• Title/Summary/Keyword: high nitrogen steel

Search Result 140, Processing Time 0.032 seconds

I-V Characteristics of HTS Conductors with Joints (고온초전도 접합도체들의 I-V 특성에 관한 연구)

  • Sohn, Hyung-Hwan;Min, Chi-Hyun;Lee, Eon-Yong;Sim, Ki-Deok;Kim, Seok-Ho;Seong, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.679-680
    • /
    • 2006
  • Various different types of joining between High Tc superconducting(HTS) tapes were prepared and current-voltage(I-V) characteristic curves were investigated at 77 K, liquid nitrogen temperature. Two typos of HTS tapes wore used, one is no laminated tape(Sumitomo high strength type tape) and the other stainless steel laminated tape(AMSC(American Superconductors Inc.) 3ply tapes) Sample joints were lap-jointed with indium or solder. Joint resistances between Sumitomo tapes with 4-10 mm in length were estimated from I-V curves and in the range of $4-8n{\Omega}$ at 77 K. Joint resistances of AMSC tapes were in the range of $140-170n{\Omega}$, much higher than them of Sumitomo samples. The n-values of jointed HTS tapes were 50% of them with no joint. In AMSC tapes, indium is better than solder as the jointing material.

  • PDF

Effects of Grain Size on the Fatigue Properties in Cold-Expanded Austenitic HNSs

  • Shin, Jong-Ho;Kim, Young-Deak;Lee, Jong-Wook
    • Metals and materials international
    • /
    • v.24 no.6
    • /
    • pp.1412-1421
    • /
    • 2018
  • Cold-expanded austenitic high nitrogen steel (HNS) was subjected to investigate the effects of grain size on the stress-controlled high cycle fatigue (HCF) as well as the strain-controlled low cycle fatigue (LCF) properties. The austenitic HNSs with two different grain sizes (160 and $292{\mu}m$) were fabricated by the different hot forging strain. The fine-grained (FG) specimen exhibited longer LCF life and higher HCF limit than those of the coarse-grained (CG) specimen. Fatigue crack growth testing showed that crack propagation rate in the FG specimen was the same as that in the CG specimen, implying that crack propagation rate did not affect the discrepancy of LCF life and HCF limit between two cold-expanded HNSs. Therefore, it was estimated that superior LCF and HCF properties in the FG specimen resulted from the retardation of the fatigue crack initiation as compared with the CG specimen. Transmission electron microscopy showed that the effective grain size including twin boundaries are much finer in the FG specimen than that in the CG specimen, which can give favorable contributions to strengthening.

Analysis on the Dielectric Characteristics of Gaseous Nitrogen for Developing Eco-friendly High Voltage Apparatuses (친환경 고전압 전력기기 개발을 위한 GN2의 절연특성 분석)

  • Bang, Seungmin;Lee, Onyou;Kim, Junil;Kang, Jong O;Lee, Hongseok;Ko, Taekuk;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.356-360
    • /
    • 2014
  • The environmental pollution caused by green-house gases such as $SF_2$ has been becoming the main issue of industrial society. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions [1]. Therefore, a study on the dielectric characteristics of the $GN_2$ is important for designing a eco-friendly high voltage apparatuses. In this paper, to develop an electrically reliable, stable, and eco-friendly high voltage apparatus, the breakdown voltage and partial discharge inception voltage characteristics in $GN_2$ considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. Also, the dielectric characteristics of the $GN_2$ are analyzed by using a Finite Elements Method (FEM) according to various field utilization factors. The results are expected to be applicable to designing the high voltage apparatuses using $GN_2$ as an insulation gas.

Effects of different levels of crude protein and protease on nitrogen utilization, nutrient digestibility, and growth performance in growing pigs

