• Title/Summary/Keyword: high power property

Search Result 500, Processing Time 0.033 seconds

The Evaluation of Mechanical Property of X20CrMoV12.1 Boiler Tube Steels (X20CrMoV12.1강의 열화에 따른 기계적특성 평가)

  • Kim, B.S.;Lee, S.H.;Kim, D.S.;Jung, N.G.
    • Journal of Power System Engineering
    • /
    • v.8 no.3
    • /
    • pp.18-22
    • /
    • 2004
  • Boiler is one of the most important utilities providing steam to turbine in order to supply mechanical energy in thermal power plant. It is composed of thousands of tubes for high efficient heat transfer. The material for boiler tubes is used in such high temperature and pressure condition as $540^{\circ}C$, 22MPa. The boiler tube material is required to resist creep damage, fatigue cracking, and corrosion damages. 2.25%Cr-1Mo steel is used for conventional boiler tubes, and austenitenite stainless steel is used for higher temperature boiler tubes. But the temperature and pressure of steam in power plant became higher for high plant efficiency. So, the property of boiler tube material must be upgaded to fit the plant property. Several boiler tube material was developed to fit such conditions. X20CrMoV12.1 steel is also developed in 1980's and used for superheater and reheater tubes in supercritical boilers. The material has martensite microstructures which is difficult to evaluate the degradation. In this thesis, degrade the X20CrMoV12.1 steel at high temperatures in electric furnace, and evaluate hardness with Vickers hardness tester and strengths with Indentation tester.

  • PDF

Uncertainty Modeling and Robust Control for LCL Resonant Inductive Power Transfer System

  • Dai, Xin;Zou, Yang;Sun, Yue
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.814-828
    • /
    • 2013
  • The LCL resonant inductive power transfer (IPT) system is increasingly used because of its harmonic filtering capabilities, high efficiency at light load, and unity power factor feature. However, the modeling and controller design of this system become extremely difficult because of parameter uncertainty, high-order property, and switching nonlinear property. This paper proposes a frequency and load uncertainty modeling method for the LCL resonant IPT system. By using the linear fractional transformation method, we detach the uncertain part from the system model. A robust control structure with weighting functions is introduced, and a control method using structured singular values is used to enhance the system performance of perturbation rejection and reference tracking. Analysis of the controller performance is provided. The simulation and experimental results verify the robust control method and analysis results. The control method not only guarantees system stability but also improves performance under perturbation.

A Robust Companding Scheme against Nonlinear Distortion of High Power Amplifiers (고출력 증폭기의 비선형 왜곡 특성에 강인한 Companding 기법)

  • Kim, Jae-Woon;Han, Seung-Woo;Shin, Yo-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11C
    • /
    • pp.1079-1086
    • /
    • 2007
  • In this paper, we propose a CCP (Companding Combined with Predistorter) scheme that maintains BER (Bit Error Rate) performance of systems, while effectively reducing PAPR (Peak-to-Average Power Ratio) of OFDM (Orthogonal Frequency Division Multiplexing) signals, independent of nonlinear property of HPAs (High Power Amplifiers). The proposed CCP scheme combines the conventional companding scheme proposed by the authors with the predistorter, in order to prevent degradation of BER performance caused by signal distortion from nonlinear property of the HPA and the compression property of the companding scheme. Hence, the proposed scheme effectively reduces the PAPR and simultaneously maintains the BER performance, independent of nonlinear property of the HPA. Simulation results showed that the proposed CCP scheme provides the lowest total degradation for all the modulations, when comparing with the companding scheme proposed by Wang and the clipping scheme.

Surge Property Analysis for Shorted Turn and Shorted Strand in High Voltage Motor Stator Winding (고압전동기 고정자권선의 턴단락 및 소선단락 써지시험 특성분석)

  • Kong, Tae-Sik;Kim, Hee-Dong;Lee, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2030-2031
    • /
    • 2007
  • This paper is purpose to understand the surge property for the shorted turn or shorted strand in high voltage motor stator windings. a shorted turn in high voltage motor windings causes a huge circulating current. and overheat windings, consequently burns the motor. a few shorted strands not cause winding failure immediately, but they increase the winding loss and temperature increase due to contact resistance. We carried out the surge test for three cases, normal winding, shorted turn winding and shorted strand winding. and we analyzed the test result.

  • PDF

A Survey on the Accidents of the Power Tillers in Korea (동력경운기 이용실태 조사분석(I) -농작업사고에 관하여-)

