• 제목/요약/키워드: high pH

검색결과 9,420건 처리시간 0.054초

설문조사를 통한 연안개량안강망어업의 조업 실태 및 어선 구조 개선에 관한 의견 분석 (Analysis of the operation status and opinion on the improvement of fishing vessel structure in coastal improved stow net fishery by the questionnaire survey)

  • 장호영;김민선;황보규;오종철
    • 수산해양기술연구
    • /
    • 제57권4호
    • /
    • pp.316-333
    • /
    • 2021
  • In order to understand basic data for improving the fishing system and fishing vessel structure in coastal improved stow net fishery, a questionnaire survey and on-site hearing were conducted from May 10 to June 11, 2019 to analyze opinions on the improvement of operation status and fishing vessel structure. The questionnaire survey consisted of ten questions on the operation status of coastal improved stow net fishery and six questions on the improvement of fishing vessel structure, and the results of each question were analyzed by the region, the captain's age, the captain's career and the age of fishing vessel. As a result of analyzing opinions on the operation status of the coastal improved stow net fishery, it was found that the average time required for casting net was 32.8 to 33.0 minutes and that the average time required for hauling net was 41.0 to 42.2 minutes which took 10 to 12 minutes more than for casting net. The most important work requiring improvement during fishing operation (the first priority) were 'hauling net operation,' 'readjustment and storage of fishing gear,' and 'fish handling' and the hardest factor in fishing management were in the order of 'reduction of catch,' 'labor shortage' and 'rising labor costs.' The most institutional improvement that is most needed in coastal improved stow net fishery was an 'using fine mesh nets.' Most of the respondent to the questions on the experience in hiring foreign crews was 'either hiring or willing to hire foreign crews,' and the average number of foreign crews employed was found to be 2.3 to 2.4 persons. The most important reason for hiring (or considering employment) foreign crews was 'high labor costs.' The degree of communication with foreign crews during fishing operation were 'moderate' or 'difficult to direct work.' The most important problem in hiring foreign crews (the first priority) was an 'illegal departure.' As the survey results on the opinion of structural improvement of coastal improved stow net fishing vessel, the degree of satisfaction with fishing vessel structure related to fishing operation was found to be somewhat unsatisfactory, with an average of 3.3 points on a five-point scale. The inconvenient structure of fishing vessel in possession (the first priority), the space needed most for the construction of new fishing vessel (the first priority) and the space considered important for the construction of new fishing vessel (the first prioprity) was a 'fish warehouse.' The most preferred equipment for the construction of new fishing vessel were 'engine operation monitoring' and 'navigation safety devices.' The average size (tonnage class), the average horse power and the average total length of fishing vessel for proper profit and safety fishing operation was between 13.8 and 14.0 tonnes, 808.3 to 819.5 H.P. and 23.4 to 23.5 meters, respectively. The results of the operation status of coastal improved stow net fishery and the requirement for improving the fishing vessel structure are expected to be provided as basic data for reference when we build or improve the fishing vessel.

Newly Synthesized Phosphodiesterase 4 (PDE4) Inhibitor, DWP205505, Inhibits TNF-$\alpha$ Secretion and mRNA Expression