  • Kim, Yong Ju;Kim, Tae Heon;Song, Min Ho;An, Ji Seon;Yun, Won;Lee, Ji Hwan;Oh, Han Jin;Lee, Jun Soeng;Kim, Gok Mi;Kim, Hyeun Bum;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • v.62 no.5
    • /
    • pp.659-667
    • /
    • 2020
  • This study was conducted to evaluate the effects of different levels of crude protein (CP) and protease on nitrogen (N) utilization, nutrient digestibility, and growth performance in growing pigs. A total of six crossbred ([Landrace × Yorkshire] × Duroc) barrows were individually accepted in 1.2 m × 0.7 m × 0.96 m stainless steel metabolism cages. The pigs (average initial body weight of 27.91 ± 1.84 kg) randomly assigned to six diets with six weeks (6 × 6 Latin square design). The experiment was carried out in an environment with a temperature of 23 ± 1.5℃, a relative humidity of 83 ± 2.3% and a wind speed of 0.25 ± 0.03 m/s. The dietary treatments were arranged in a 2 × 3 factorial design with two levels of CP (15.3% or 17.1%) and three levels of protease (0 ppm, 150 ppm, or 300 ppm). The average daily gain and gain to feed ratio (G:F) tended to increase (p = 0.074) with increasing amounts of protease. The low CP level diet reduced (p < 0.050) urinary and fecal N concentrations, the total N excretion in feces, and increased (p < 0.050) N retention. Different protease levels in the diet did not affect (p > 0.05) at N intake, but supplementation of the diets with 300 ppm protease decreased (p < 0.050) the N concentration in urine and feces and tended to increase (p = 0.061) the percentage of N retention retained of the total N intake. The dietary CP level did not affect (p > 0.050) the apparent total tract digestibility (ATTD) of dry matter, digestible energy (DE), and metabolic energy (ME), but diet supplementation with 300 ppm protease showed higher (p < 0.050) ATTD of DE and ME than in the protease-free diet. Therefore, a low protein diet with protease could improve the utilization of nitrogen, thereby reducing the negative effect of N excretion into the environment while maintaining or increasing growth performance compared to a high protein diet.

Mercury Research and Management in Korea (국내 수은 연구 동향 및 관리 현황)

  • Jurng, Jong-Soo;Shim, Shang-Gyoo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.2
    • /
    • pp.99-107
    • /
    • 2009
  • This paper reviews the current status of mercury research on exposure and contamination, mercury emissions, emission limits and control technologies, long-range transport and deposition research, and mercury management policy in Korea. According to a monitoring of the Ministry of Environment and the Ministry of Health and Welfare, blood mercury levels among Koreans are $5{\sim}8$ times higher than those of U.S. and Germany. The most dominant source of exposure to mercury is through dietary intake. Emissions of mercury from coal-fired power plants are estimated 8.93 ton/year in 2004. Emissions of mercury from other important sources, such as waste incineration, steel and cement manufacturing and non-ferrous metal smelting operations are to be further investigated. A study on long-range transport of mercury suggests that the dry deposition flux over the Yellow Sea was much greater than those for other oceans. As a whole, the amounts of wet depositions of nitrogen and sulfur were 1.9 and 1.5 times larger than the amounts of dry depositions in each species, respectively. Substantial influence from China caused by high emissions in East China and westerly wind was possibly suggested. However, the influence from nitrogen emission in Korea was also confirmed. Korean Government has already adopted stringent emission limits on mercury for incinerators and boilers in 2005. However, emission limits for coal-fired power plants and non-ferrous metal smelters are rather relaxed. As the above mentioned two sources can be two most important sources of mercury emissions, control strategy for those sources are to be considered.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

Removal of Nitrate-Nitrogen in Pickling Acid Wastewater from Stainless Steel Industry Using Electrodialysis and Ion Exchange Resin (전기투석과 이온교환수지를 이용한 스테인레스 산업의 산세폐수 내 질산성 질소의 제거)