  • 홍종호;이채식;박호석;박판규;김경수;한성금
    • Journal of Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.58-66
    • /
    • 1980
  • A survey was conducted to investigate the power tiller accidents. Eight provinces were covered for this study, and 278 power tiller owners were selected randomly by computer random generator. The results are summarized as follows : A. Frequency of accident. (1) Each power tiller had an accident 0.98 times a year and once every 361 hours of use. Higher frequency of accident was found during the miscellaneous operations including the preparation for farming operation, and there was one accident for every 92 hours of use. (2) The power tiller, which are more than six years old, met an accident 1.19 times a year , or one every 311 hours of use. This value was the highest one compared with any other group. (3) Kerosene engine power tillers met an accident 0.97 times a year, or one every 389 hours of use. It was one tie a year, or once every 329 hours of use for diesel engine power tillers. (4) Among diesel-engine power tillers, 10 horse-power group showed a higher frequency tillers. B. Cause of accident (1) The accidents of power tiller were mainly of sefety , which occurred due to the lack of attention during the operation and 47.4% of the total accidents. The next was of accidental, which represented 26.3% of the total accidents. (2) High percentage of safety accidents occurred during the preparation for farming operation including adjustment. Most of the accidental accidents occurred during the transportation. (3) Lower frequency of accident was found in the power tiller group which were operated by the 21-40 years old operator in comparison with that of the power tiller which was operated by other age group. Power tillers which were operated by high school graduates experienced less accidents compared to other education levels. C. Damage by accident (1) Eighty seven pescents of the total accidents caused damage to the power tiller operator , and 13 % of the total accidents caused property damage only. (2) With regard to the damage to the power tiller operator, 73.8% of the total accidents caused light injury but 26.3% caused heavy injury. (3) Accidents which occurred during machine preparation , and farming operations caused minor injury to the operator, but the accidents during transportation caused heavy injury which cost more than 15 days for recovery. (4) Among the 39 accidents , which caused property damage 18 accidents were from the transportation . Among the total property damage accidents 53.8% were light one which cost only less than 1,000 won. (5) The property damage from each accident cost 1,017 won, on the average, with regard to the kinds of operation, the highest property damage occurred during transportation work, with the value of 2, 965won.

  • PDF

A Study on Thermostable Property of High Density Graphites Products with Expanded Graphite(1) (고밀도 팽창흑연 성형품의 내열 특성에 관한 연구(1))

  • Shin, Y.W.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.148-154
    • /
    • 2005
  • Thermostable property is one of most important characteristics of graphite. Commercial graphites sheet from expanded graphite is using for high-temperature elements. Nowadays the new plant with high performance is developed in field of chemical industries, so the need of graphites is increasing rapidly. In this paper, the thermostable properties of newly developed graphite products with high density is investigated. I introduced the graphite material which developed for these heat tests by NGF method in order to test thermostable properties by comparing to the results of the commercial graphite sheet from expanded graphite in same condition. Through measuring the weight reducing ratio with various specimens in some conditions, I investigated the thermostable characteristics of these materials. It is verified that the graphite products by NGF method has almost same or superior thermostable properties comparing with that of commercial graphite sheet. Also the graphite products by NGF method have possibility of being better in thermostable properties.

  • PDF

A Three-Phase AC-DC High Step-up Converter for Microscale Wind-power Generation Systems

  • Yang, Lung-Sheng;Lin, Chia-Ching;Chang, En-Chih
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1861-1868
    • /
    • 2016
  • In this paper, a three-phase AC-DC high step-up converter is developed for application to microscale wind-power generation systems. Such an AC-DC boost converter prossessess the property of the single-switch high step-up DC-DC structure. For power factor correction, the advanced half-stage converter is operated under the discontinuous conduction mode (DCM). Simulatanously, to achieve a high step-up voltage gain, the back half-stage functions in the continuous conduction mode (CCM). A high voltage gain can be obtained by use of an output-capacitor mass and a coupled inductor. Compared to the output voltage, the voltage stress is decreased on the switch. To lessen the conducting losses, a low rated voltage and small conductive resistance MOSFETs are adopted. In addition, the coupled inductor retrieves the leakage-inductor energy. The operation principle and steady-state behavior are analyzed, and a prototype hardware circuit is realized to verify the performance of the proposed converter.

3kW multi-string photovoltaic inverter design and simulation (3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션)

  • Lee, Jong-In;Yu, Beyng-Gyu;Yu, Gwen-Jong;Kim, Heung-Geun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

Dynamic Property of Ground Overvoltage Relay in Large Turbine Generator (대용량 터빈발전기에서 접지과전압 계전기의 동작 특성)

  • Kim, Hee-Dong;Lee, Young-Jun;Kim, Byong-Han;An, Joon-Young;Chae, Gyu-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1044-1047
    • /
    • 1999
  • This paper deals with the dynamic property of ground overvoltage relay in large turbine generator. Relay operation is based on detecting the fundamental voltages originating from the generator. Calculations of fault voltage and current are reviewed for the neutral ground resistance. The frequency, ampitude and waveform of individual harmonics were measured using power quality analyzer and memory hi-corder at the secondary side of ground potential transformer. The ac and dc high-potential tests were applied to evaluate the condition of generator, main and auxiliary transformer, isolated phase bus, potential transformer, surge capacitor and arrester.

  • PDF

Comparison of the Power Generating Characteristics of KIST- and FZ-Julich SOFCs (KIST와 FZ-Julich SOFC간의 출력성능 비교)

  • Jung, Hwa-Young;Lee, Sang-Cheol;Tietz, Frank;Kim, Hae-Ryoung;Lee, Hae-Weon;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.12
    • /
    • pp.703-709
    • /
    • 2007
  • We evaluate and compare the power generating characteristics of the anode supported SOFCs which have been fabricated from KIST and FZ-Julich in Germany. The performance and electrochemical property of each unit cell was characterized at the temperature range of $650-850^{\circ}C$ under same operating conditions and its microstructural property was thoroughly investigated via SEM after the performance test. According to the investigation, KIST- and FZJ SOFC showed different power generating characteristics in their temperature dependances due to their different design of electrode microstructure, especially the cathode microstructure. FZJ SOFC showed better performance at high temperature while showed lower performance at lower temperature. From the investigation about the correlation between microstructure and electrochemical property, we found that the superior performance of FZJ SOFC at high temperature was mainly due to its lower cathodic polarization resistance whereas better performance of KIST SOFC at lower temperature was mostly attributed to the lower ohmic resistance.