1 |
Ali, F.A. (2002), "Is high performance concrete more susceptible to explosive spalling than normal strength concrete in fire?", Fire Mater., 26(3), 127-130.
DOI
|
2 |
Ali, F.A., O'Connor, D. and Abu-Tair, A. (2001), "Explosive spalling of high-strength concrete columns in fire", Mag. Concrete Res., 53(3), 197-204.
DOI
|
3 |
Arita, F., Harada, K. and Miyamoto, K. (2002), "Thermal spalling of high-performance concrete during fire", Second International Workshop on Structures in Fire, Christchurch, New Zealand, 253-261.
|
4 |
Bentz, D. (2000), "Fibers, percolation, and spalling of high-performance concrete", ACI Mater. J., 97(3), 351-359.
|
5 |
Castillo, C. and Durrani, A.J. (1990), "Effect of transient high temperature on high-strength-concrete", ACI Mater. J., 87(1), 47-53.
|
6 |
Dong, X., Ding, Y. and Wang, T. (2008), "Spalling and mechanical properties of fiber reinforced high-performance concrete subjected to fire", J. Wuhan University of Tech.-Mater. Sci. Ed., 743-749.
|
7 |
Dwaikat, M.B. and Kodur, V.K.R. (2008), "A numerical approach for modeling the fire induced restraint effects in reinforced concrete beams", Fire Safety J., 43(4), 291-307.
DOI
|
8 |
Dwaikat, M.B. and Kodur, V.K.R. (2009a), "Hydrothermal model for predicting fire-induced spalling in concrete structural systems", Fire Safety J., 44(3), 425-434.
DOI
|
9 |
Dwaikat, M.B. and Kodur, V.K.R. (2009b), "Fire induced spalling in high strength concrete beams", Fire Tech., 46(1), 251-274.
DOI
|
10 |
Hertz, K.D. (2003), "Limits for spalling of fire-exposure concrete", Fire Safety J., 38(2), 103-116.
DOI
|
11 |
Hertz, K.D. and Sorensen, L.S. (2005), "Test method for spalling of fire exposure concrete", Fire Safety J., 40(5), 466-476.
DOI
|
12 |
Kanema, M., Pliya, P., Noumowe, A. and Gallias, J. (2011), "Spalling, thermal, and hydrous behavior of ordinary and high-strength concrete subjected to elevated temperature", J. Mater. Civil Eng., 23(7), 921-930.
DOI
|
13 |
Ko, J., Ryu, D. and Noguchi, T. (2011), "The spalling mechanism of high strength concrete under fire", Mag. Concrete Res., 63(5), 357-370.
DOI
|
14 |
Kodur, V.K.R. (1998), "Fire performance of high-strength concrete structural members", Can. J. Civil Eng., 25(6), 975-981.
DOI
|
15 |
Kodur, V.K.R. (2000), "Spalling in high-strength concrete exposed to fire: concerns, causes, critical parameters and cures", Adv. Tech. Struct. Eng., Ed by Mohamed Elgaaly P.E., 1-9.
|
16 |
Kodur, V.K.R. and Phan, L. (2007), "Critical factors governing the fire performance of high strength concrete systems", Fire Safety J., 42(6), 482-488.
DOI
|
17 |
Morita, T., Nishida, A. and Yamazaki, N. (1999), "An experimental study on spalling of high strength concrete elements under fire attack", Fire Safety Science-the Proceeding of the Sixth International Symposium, July 5-9, 1999, Poitiers, France, 855-866.
|
18 |
Ozbolt, J., Kozar, I., Eligehausen, R. and Periskic, G. (2005), "Three-dimensional FE analysis of headed stud anchors exposed to fire", Comput. Concrete, 2(4), 249-266.
DOI
|
19 |
Savov, K., Lackner, R. and Mang, H.A. (2005), "Stability assessment of shallow tunnels subjected to fire load", Fire Safety J., 40(8), 745-763.
DOI
|
20 |
Sullivan, P.J.E. (2001), "Deterioration and spalling of high strength concrete under fire", Offshore Technology Report 2001/074, City University, London.
|
21 |
Zhang, B. and Bicanic, N. (2006), "Fracture energy of high-performance concrete at high temperatures up to : the effects of heating temperatures and testing conditions (hot and cold)", Mag. Concrete Res., 58(5), 277-288.
DOI
|
22 |
Zeimla, M., Lacknera, R., Pesaventoc, F. and Schrefler, B.A. (2008), "Thermo-hydro-chemical couplings considered in safety assessment of shallow tunnels subjected to fire load", Fire Safety J., 43(2), 83-95.
DOI
|
23 |
Zhang, B. (2011), "Effects of moisture evaporation (weight loss) on fracture properties of high performance concrete subjected to high temperatures", Fire Safety J., 46(8), 543-549.
DOI
|
24 |
Zhang, B. and Bicanic, N. (2002a), "Residual fracture toughness of normal-and high-strength gravel concrete after heating to ", ACI Mater. J., 99(3), 217-226.
|
25 |
Zhang, B., Bicanic, N., Pearce, C.J. and Balabanic, G. (2000), "Residual fracture properties of normal-and high-strength concrete subject to elevated temperatures", Mag. Concrete Res., 52(2), 123-136.
DOI
|
26 |
Zhang, B., Bicanic, N., Pearce, C.J. and Phillips, D.V. (2002b), "Relationship between brittleness and moisture loss of concrete exposed to high temperatures", Cement Concrete Res., 32(3), 363-371.
DOI
|
27 |
Zhang, B., Cullen, M. and Kilpatrick, T. (2013), "Fracture toughness of high performance concrete subjected to elevated temperatures: the effects of heating temperatures and testing conditions (hot and cold)", The 2013 International Conference on Computational Technologies in Concrete Structures, 8-12 September 2013, Jeju, Korea.
|
28 |
Zhang, H.L. and Davie, C.T. (2013), "A numerical investigation of influence of pore pressures and thermally induced stresses for spalling of concrete exposed to elevated temperatures", Fire Safety J., 59, 102-110.
DOI
|
29 |
Zheng,W.Z., Hou, X.M., Shi, D.S. and Xu, M.X. (2010), "Experimental study on concrete spalling in prestressed slabs subjected to fire", Fire Safety J., 45(5), 283-297.
DOI
|
30 |
Zhao, J., Zheng, J.J., and Peng, G.F. (2011), "Fire spalling modeling of high performance concrete", Appl. Mech. Mater., 52-54, 378-383.
DOI
|