• Title/Summary/Keyword: high heating

Search Result 3,196, Processing Time 0.03 seconds

A study on the Distance and Frequency Variable Characteristics of Flat Plate Induction Heating Element (평판 유도발열체의 거리·주파수 가변특성에 관한 연구)

  • Woo, Hyoung-Gyun;Shin, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.68-74
    • /
    • 2013
  • Induction-heated system is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. This technique is used high frequency inverter. By using high frequency inverter high frequency in the range of kHz can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. In this paper are discussed analysis of characteristics according to the each frequency and produced Flat plate induction heating system using 1.5kW-class half-bridge resonant inverter. In addition, operating characteristics of the system to changes in the distance between the coil and the heater, applications of system are also discussed.

Study on the Heat Generation Characteristics of the Carbon Heating Source with High Temperature (고온 카본발열체의 발열특성에 관한 연구)

  • Bae, K.Y.;Lee, K.S.;Shin, J.H.;Jeong, H.M.;Chung, H.S.;Chun, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.106-111
    • /
    • 2001
  • This paper is a study on the heat generation characteristics of the carbon heating source with high temperature. The main variables of this study are the input current and the amount of carbon heating source. As the results of the experiment in the waste rate of carbon heating source. The case of carbon heating source 300g was large than 500g. As the input current and the temperature are increased, the resistance values of carbon heating source were large. The Joule heat was represented the large value as the amount of heating source decrease with the input current. Finally, the heating source was represented the electrical steady state as the input current is increase.

  • PDF

Spalling Properties of Ring-Type Restrained Concrete by Heating Conditions (가열조건에 따른 링형 구속 콘크리트의 폭렬특성)

  • Hwang, Eui-Chul;Kim, Guy-Yong;Lee, Sang-Kyu;Son, Min-Jae;Baek, Jae-Wook;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.155-156
    • /
    • 2018
  • In this study, surface spalling and explosive spalling of ring-type ultra-high strength concrete under rapid heating and slow heating were investigated. In rapid heating, the internal temperature difference of the concrete is large, so that continuous surface spalling occurs. However, in slow heating, the difference in the internal temperature of the concrete is small, resulting in explosive spalling at a time. Since the heating condition has a great influence on the internal temperature of the concrete, it is necessary to consider the spalling of the concrete under various heating conditions.

  • PDF

Contributions of Heating and Forcing to the High-Latitude Lower Thermosphere: Dependence on the Interplanetary Magnetic Field

  • Kwak, Young-Sil;Richmond, Arthur;Ahn, Byung-Ho;Cho, Kyung-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.3
    • /
    • pp.205-212
    • /
    • 2010
  • To better understand the physical processes that maintain the high-latitude lower thermospheric dynamics, we have identified relative contributions of the momentum forcing and the heating to the high-latitude lower thermospheric winds depending on the interplanetary magnetic field (IMF) and altitude. For this study, we performed a term analysis of the potential vorticity equation for the high-latitude neutral wind field in the lower thermosphere during the southern summertime for different IMF conditions, with the aid of the National Center for Atmospheric Research Thermosphere-Ionosphere Electrodynamics General Circulation Model (NCAR-TIEGCM). Difference potential vorticity forcing and heating terms, obtained by subtracting values with zero IMF from those with non-zero IMF, are influenced by the IMF conditions. The difference forcing is more significant for strong IMF $B_y$ condition than for strong IMF $B_z$ condition. For negative or positive $B_y$ conditions, the difference forcings in the polar cap are larger by a factor of about 2 than those in the auroral region. The difference heating is the most significant for negative IMF $B_z$ condition, and the difference heatings in the auroral region are larger by a factor of about 1.5 than those in the polar cap region. The magnitudes of the difference forcing and heating decrease rapidly with descending altitudes. It is confirmed that the contribution of the forcing to the high-latitude lower thermospheric dynamics is stronger than the contribution of the heating to it. Especially, it is obvious that the contribution of the forcing to the dynamics is much larger in the polar cap region than in the auroral region and at higher altitude than at lower altitude. It is evident that when $B_z$ is negative condition the contribution of the forcing is the lowest and the contribution of the heating is the highest among the different IMF conditions.