  • Lee, Suk-Kyeong;Lee, Sun-A;Byun, Hye-Sin;Cho, Mi-La;Kim, Wan-Uk;Park, Sung-Hwan;Cho, Chul-Soo;Joo, Young-Shil;Lee, Shin-Seok;Yoo, Eun-Sook;Son, Ho-Jung;Kim, Ho-Youn
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권1호
    • /
    • pp.106-112
    • /
    • 1999
  • The therapeutic potential of phosphodiesterase 4(PDE4) inhibitors in inflammatory diseases including some autoimmune diseases has been explored recently with some hopeful results. These PDE4 inhibitors are thought to show their anti-inflammatory effect by down-regulating tumor necrosis factor-a (TNF-$\alpha$) production in lymphocytes and macrophages. A high concentration of TNF-$\alpha$has been found in rheumatoid arthritis (RA) synovium and reducing TNF-$\alpha$using biological agents was proven to be an effective RA treatment. To test the possibility of using PDE4 inhibitors for RA treatment, the effects of a newly synthesized PDE4 inhibitor, DWP205505, on TNF-$\alpha$ and IL-10 production was tested in cells isolated from normal peripheral blood and rheumatoid arthritis synovial fluid. Cytokine production was assayed at the protein level by sandwich enzyme-linked immunosorbent assay (ELISA) and at the mRNA expression level by semi-quantitative RT-PCR. Another PDE4 inhibitor, RP73401, was used for comparison. DWP205505 and RP73401 had no harmful effect on cell viability up to 10 $\mu$M concentration during the 24 h culture period. DWP205505 as well as RP73401 significantly reduced TNF-$\alpha$ secretion from lipopolysaccharide (LPS)-stimulated peripheral blood mononuclear cells (pBMC) and synovial fluid mononuclear cells (SFMC). The effect of DWP205505 or RP73401 treatment on the mRNA expression of TNF-$\alpha$ was also studied in LPS-stimulated PBMC and SFMC. TNF-$\alpha$ mRNA expression was increased by LPS stimulation and both of the PDE4 inhibitors suppressed TNF-$\alpha$ mRNA expression. For interleukin-l0 (IL-l0), a little different results were obtained from PBMC and SFMC; IL-l0 secretion was unaffected by LPS stimulation and only minimally affected by both of the PDE4 inhibitors in PBMC. In unstimulated SFMC, DWP205505 and RP73401 slightly enhanced IL-10 secretion, while they reduced IL-l0 secretion from LPS-stimulated SFMC where IL-l0 secretion was a lot higher than unstimulated SFMC. These results suggest that the newly synthesized PDE4 inhibitor DWP205505 may have anti-rheumatoid arthritis activity.

  • PDF

땅콩 겉껍질 추출물의 주름개선 효능 및 화장품 제형에서 추출물의 안정성 평가 (Evaluation of Anti-wrinkle Effect of Peanut Shell Extract and Stability of the Extract in Cosmetic Products)

  • 한나래;이진영;김미향;최은영;안봉전;이유영;강문석;김현주
    • 대한화장품학회지
    • /
    • 제49권3호
    • /
    • pp.203-212
    • /
    • 2023
  • 본 연구는 땅콩의 부산물로 폐기되는 겉껍질의 기능성 화장품 소재 활용 가능성을 검토하고자 수행하였다. 땅콩 겉껍질 추출물의 DPPH 및 ABTS 라디칼 소거능 및 SOD 유사활성 IC50값은 각각 75.00, 46.33, 및 472.83 ㎍/mL으로 조사되었다. 땅콩 겉껍질 추출물 처리에 따른 MMP-1, MMP-3, 및 procollagen의 단백질 발현 정도를 측정한 결과, 농도 의존적으로 MMPs 단백질 발현량이 감소하였고, procollagen 단백질은 정상대조군 수준을 유지하였다. 주름 억제 효능을 검정한 결과, 추출물의 elastase 및 collagenase 저해활성 IC50 값은 각각 0.30 및 0.09 mg/mL로 양성대조군보다 낮았다. 땅콩 겉껍질 추출물에서 분리한 eriodictyol과 luteolin의 elastase 및 collagenase 저해 활성을 분석한 결과, 0.1 mg/mL 처리농도에서 eriodictyol과 luteolin은 각각 53.8 및 98.0%의 elastase 저해 활성을 보였으며, collagenase 저해 활성은 각각 60.1 및 72.5%로 조사되었다. 이를 통해 땅콩 겉껍질 추출물의 주름억제활성 유효성분은 luteolin일 것으로 사료되었다. 또한, 땅콩 겉껍질 추출물이 함유된 로션 및 크림 제형의 온도 조건 및 온도 순환에 따른 pH 및 점도를 측정한 결과, 유의미한 변화 없이 안정적인 제형임을 확인하였다. 이를 통해 땅콩 겉껍질 추출물이 주름 억제를 위한 화장품 소재로 적용 가능할 것으로 판단되었다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

인공광 식물공장에서 수경배양액 및 광질 조절이 상추 실생묘 생장에 미치는 영향 (Hydroponic Nutrient Solution and Light Quality Influence on Lettuce (Lactuca sativa L.) Growth from the Artificial Light Type of Plant Factory System)