  • Yun, Young-Ki;Park, Yeon-Jin;Oh, Sang-Hwa;Shin, Won-Sik;Choi, Sang-June;Ryu, Seung-Ki
    • Journal of Environmental Science International
    • /
    • v.18 no.6
    • /
    • pp.645-654
    • /
    • 2009
  • Lab-scale Electrodialysis(ED) system with different membranes combined with before or after pyroma process were carried out to remove nitrate from two pickling acid wastewater containing high concentrations of $NO_3\;^-$(${\approx}$150,000 mg/L) and F($({\approx}$ 160,000 mg/L) and some heavy metals(Fe, Ti, and Cr). The ED system before Pyroma process(Sample A) was not successful in $NO_3\;^-$ removal due to cation membrane fouling by the heavy metals, whereas, in the ED system after Pyroma process(Sample B), about 98% of nitrate was removed because of relatively low $NO_3\;^-$ concentration (about 30,000 mg/L) and no heavy metals. Mono-selective membranes(CIMS/ACS) in ED system have no selectivity for nitrate compared to divalent-selective membranes(CMX/AMX). The operation time for nitrate removal time decreased with increasing the applied voltage from 10V to 15V with no difference in the nitrate removal rate between both voltages. Nitrate adsorption of a strong-base anion exchange resin of $Cl\;^-$ type was also conducted. The Freundlich model($R^2$ > 0.996) was fitted better than Langmuir mode($R^2$ > 0.984) to the adsorption data. The maximum adsorption capacity ($Q^0$) was 492 mg/g for Sample A and 111 mg/g for Sample B due to the difference in initial nitrate concentrations between the two wastewater samples. In the regeneration of ion exchange resins, the nitrate removal rate in the pickling acid wastewater decreased as the adsorption step was repeated because certain amount of adsorbed $NO_3\;^-$ remained in the resins in spite of several desorption steps for regeneration. In conclusion, the optimum system configuration to treat pickling acid wastewater from stainless-steel industry is the multi-processes of the Pyroma-Electrodialysis-Ion exchange.

The preparation of ultra hard nitrogenated DLC film by $N_2^+$ implantation

  • Olofinjana, A.O.;Chen, Z.;Bell, J.M.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.165-166
    • /
    • 2002
  • Hydrogen free diamond like carbon (DLC) films were prepared on steel substrates by using a single ion beam in a configuration that allowed sputtering of a graphite target and at the same time allowed to impact the substrate at a grazing angle. The DLC films so prepared have improved properties with increased disorder and with modest hardness that is slightly higher than previously reported values. We have studied the effects of $N_2^+$ ions implantation on such films. It is found that the implantations of nitrogen ions into DLC films lead to chemical modifications that allowed N atoms to be incorporated into the carbon network to produce a nitrogenated DLC. Nano-indentation experiments indicated that the nitrogenated films have consistently higher hardnesses ranging from 30 to 45GPa, which represents a considerable increase in surface hardness, compared with non-nitrogenated precursor films. The investigations by XPS and Raman spectroscopy suggests that the $N_2^+$ implanted DLCs had undergone both chemical and structural modifications through the incorporation of N atoms and the increased ratio of $sp^3/sp^2$ type bonding. The observed high hardness was therefore attributable to these structural and chemical modifications. This result has implication for the preparation of super hard wear resistant films required for tribological functions in devices.

  • PDF

Atmospheric Micro Glow Plasma-jet Device (상압 마이크로 글로우 방전 분사 소자)

  • Kim, Kang-Il;Kim, Geun-Young;Hong, Yong-Cheol;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1533_1534
    • /
    • 2009
  • This paper presents an atmospheric micro glow plasma-jet device. The device consists of four components; a thin Ni anode, a porous alumina insulater, a stainless steel cathode and an aluminum case. The Ni anode is fabricated using micromachining technology. The anode has 10 holes, of which the hole diameter and the depth are $250{\mu}m$ and $60{\mu}m$, respectively. The discharge test is performed in nitrogen gas at atmospheric pressure for 20 kHz AC bias. The breakdown voltage is 3.5 kV at gas flow rate of 4 L/min and the the plasma-jet is blown out to ambient at 5.5 kV. In order to verify the characteristics of plasma, the current and the voltage of device are measured. The maximum temperature of plasma is $37^{\circ}C$. The plasma is well generated and stable at high voltage.

  • PDF

Characteristics of TiN Films by ion Beam Assisted Deposition (이온빔 보조 증착에 의한 TiN 박막의 특성)

  • Kim, Sang Hyun;Kim, Dae Hyeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.161-166
    • /
    • 2004
  • In this research, TiN films has been grown to the stainless steel substrate by ion beam assisted deposition. TiN film was grown to the nitrogen atmosphere of around $10^{-15}$ Torr with Arion bombardment. The chemical composition, color and adhesion of TiN films were examined as a variation of En(ion energy per atom). The N/Ti ratio increased linearly as the increase of En and saturated around 1.2 at high En. As a results, the bright golden color was obtained when En reached a certain value of Ecn. As a results, the N/Ti ratio is about 0.9.

  • PDF