THE TRACKING CHARACTERISTICS BY THE DIFFERENT CROSSLINKED DENSITY OF SILICONE RUBBER MATERIAL USED FOR OUTDOOR INSULATION (옥외용 실리콘 고무재료의 가교도에 따른 내트랙킹 특성)

  • Kim, D.W.;Lee, C.Y.;Hong, J.Y.;Baek, J.H.;Lee, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1058-1060
    • /
    • 1995
  • In this paper, we studied the tracking characteristics of silicone rubbers that differed in the degree of crosslinking. As the tracking method, we adopted ASTM D 2303 and Merry-Go-Round(MGR) test method. It was found that the higher the degree of crosslinking, the better tracking characteristics. In these two test methods, specimens showed similar tendency of performance variation according to the degree of crosslinking. However the degradation phenomena were very different. As for MGR method, only the color of specimens' surface changed without any erosion or tracking path on them. On the contrary, the specimens subjected to ASTM D 2303 test method showed severe erosion.

  • PDF

A Study on the Life Assessment for Turbine Rotor by the In-field Electrochemical Method (터빈 수명평가를 위한 전기화학법의 현장적용에 관한 연구)

  • Chang, S.H.;Kim, J.H.;Song, G.W.;Yu, H.S.
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.13-18
    • /
    • 2000
  • Nowadays, 60 percent of thermal power plants already have been operated over their own design life. These operations of old power plant over their design life have caused a fracture accident of degradation a loss of economic and human. Therefore, the new life assessment and prediction technology is necessary to improve the safety and reliability of high pressure and high temperature power plant facilities. In this paper, innovative electrochemical test method have been used and results have been compared to the conventional test. Finally, the electrochemical test is applied to the in-field HP turbine and a database is currently in progress for the development of the life assessment standard and procedure.

  • PDF

Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable (XLPE 특고압 전력케이블의 절연 진단)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

Test bed for Advanced function of Smart Inverter and Results Based on Real-Time Simulation Platform (실시간 시뮬레이터 기반의 스마트 인버터 제어기능 시험 환경 구축 및 시험 결과)

  • Sim, Junbo;Ban, Minho;Lim, Hyeonok;Cho, Seong-Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.107-114
    • /
    • 2021
  • High penetration of renewable energy generators causes unnecessary investment for power system facilities. Especially with Korean government policies such as Renewable Energy 3020 and Inter-connection support Responsibility of KEPCO for 1 MW DERs, the applications of DER interconnection in distribution system have been increasing. To save the investment, smart control functions for DERs are required and the test bed for the inverters which have not been prepared are necessary to insure DER inter-connection stability. For this, test bed for advanced functions of a smart inverter has been constructed and the tests for necessary functions have been implemented. In this paper, the test bed and environment as well as specifications are introduced and the test results for the validation of the functions are analyzed.

Substation Power Quality Test of Hanvit 350 running (한국형 고속열차 주행시 전철변전소 전력품질 시험)

  • Lee, Tae-Hyung;Park, Choon-Soo;Im, Young-Chan;Choi, Seong-Hoon
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1479-1481
    • /
    • 2007
  • It is important to evaluate the power quality at a substation when a test train is running. Especially, the Korea Electric Power Company(KEPCO) restrict the power quality generated from the electrical train within limited value. So, this paper represents the results of the power quality test when Hanvit 350 is running at the KTX high speed line and the assessment.

  • PDF

A Study on the Temperature Characteristics of High Voltage Power Cable for Hybrid Electric Vehicle (하이브리드 자동차용 고압 케이블의 온도 특성에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Woo;Kim, Dong-Ook;Gil, Hyoung-Jun;Kim, Hyang-Kon;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제57권3호
    • /
    • pp.338-342
    • /
    • 2008
  • Hybrid Electric Vehicle(HEV) is driven by an internal-combustion engine and an electric motor. It is a combination of an internal-combustion engine and several electrical equipments which use a high voltage battery, an electric motors, an inverter and others. But there is not any separate detailed enforcement regulations for high voltage electric appliances in the existing vehicle-related safety standards. So, test standards suggestion as well as test technique development need to be done for ensuring electrical safety, for an electric motor, a high voltage battery, a(n) inverter/converter and an electric power transmission units and other equipments to ensure the safety of high voltage electric appliances which is the HEV key electrical component. In this paper, We are to provide helpful data to support test technique development and test standard establishment for HEV design and electrical safety security by the following methods; by measuring the voltage, the electric current, and the frequency of HEV, by analyzing electrical characteristics of high voltage electric appliances, and by analyzing temperature characteristics of the electrical current among the analyzed electrical characteristics by thermal imagining cameras.

The Analysis of High Frequency Signal for 7tonf-class Power Pack System of KSLV-II (한국형발사체 7톤 파워팩 시스템 고주파 신호 분석)

  • So, Younseok;Yi, Seungjae;Lee, Kwangjin;Kim, Seunghan;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제20권3호
    • /
    • pp.96-102
    • /
    • 2016
  • The 7tonf-class power pack test at turbopump test facility in Naro space center was performed for confirmations of starting/running/ending operation characteristics before 7tonf rocket engine hot-firing test. The dynamic pressure mounted on a combustion chamber of gas generator is measured under 0.2 bar which does not conditioned to the unstable combustion. The analysis results of RPM and acceleration sensors mounted on the turbopump, the power pack test was performed to the estimated RPM with the stable combustion.

The estimation of uncertainty in high-voltage measuring system used in high-power tests (대전력시험에서 고전압 측정시스템의 불확도 평가)

  • Suh, Yoon-Taek;Kim, Maeng-Hyun;Kim, Dae-Won;Jeong, Joo-Young;Kang, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.348-350
    • /
    • 2002
  • In the high-power tests to be performed on electrical apparatus as switchgears, transformers, insulators, cable and so on the results of tests on these apparatus are extremely important to evaluate the performance of test object. The reliability of the results depends on the reliability of measuring systems used in the laboratories where tests are performed. This paper introduces factors of uncertainty and describes estimation of uncertainty in high-voltage measuring system used in high-power testing LAB. 1 in KERI.

  • PDF

High Power Microwave Resonant Ring (고출력 마이크로파 Resonant Ring)

  • Park, S.S.;Park, S.W.;Kim, S.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1275-1277
    • /
    • 1995
  • We designed and constructed an extremly high power s-band traveling wave resonator for the test of high power microwave components using 80MW pulsed klystron with $4{\mu}s$ pulse width. The 10dB directional coupler for the input power coupling was used, and the ring consists of phase shifter, tuner, H-band, and other microwave components. The designed total electrical length of the system is 10 times of the waveguide wavelength, ${\lambda}_g$=15.3cm, and the measured total insertion loss is 0.15dB. The low power test measurment showed the power multiplication of 14.69. The design goal is to achieve the peak power of 300MW, pulse width $4{\mu}s$ with 30 pulse repetition rate. In this article we discuss the treveling wave resonant ring constructed at the PAL laboratory together with the test results.

  • PDF

A Twin Symbol Encoding Technique Based on Run-Length for Efficient Test Data Compression

  • Park, Jae-Seok;Kang, Sung-Ho
    • ETRI Journal
    • /
    • 제33권1호
    • /
    • pp.140-143
    • /
    • 2011
  • Recent test data compression techniques raise concerns regarding power dissipation and compression efficiency. This letter proposes a new test data compression scheme, twin symbol encoding, that supports block division skills that can reduce hardware overhead. Our experimental results show that the proposed technique achieves both a high compression ratio and low-power dissipation. Therefore, the proposed scheme is an attractive solution for efficient test data compression.