  • 허정욱;박경훈;홍승길;이재수;백정현
    • 한국환경농학회지
    • /
    • 제38권4호
    • /
    • pp.225-236
    • /
    • 2019
  • 인공광 식물공장에서는 작물을 생산하기 위하여 일반적으로 화학비료 유래 무기성분을 포함하는 배양액을 시용하여 수경재배한다. 본 연구에서는 광질이 상이한 식물공장에서 관행의 무기배양액 일부 또는 전량을 유기배양액으로 대체할 수 있는 폐기 농업부산물 유래 유기배양액을 시용하여 수경재배하고 작물의 생장에 미치는 영향을 검토하였다. 청색, 적색 및 백색 LED를 1:2:1의 비율로 혼합한 혼합LED 및 관행의 형광등 조사 조건에서 적치마와 청치마 상추 실생묘를 35일간 수경재배한 결과, 적치마와 청치마 상추의 생체중 및 전개엽수 증가는 형광등을 조사한 Y구에서 통계적으로 유의하게 증가하였다. 그러나 유·무기 혼합배양액 처리구인 YK 및 YTJ에서는 오히려 혼합LED 조사구에서 증가하였다. 유기배양액 단용 또는 유·무기 혼합배양액 처리시 엽내 SPAD치는 두 실생묘 모두 Y구와 유사하거나 증가하는 경향을 나타내었다. 관행의 무기배양액인 Y구에서 배양액내 구성성분 중 가장 많은 양을 차지하고 있는 무기성분인 NO3-N은 재배 개시일에 약 97 mg/L으로, 적치마와 청치마 상추 실생묘에서 모두 재배기간이 경과함에 따라 감소하는 경향을 보였다. 적치마의 경우 재배종료시 각 처리구별 NO3-N 농도는 형광등 조사시 약 29 mg/L, 혼합LED 조사시 24 mg/L였으며, 청치마의 경우 형광등 조사시 약 26 mg/L, 혼합LED 조사시 47 mg/L로, 초기 투입량 대비 25~48% 정도의 양이 재배종료시까지 흡수되지 않고 남아 있었다. 재배개시일 NH3-N 농도는 Y구3-N 잔여량은 약 13%로 최대값을 나타내었다. 관행의 무기배양액내 질산태질소는 작물체에 흡수되어 생체중, 엽수 증가와 같은 지상부 생장을 좌우하는 주요 성분이지만 재배종료시까지 전량이 흡수되지 않고 남아 있는 것으로 보아 상추 수경재배시 배양액내 질산태질소의 초기 투입량을 조절할 필요성이 대두되었다. 연구결과 농업부산물 유래 유기배양액을 활용하여 적치마와 청치마 상추를 수경재배할 경우 유기배양액 단용보다 유·무기 혼합배양액 시용으로 유기배양액내 부족한 질소 성분을 무기질소로 보충할 수 있어 무기성분 사용량 저감이 기대된다. 또한 상추 실생묘의 양적생장 추이와 달리 엽내 색소합성이 관행 무기배양액보다 특정 유기배양액 단용 또는 혼용에 의해 유의하게 증가하는 것으로 보아 작물체내 물질합성량, 유기배양액 사용기간 및 재이용 등 유기배양액의 화학적 특성 변화에 대한 연구가 필요할 것으로 판단된다.

흑대추와 일반 건조대추의 추출 및 유산발효과정 중 특성 변화 (Comparison of Property Changes of Black Jujube and Zizyphus jujube Extracts during Lactic Acid Fermentation)