Spalling of heated high performance concrete due to thermal and hygric gradients

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • v.4 no.1
    • /
    • pp.1-14
    • /
    • 2016
  • In this study, high performance concrete beams and prisms with high content of PFA were heated to various temperatures up to $450^{\circ}C$ at heating rates of $1^{\circ}C/min$, $3^{\circ}C/min$ and $10^{\circ}C/min$. The thermal gradient was found to increase first with the heating time until a peak value was reached and then decrease until the thermal equilibrium was reached, measured as $115^{\circ}C$, $240^{\circ}C$ and $268^{\circ}C$ for the three heating rates. Spalling occurred on some specimens when the heating temperature was over $400^{\circ}C$ for heating rates of $3^{\circ}C/min$ and $10^{\circ}C/min$. The hygric gradient was found to reach its maximum when the thermal gradient reached its peak. This study indicates that spalling of HPC could happen when the heating temperature was high enough, and both thermal and hygric gradients reached their maxima.

Characteristics of plasma sprayed composite YSZ/Ni-Cr resistant heating coatings (YSZ/Ni-Cr 저항 발열 복합용사피막의 특성)

  • 김병수;박경채;김태형;양병모
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.111-113
    • /
    • 2003
  • The existing heating unit is indirect-heating method that make use or the nichrome wire or halogen lamp. The indirect-heating method has the demerits of long warming time, high power consumption and many organization parts. In this study, the heating unit of direct-heating method manufactured as being the thermal spray coating of conductive heating material on the surface of heating unit in order to improve the demerits of indirect-heating method. And YSZ added Ni-20Cr that had moderate electrical resistivity was chosen of the conductive heating material.

  • PDF

An Experimental Study on the Mechanical Properties of High Strength of High Strength Concrete Subject to High Temperature Heating (고온가열을 받은 고강도 콘크리트의 역학적 특성에 관한 실험적 연구)

  • Lee, Tae-Gyu;Sin, Seung-Bong;Kim, Young-Sun;Lee, Seung-Hoon;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.9-12
    • /
    • 2007
  • Recently, research and development related to high strength concrete for the high rise and large scale reinforced concrete building has been actively promoted in worldwide by national and private research project. But, it is reported that violent explosive explosion would be happened when it was exposed in fire. In the existed study, a explosion in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement paste and aggregate, and causes crack by thermal stress. In case of the Europe, Japan and America, they have studied the explosion for a long time. However it would hardly study the explosion in domestic, So it is needed base on mechanical properties of fire deterioration in high strength concrete. Therefore, this study is intend as an mechanical properties of specimen to high heating by heating and load test machine and $700^{\circ}C$. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF

Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics) (PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

Quality Characteristics of Cod Stock with Different Extraction Time - Using High Pressure Extraction Time - (추출 시간을 달리하여 제조한 대구 육수의 품질 특성 - 고압 가열 추출 방식으로 -)

  • Kim, Dong-Seok;Lee, Sang-Hwa;Choi, Wu-Kuk;Shin, Kyung-Eun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.23 no.2
    • /
    • pp.203-210
    • /
    • 2013
  • In this study, cod bone were used as the main ingredient of a stock that can be eaten with Korean dried noodles. The stock was produced with heating for 30, 40, 50, 60, or 70 minutes using high-pressure extraction methods. Moisture content, chromaticity, pH, sugar content, salinity, mineral contents, quantitative analysis, and overall acceptance were studied to determine the optimal heating time. In our result, S1 the showed highest water contents 98.10%, while S5 showed the lowest moisture content (97.47%). There were no significant difference in pH between samples, while salinity and sugar content increased with increases in heating time. In terms of mineral contents, sodium and potassium showed proportional difference with increases in heating time, however, magnesium, calcium, and iron did not change. The results from a quantitative analysis test showed that transparency, fishy smell, delicate flavor, savory flavor, salt taste, and umami taste became stronger with increases in heating time increase. From the above results, the overall taste of the stock increases with increases in high-pressure heating time. Specifically, S4 high-pressure heating scored the highest on appearance, flavor, taste, after-taste, and overall acceptance. Thus, 60 minutes of high-pressure heating time is most desirable when producing stock with cod bones as a main ingredient.

A Study on the Induction Heating for Aluminum Sheet Using High-Frequency Resonant Inverter) (고주파 공진형 인버터를 이용한 알루미늄 박판가열에 관한 연구)

  • Shin, Dae-Chul;Kim, Sung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.90-94
    • /
    • 2004
  • In this treatise, The "Induction-Heating" and "The Skin Effect" which resulted from the High-Frequency using the High-Frequency Resonant Inverter are showed by this paper. It would research into "The Electro-magnetic Induction" and "The skin Effect" with an aluminum which is the typical paramagenetic metal. Ultimately, it was focused on the possibility of the heating for an aluminum sheet and draw up its practical use-plan.