.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.181-184
    • /
    • 2012
  • $BaTiO_3$ based multilayer ceramic capacitors with Ni electrodes can be explained as 2-2 composites with different thermal expansion coefficient and sintering behaviors. To achieve the high capacitance and reliability of MLCCs, a homogenous Ni electrode configuration with high connectivity is required. We controlled the heating rates during sintering to achieve densification by suppressing grain growth. Experimental results revealed that a large heating rate gave high connectivity of Ni electrode, high capacitance, small dissipation factor, high breakdown voltage, and high reliability of MLCC chips.

A Comparison of the Failure Mechanism for High Power Converted White LEDs(3W) (고 출력 백색 변환용 LED(3W용)의 고장메커니즘 비교)

  • Yun, Yang-Gi;Jang, Jung-Sun
    • Journal of Applied Reliability
    • /
    • v.12 no.3
    • /
    • pp.177-186
    • /
    • 2012
  • This paper presents a comparison of the failure mechanism for high power converted white LEDs(3W) with the commercially available YAG:Ce and silicate phosphor. We carry out the normal aging life test for 10,000 hours, the high temperature aging test for 8,000 hours, the high temperature and humidity aging test for 8,000 hours and the current aging testing for 5,000 hours. The optical and electrical parameters of LEDs were monitored, such as lumen, correlated color temperature (CCT), chromaticity coordinates(x, y), thermal resistance, I -V curve and spectrum intensity. The stress induced a luminous flux decay on LED in all experiments and causes a failure. So we try to find out what's a main failure mechanism for a high power LED.

High-Speed and High-Reliability Data Transmission Technology for Next Generation Under-Water Communications (차세대 수중통신용 고속 고품질 데이터 전송 기법)

  • Jeong, Jin-hee;Choi, Duk-gun;Jung, Ji-won
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.448-453
    • /
    • 2005
  • For under-water communication system, due to limit of bandwidth and reflect of under-water wave, it is difficult to implement high-reliability high-speed digital communication system. To apply high-reliability and high-speed communication system for under-water system, the efficient combine the channel design with the use of multiple transmit and/or receive antennas. Therefore this paper analyze the space time coded system for under-water communication environment.

  • PDF

Reliability and Validity of the Balancia using Wii Balance Board for Assessment of Balance with Stroke Patients (뇌졸중 환자들의 균형평가를 위한 Balancia 프로그램의 신뢰도와 타당도)

  • Park, Dae-Sung;Lee, Dong-Yeop;Choi, Sung-Jin;Shin, Won-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2767-2772
    • /
    • 2013
  • Balance is the foundation for all active daily livings. Evaluation of balance has been conducted to measure postural sway of center of pressure(COP). The purpose of this study is to introduce the Balancia and to examine the validity and inter-, intra-reliability for measure of balance with stroke patients. COP was measured by Wii balance board. The subjects Participated in this study were 39 stroke patients. Intra- and inter-reliability was examined using intraclass correlation coefficient(ICC) with 95% confidence interval. In the result of intra- and inter-reliability, all COP parameters of postural sway showed high to very high reliability with ICC=.793-.939 and ICC=.791-.955. Validity was determined by correlation with Accusway force plate. There were high validity with ICC=.851-.955 between tools. According to these results, the Balancia showed high validity and reliability. It is a useful clinical tool for evaluating balance in stroke patients.

Reliability and Validity of Balancia 2.5 Program Using Wii Balance Board for Assessment of Static Balance Ability

  • Ho Kim;Dong-Min Kum;Won-Seob Shin
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.488-492
    • /
    • 2022
  • Objective: The purpose of this study is to find out the reliability and validity of the newly updated Balancia 2.5 program using Wii balance board through equipment that can measure center of pressure data with the precision. Design: Cross-sectional study Methods: Twenty-seven healthy adults participated in the study. The subjects were assessed for static balance ability by Accusway, and were assessed for static balance ability on Wii balance board connected to theBalancia 2.5 program.To limit postural fluctuations due to stare, the subjects were asked to look at a 15 cm dot drawn 3 m in front of them for 30 seconds with their eyes open. Static balance ability data such as path length and sway velocity were extracted from all measurement tools.Intra-rater and inter-rater reliability and validity were extracted through intraclass correlation coefficient (ICC) and 95% confidence interval (CI). Results: The intra-rater reliability that the same rater shows consistent results through test-retest was a high level at ICC=0.968 (0.926~0.986), and inter-rater reliability that the requires consistent results even when measured by different raters was a high level at ICC=0.943 (0.870~0.975). The validity was a high level at ICC=0.948 (0.881~0.977), which shows whether the measurement tool is properly measuring what it is intended to measure. Conclusions: The Balancia 2.5 program, newly updated through this study, proved to be a program with high reliability and validity in evaluating static balance ability like the existingBalancia 2.0 program.

Development of High Efficiency Boiler with High Safety (안전성이 높은 고효율 보일러 개발에 관한 연구)

  • Jung, Won
    • Journal of Applied Reliability
    • /
    • v.11 no.1
    • /
    • pp.83-95
    • /
    • 2011
  • Boiler efficiency has a direct impact on energy consumptions, which results in lower cost of operations and services. Usually high efficiency boilers are regarded as boilers with an efficiency of greater than 90%. However, it is likely that normal boilers are running at significantly lower efficiencies than this. This paper presents a process of developing a highly efficient energy consumption boiler. We adopt direct heat method while normal boilers are designed as indirect heat method. The submerged combustion method is considered to design for very high efficient boiler.