  • 어미선;김이슬;안승준;안준배;김광엽
    • 한국식품영양과학회지
    • /
    • 제41권10호
    • /
    • pp.1346-1355
    • /
    • 2012
  • 본 연구에서는 포제법(炮製法) 중 가장 대표적인 구증구포(九蒸九炮)법을 응용하여 steam, 건조, 저온 숙성 과정을 통해 만들어진 흑대추를 활용하여 추출 및 발효과정에 일어나는 주요 특성 변화를 건대추와 비교 분석하였다. 대추의 구증구포 과정을 통해 만들어진 흑대추를 활용하여 추출 및 유산발효를 진행하고, 이러한 과정 중에 나타나는 약리활성 성분의 변화를 건대추와 비교함으로써 흑대추 추출물의 효능을 확인하여 기능성식품 소재로 활용하기 위한 기초자료를 확보하고자 하였다. AOAC법을 이용하여 일반성분을 분석한 결과, 조단백질의 함량에는 유의적인 차이가 없었으나, 수분과 조지방, 조회분의 함량은 흑대추가 건대추보다 더 높은 것을 확인하였다. TLC와 HPLC를 이용하여 당 분석을 하였고, 건대추와 흑대추 모두 fructose, glucose, sucrose로 조성되어 있었고, 각 함량은 건대추는 5.60, 6.30, 9.04 g/100 g이었고, 흑대추는 9.76, 12.76, 2.95 g/100 g으로 건대추는 sucrose의 함량이 fructose와 glucose에 비해 높은 반면, 흑대추는 상대적으로 더 낮은 sucrose 함량을 나타냈다. 이러한 결과는 흑대추 제조를 위한 구증구포 과정 중 sucrose의 분해에 의한 것으로 판단된다. 유용성분이 추출될 수 있는 최적조건을 선정하기 위해 16개의 조건에서 추출수율을 측정하여 반응표면분석법(RSM)으로 최적 조건을 선정하였다. 건대추와 흑대추의 추출수율에 대한 회귀식의 결정계수값 $R^2$은 각각 0.3518, 0.3870으로 모델식이 적합하지 않았고, 이러한 결과는 추출조건에 따라 수율의 차이가 크지 않고, 추출 용매의 에탄올 비율이 증가할수록 수율이 증가하다가 80% 이상이 되면 수율이 급격히 감소하는 것이 원인인 것으로 판단된다. 따라서 Jeong 등(15)의 추출조건을 응용하여 건대추와 흑대추 추출물을 제조하였다. 추출물을 YL-3로 유산발효를 진행한 결과, 두 추출물 모두 배양 8시간 후부터 대수증식기가 시작되었고 24시간 배양 후 대수증식기가 종료되었다. 두 추출물의 초기 pH는 차이가 있었으나 8시간 배양까지 일정하게 유지되고 12시간 후부터 72시간까지 감소하는 유사한 변화 패턴을 보였고, 본 연구에서 사용한 건대추와 흑대추의 일반성분 함량 차이와 단당류 및 이당류 조성비의 차이가 유산균의 생육에 영향을 거의 미치지 않았음을 확인할 수 있었다. 대추 추출물의 유산발효에 의한 기능성 성분의 변화를 분석하고자 폴리페놀과 플라보노이드, free 라디칼 소거능을 측정하였다. 발효 전 건대추와 흑대추의 페놀성 물질의 함량을 분석한 결과 흑대추가 건대추에 비해 폴리페놀과 플라보노이드 함량이 유의적으로 높았으며, 발효 후 건대추의 폴리페놀 함량은 감소하였지만 플라보노이드 함량은 높은 증가율을 보였고, 흑대추는 발효 후 두 물질 모두 증가하였다. 이 결과를 통해 발효에 의한 페놀성 물질의 증가 가능성을 확인하는 것과 동시에 항산화 활성 및 생리기능의 향상을 예측할 수 있었고, 발효가 폴리페놀이나 플라보노이드 이외에도 많은 유효성분의 함량에 영향을 줄 것으로 기대되며 이와 관련된 연구가 지속되어야 할 것으로 생각된다. DPPH에 의한 라디칼 소거능 측정 결과, 흑대추의 발효 전 전자공여능은 74.72%로 건대추보다 더 높았고, 발효에 의한 DPPH free 라디칼 소거능의 유의적인 증가 효과는 없었다. 흑대추의 AEAC값이 1.06 mgAAeq/g으로 건대추에 비해 ABTS free 라디칼 소거능이 더 높았으나, 두 추출물 모두 발효에 의한 ABTS free 라디칼 소거능의 증가 효과는 없었다. 본 연구를 통해 구증구포에 의한 유용성분의 증가효과를 확인하였고, 건대추에 비해 영양성분 및 기능성 물질의 함량이 높은 흑대추를 주원료로 하여 유산균 발효공정을 도입함으로써 기능성물질의 증가 효과를 얻고 다른 대추 가공품과 차별화를 두고 제품의 품질을 향상시킬 수 있을 것으로 생각되며, 흑대추를 이용한 기능성 발효식품 개발에 이용될 수 있을 것으로 판단된다.

사설시조의 형태구조 연구 (A Study on the Morphological Structure of Sasul-Sijo)

  • 원용문
    • 한국시조학회지:시조학논총
    • /
    • 제23집
    • /
    • pp.161-188
    • /
    • 2005
  • 사설시조의 형태구조를 알아보기 위하여 시조의 형태를 종류별로 알아보고, 평시조, 엇시조, 사설시조를 형태적으로 구분하는 기준을 제시하였다. 그래서 평시조는 3장 6구 12절 이상이라 하였고, 엇시조는 3장 7구 14철 이상이라 하였고, 사설시조는 3장 8구 16절 이상이라 하였다. 이 연구는 1) 시조와 비시조, 2) 엇시조와 사설시조의 구분, 3) 서설시조의 구조 순으로 논의하였다. 1)에서는 2음보에 44조로 된 작품, 시조와 마찬가지로 3장의 형식은 갖추었지만 시조의 틀과 율조에 거리가 먼 작품, 쓰여진 말이나 어구가 우리말이 아니고 한시나 한문 문장으로 되어 있는 작품들은 비시조로 보아서 시조의 범주에서 제외시켰다. 2)에서는 엇시조는 형식을 장별로 보아 1구 2절 이상 늘어난 것만 엇시조로 간주하였고, 사설시조의 경우는 장별로 따졌을 때 어느 한 장에서 2구 4절 이상 늘어나면 사설시조로 간주하였다. 엇시조는 3장 중 어느 한 장에 구 한 개가 늘어난 경우, 사설시조는 3장 중 어느 한 장에 장 한 개가 늘어난 경우라 보면 된다. 3)에서 사설시조의 구조는 시조 1편이 3장 8구 16절 이상 된 것이라 하였다. 시조의 3장중에서 어느 한 장이 2구 4절 이상 늘어났으면 사설시조의 요건을 갖추었다고 본 것이다. 이러한 구절 첨가 현상은 (1) 초장에서 절(음보) 첨가 현상이 일어난 경우 (2) 중장에서 절 첨가 현상이 일어난 경우 (3) 종장에서 절 첨가 현상이 일어난 경우 (4) 초장과 중장에서 동시에 절 첨가 현상이 일어난 경우(5) 중장과 종장에서 동시에 절 첨가 현상이 일어난 경우 (6) 초 중 종 3장 모두에서 동시에 절 첨가 현상이 일어난 경우 등 다양하기 이를 데 없었다. 그리고 사설시조의 구절 수는 3장중 어느 한 장에서 최소 8절부터 최다 87절까지 늘어난 경우가 있어서 그 격차가 너무 크다는 것을 확인하였다.보 20, 검설뽕과 비슷한 성적을 나타내었으나 특이하게 pH 4.7로 단맛과 신맛을 함께 지니고 있었다. 7. NK-T2의 사료가치 검정평가 결과 개량뽕과 비교하여 유충기간과 화용비율, 견충비율은 거의 비슷하였으나, 단견중, 견층중. 2만두 수견량은 약간 떨어지는 결과를 보여 엽질이 비교적 우량하다고 평가되었다. 8. MK-T2로 사육한 5령3일차 누에의 아미노산을 분석한 결과 개량뽕을 급이한 대조구 간에는 서로 거의 유사한 아미노산 조성을 보여주었으나 MK-T2를 급이한 시험구의 경우 대조구와 비교하여 Leu에서 차이를 보여주었으며 Ile는 대조구에서는 검출되지 않았으나 MK-T2 시험구에서는 검출되었다. 9. MK-T2로 사육한 5령3일차 누에 에탄올 추출물의 약리효과 검정결과 누에 에탄을 추출물을 투여한 쥐에서 적출한 신장조직에 대한 HE 염색 및 조직면역화학염색 모두에서 조직학적 병징이 나타나지 않았고 $TGF-{\beta}1$ 단백 발현이 거의 확인되지 않는 수준으로 낮아졌다.며, 앞으로 LTCC가 발전 해야할 방향을 제시하고자 한다.e 121.9 ${\mu}g/100mg$ 함유되어 있었다. 버뮤다그라스(Cynodon dactylon)에서 발견되었다.이 설치 운영하고 있는 측정 장비에 의해 취득한 기상자료를 공동 활용하여 표출하면 더욱 상세한 자료의 획득과 활용이 기대되어 진다. 또한, 금번 논문에서는 산불위험지역의 격자점(15km)내에 최소한 1대의 AWS 설치방안을 제시하였지만, 금후에는 15km내에서도 능선, 계곡 등 구체적인 위치확정을 위한 선행연구가 실시되어야할 것으로 판단된다.의해 원고는 결과발생지인 미국법원의 재판관할을 강제할 수 없을 것이다. 지적재산권을 둘러싼 분쟁에 관한 재판관할과 국제법상의 판결의 승인 및 집행의 통일성을 기하기 위하여 2001년 1월 세계지적재산권기구(World

  • PDF

춘천지역 일부 여대생의 아침식사 빈도에 따른 BMI, 식행동 및 영양소 섭취상태 (Study on BMI, Dietary Behavior, and Nutrient Intake Status According to Frequency of Breakfast Intake in Female College Students in Chuncheon Area)

  • 김윤선;김복란
    • 한국식품영양과학회지
    • /
    • 제46권10호
    • /
    • pp.1234-1242
    • /
    • 2017
  • 본 연구는 춘천지역 일부 여대생 253명을 대상으로 아침식사 빈도에 따른 신체질량지수(body mass index, BMI), 식행동 및 영양소 섭취상태를 알아보고자 하였다. 본 연구에서는 아침식사를 주 5회 이상 섭취군과 4회 이하 섭취군으로 분류하였으며, 그 결과 아침 5회 이상 섭취군이 54.9%, 4회 이하 섭취군이 45.1%로 나타났다. 거주형태는 학교 주변에서 자취, 하숙하는 학생들이 가장 많았으며, 아침 5회 이상 섭취군은 부모님과 함께 생활하는 경우가 높게 나타났고, 4회 이하 섭취군은 자취, 하숙하는 경우가 높게 나타나면서 부모님과 함께 생활할수록 아침식사 빈도가 높고 혼자 생활할수록 아침식사를 하지 않거나 아침식사 빈도가 낮은 것을 알 수 있었다. 자신의 체형만족도는 아침 5회 이상 섭취군이 4회 이하 섭취군에 비해 자신의 체형만족도가 높은 것으로 나타났다. 아침 5회 이상 섭취군의 신장, 체중 및 BMI는 각각 $161.0{\pm}0.1cm$, $52.6{\pm}7.6kg$, $19.8{\pm}1.9kg/m^2$ 였으며, 4회 이하 섭취군은 각각 $160.7{\pm}0.1cm$, $57.1{\pm}11.8kg$, $21.5{\pm}3.4kg/m^2$로 나타났는데, 체중과 BMI에서 유의적인 차이를 나타내었다. BMI 분포를 보면 아침 5회 이상 섭취군은 저체중이 15.8%, 정상체중이 59.0%, 과체중이 15.8%, 비만이 9.4%였으며, 4회 이하 섭취군은 저체중이 13.2%, 정상체중이 43.8%, 과체중이 28.1%, 비만이 14.9%로 나타났다. 식행동 점수는 아침 5회 이상 섭취군이 4회 이하 섭취군보다 높게 나타나 규칙적인 식사패턴을 보였으며 '우유나 유제품을 매일 1잔 이상 마신다', '과일이나 과일주스를 매일 먹는다', '하루 세끼 규칙적으로 식사한다' 문항에서 유의적인 차이를 보였다. 영양소 섭취상태를 알아본 결과 1일 평균 에너지는 아침 5회 이상 섭취군이 1,545.8 kcal, 4회 이하 섭취군이 1,378.2 kcal로 나타났고, 탄수화물과 단백질은 아침 5회 이상 섭취군이 각각 218.8 g과 56.1 g, 4회 이하 섭취군이 188.1 g과 49.7 g으로 5회 이상 섭취군이 유의적으로 높게 섭취하였다. 또한, 비타민 A, 비타민 $B_1$, 비타민 $B_2$, 나이아신, 비타민 $B_6$, 인, 아연과 콜레스테롤 섭취량도 아침 5회 이상 섭취군이 4회 이하 섭취군에 비해 유의적으로 높게 나타났다. 에너지 필요추정량(EER)과 영양소의 권장섭취량(RNI)을 살펴보면 EER은 아침 4회 이하 섭취군(65.6%)이 5회 이상 섭취군(73.7%)에 비해 낮은 섭취율을 보였고, 비타민과 무기질에서는 조사대상자들이 비타민 $B_1$, 비타민 E, 인과 나트륨을 제외한 모든 영양소를 부족하게 섭취하고 있었다. 이 중 권장섭취량의 80% 이하로 섭취하는 영양소를 알아본 결과 아침 5회 이상 섭취군은 비타민 C, 엽산, 칼슘과 철이었으며, 4회 이하 섭취군은 비타민 A, 비타민 $B_2$, 나이아신, 비타민 $B_6$, 비타민 C, 엽산, 칼슘과 철로 나타나 아침식사의 빈도가 낮을수록 전체 식사에서의 영양소 섭취가 부족함을 알 수 있었다. 조사대상자의 에너지 섭취량에 대한 탄수화물, 단백질, 지방의 섭취비율은 56.4:14.6:27.7로 나타났으며, 아침식사 빈도에 따른 유의적인 차이는 나타나지 않았다. 또한, 아침식사 빈도와 상관관계가 있는 변인을 알아보기 위하여 다중회귀분석을 실시한 결과 거주상태가 가장 중요한 변인으로 작용하였다. 이상의 결과로부터 여대생들의 높은 아침결식률이 전체 식사의 영양소 섭취에도 영향을 미쳐 여대생들에게 아침식사의 중요성을 강조함과 동시에 아침식사 섭취를 통한 에너지 및 대부분의 영양소 섭취량을 증가시켜 다양하고 적절한 식사를 가능하게 해야 할 것이다. 한편 특정 영양소, 칼슘, 비타민 C와 철분 결핍의 우려가 심각해 이들 영양소들은 기존 식사에서의 섭취량을 양적으로 증가시키는 것과 동시에 질적으로 우수한 우유, 멸치, 녹색 채소류(브로콜리, 케일, 청경채 등), 과일, 육류 및 생선 등의 섭취를 유도하여 여대생들의 영양 상태 개선을 위한 꾸준한 노력도 필요할 것으로 보인다. 또한, 아침결식 문제를 해결하기 위한 방안으로 비자택 거주자들의 식생활 교육 강화 및 거주상태가 고려된 연구의 필요성을 제기하는 바이다.

미국신분류법(美國新分類法)에 의(依)한 답토양의 분류(分類)에 관한 연구 (Soil Classification of Paddy Soils by Soil Taxonomy)

  • 주영희;신용화
    • 한국토양비료학회지
    • /
    • 제11권2호
    • /
    • pp.97-104
    • /
    • 1979
  • 토양정밀조사결과 우리나라에서 밝혀진 235 개(個)의 토양통에 대하여 분류체계를 확립(確立)코저 미국(美國)의 신토양분류법에 준(準)하였는바 60개(個)의 아군으로 구분할 수 있었다. 그러나 수도재배기간중(水稻栽培期間中) 담수상태(湛水狀態)를 유지(維持)하게되는 답토양들은 신분류법(新分類法)에 분류기준(分類基準)이 확립(確立)되어 있지않아 토양형태적특성에 입각(立脚)하여 분류(分類)코저 할때 무리(無理)가 있음을 알 수 있었다. 답토양의 분류상(分類上) 문제시(問題視)된 것은 토양아군의 수준(水準)에서 18개(個)였으며 이들 새로운 아군에 대하여 분류기준(分類基準)을 설정(設定)(Setup)하였는 바 그 분류시안(分類試案)의 내용(內容)을 요약(要略)하면 다음과 같다. Anthro aquic, Aquic Udipsamments; 관개수(灌漑水)의 영향(影響)을 받아 표토(表土)로 부터 50cm이상(以上) 회색화작용(灰色化作用)을 받은 사질계충적토(砂窒系沖積土)이며 사두(沙頭)및 김천통등(金川統等)이 이에 속(屬)한다. Anthroaquic Udipsamments; 관개수(灌漑水)의 영향(影響)을 받아 표토(表土)로 부터 50cm 이내(以內)에서 회색화작용(灰色化作用)을 받은 사질계충적토(砂窒系沖積土)로 백수통(白岫統)이 이에 속(屬)한다. Halic Psammaquents; 개답년대(開畓年代)가 오래되지 않은 간척지의 염해답으로 낙천통이 이에 속(屬)한다. Anthroaquic, Aquic Udifluvents; 관개수(灌漑水)의 영향(影響)을 받아 표토(表土)에서 50cm이상(以上) 회색화작용(灰色化作用)을 받은 사양질 및 식양질계 충적토로 마영통(馬嶺統)이 이에 속(屬)한다. Anthroaquic Udifluvents: 관개수(灌漑水)의 영향(影響)을 받아 표토(表土)로부터 50cm이내(以內)에서 회색화작용(灰色化作用)을 받은 사양질 및 식양질계 충적토로 행곡통(杏谷統)이 이에 속(屬)한다. Fluventic Haplaquepts: 지하수위(地下水位)가 높아 토양은 전층이 회색화(灰色化)된 습답으로 유기물(有機物)의 함량(含量)은 토심(土深)이 깊어짐에 따라 불규칙적(不規則的)으로 감소(減少)되는 회색토(灰色土)로 백구 및 학성통등(鶴城統等)이 이에 속(屬)한다. Fuventic Thapto-Histic Haplaquepts: Fluventic Haplaquepts와 유사(類似)하나 토양단면내에 유기물층이 개재된 습답으로 공덕(孔德) 및 서탄통(西炭統)이 이에 속(屬)한다. Fluventlc Aeric Haplaquepts: Fluventic Haplaquepts보다 지하수위(地下水位)가 비교적(比較的) 낮으므로 토양배수가 약간 불량(不良)한 회색토(灰色土)로 만경(萬頃) 및 전북통등(全北統等)이 이에 속(屬)한다. Fluventic Thapto-Histic Aeric Hapldquepts: Fluventic Thapto-Histic Haplaquepts보다 지하수위(地下水位)가 비교적(比較的) 낮으므로 토양배수가 약간 불량(不良)한 회색토(灰色土)로 봉남통(鳳南統)이 이에 속(屬)한다. Fluventic Aeric Sulfic Haplaquepts: Fluventic Aeric Haplaquepts에 비(比)하여 토심(土深) 50~150cm 사이에 황색반문(黃色斑紋)(PH<4.0)인 유화물집적층이 있는 회색토(灰色土)로 등구통이 이에 속(屬)한다. Fluventic Sulfaquepts: 이들 토양은 주(主)로 강하류(江下流)에서 바다로 유입(流入)되는 지점(地点) 및 간석 소택지에 분포(分布)되며 표토(表土)에서 50cm이내(以內)에 유화물집적층이 있는 습답으로 봉림(鳳林) 및 해척통(海拓統)이 이에 속(屬)한다. Fluventic Aeric Sulfaquepts: Fluventic Sulfaquepts 보다 지하수위(地下水位)가 비교적(比較的) 깊으므로 토양 배수(排水)가 약간 불량(不良)한 회색토(灰色土)로 김해통(金海統)이 이에 속(屬)한다. Anthro aquic Fluvaquentic Eutrochrepts: 관개수(漑水)의 영향(影響)을 받아 표토(表土)로 부터 50cm이상(以上) 회색화(灰色化)되고 염기포화도가 높은(>60%) 토양이며 장유(長有) 및 칠곡통등(漆谷統等)이 이에 속(屬)한다. Anthro aquic Dystric Fluventic Eutrochrepts: Anthro aquic Fluvaquentic Eutrochrepts와 유사(類似)하나 회색화작용(灰色化作用)은 표토(表土)로부터 50cm이내(以內)에서만 나타나는 토양이며 월곡(月谷) 및 경산통등(慶山統等)이 이에 속(屬)한다. Anthro aquic Fluventic Dystrochrepts; Anthro aquic Dystric Fluventic Eutrochrepts에 비(比)하여 염기포화도가 낮은(<60%) 토양으로 고천(高川) 및 비곡통등(秘谷統等)이 이에 속(屬)한다. Anthre aquic Eutrandepts; 염기포화도가 높은 (>50%) 화산회토(火山灰土)로 대정통(大靜統)이 이에 속(屬)한다. Anthre aquic Hapludalfs; 관개수(灌漑水)의 영향(影響)을 받아 표토(表土)로부터 50cm 이내(以內)에서 회색화작용(灰色化作用)을 받은 적황색토(赤黃色土)로 화동(華東) 및 용수통등이 이에 속(屬)한다. Anthro aquic Aquic Hapludalfs; Anthro aquic Hapludalfs에 비(比)하여 회색화작용(灰色化作用)을 더 받은(표토(表土)에서 50cm이상(以上)) 적황색토(赤黃色土)로 덕평(德坪) 및 극락통등이 이에 속(屬)한다.

  • PDF