• Title/Summary/Keyword: high frequency monitoring

Search Result 547, Processing Time 0.202 seconds

The Construction of the Fishing-vessel Monitoring System and the Protocol Analysis for the Calling of Location Requirement Using VHF-DSC (VHF-DSC 위치요청 프로토콜 분석과 어선관제시스템 구축)

  • Kim, Jeong-nyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.929-932
    • /
    • 2013
  • In preperation for the compulsory installation of VHF(Very High Frequency) wireless equipment and fishing vessel automatic identification system according to the revision of "The Ships Safety Act" and "Fishing Vessel act", Fishery Information & Communication Department of National Federation of Fisheries Cooperatives is building VHF communication network and automatic identification system for fishing vessel monitoring. This study suggests the protocol analysis for the calling of location requirement using DSC(Digital Selective Calling) function and show best way for fishing vessel automatic identification system. Also, it suggest way to realize fishing vessel monitoring system.

  • PDF

The Construction of the Vessel Monitoring System and the Protocol Analysis for the Calling of Location Requirement Using VHF-DSC (VHF-DSC 위치요청 프로토콜 분석과 선박관제시스템 구축)

  • Kim, Jeong-Nyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2800-2805
    • /
    • 2013
  • In preperation for the compulsory installation of VHF(Very High Frequency) wireless equipment and fishing vessel automatic identification system according to the revision of "The Ships Safety Act" and "Fishing Vessel act", Fishery Information & Communication Department of National Federation of Fisheries Cooperatives is building VHF communication network and automatic identification system for fishing vessel monitoring. This study suggests the protocol analysis for the calling of location requirement using DSC(Digital Selective Calling) function and show best way for fishing vessel automatic identification system. Also, it suggest way to realize fishing vessel monitoring system.

Fault Detection of Rolling Element Bearing for Low Speed Machine Using Wiener Filter and Shock Pulse Counting (위너 필터와 충격 펄스 카운팅을 이용한 저속 기계용 구름 베어링의 결함 검출)

  • Park, Sung-Taek;Weon, Jong-Il;Park, Sung Bum;Woo, Heung-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1227-1236
    • /
    • 2012
  • The low speed machinery faults are usually caused by the bearing failure of the rolling elements. As the life time of the bearing is limited, the condition monitoring of bearing is very important to maintain the continuous operation without failures. A few monitoring techniques using time domain, frequency domain and fuzzy neural network vibration analysis are introduced to detect and diagnose the faults of the low speed machinery. This paper presents a method of fault detection for the rolling element bearing in the low speed machinery using the Wiener filtering and shock pulse counting techniques. Wiener filter is used for noise cancellation and it clearly makes the shock pulse emerge from the time signal with the high level of noise. The shock pulse counting is used to determine the various faults obviously from the shock signal with transient pulses not related with the bearing fault. Machine fault simulator is used for the experimental measurement in order to verify this technique is the powerful tool for the low speed machine compared with the frequency analysis. The test results show that the method proposed is very effective parameter even for the signal with high contaminated noise, speed variation and very low energy. The presented method shows the optimal tool for the condition monitoring purpose to detect the various bearing fault with high accuracy.

Identification of High Frequency Peakers with long-term monitoring observation at 22 and 43 GHz

  • Jeong, Yongjin;Sohn, Bong Won;Chung, Aeree
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.68.2-68.2
    • /
    • 2014
  • High Frequency Peakers (HFPs) are radio-loud Active Galactic Nuclei (AGN), which are regarded as being in the earliest evolutionary phase (102-103 years) of radio galaxies. They are expected to be small in size (< ~1 kpc) compared to their host galaxies (~a few 10s kpc), and have convex spectra, which are peaking at high radio frequency (> 5 GHz). Their size and spectral shape are the most obvious supporting evidence of extremely young ages. HFPs are therefore ideal targets to probe the earliest stage of radio sources. To date however, the young radio source classification has been relying mainly on the spectral shape which usually does not cover high enough frequencies where the true peak flux is located. Hence HFPs are often confused with blazars which may show a similar spectral shape and apparent compactness but are a somewhat evolved form of AGNs. Therefore, we have been challenging to identify HFPs among the sample of 19 candidates using the Korean VLBI Network (KVN) which enables us to extend the radio spectrum baseline up to 22 and 43 GHz. These are higher than the frequencies used in most previous studies of HFPs, allowing us to select genuine HFPs. By long-term monitoring of 18 epochs, we have also inspected the variability of the sample to select out blazars which are highly variable yet with a similar radio spectrum. In this work, we present the light curves and spectral properties of the HFP candidates. We discuss the results of our re-identification of HFPs.

  • PDF

Condition Monitoring in Gear System Using Spike Wavelet Transform (스파이크 웨이블렛 변환을 이용한 기어 시스템의 건전성 감시)

  • 이상권;심장선
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.21-27
    • /
    • 2001
  • Impulsive sound and vibration signals in gear system are often associated with their faults. Thus these impulsive sound and vibration signals can be used as indicators in condition monitoring of gear system. The traditional continuous wavelet transform has been used for detection of impulsive signals. However, it is often difficult for the continuous wavelet transform to identify spikes at high frequency and meshing frequencies at low frequency simultaneously since the continuous wavelet transform is to apply the linear scaling (a-dilation) to the mother wavelet. In this paper, the spike wavelet transform is developed to extract these impulsive sound and vibration signals. Since the spike wavelet transform is to apply the non-linear scaling, it has better time resolution at high frequency and frequency resolution at low frequency than that of the continuous wavelet transform respectively. The spike wavelet transform can be, therefore, used to detect fault position clearly without the loss of information for the damage of a gear system. The spike wavelet transform is successfully is applied to detection of the gear fault with tip breakage.

  • PDF

Current Status of Parents' Monitoring of and Level of Trust in School Lunch Programs (학부모의 학교급식 모니터링 현황 및 학교급식에 대한 신뢰도)

  • Hur, Boyoung;Choi, Injoo;Kim, Meeyoung;Kwon, Jinwook;Lee, Jiyoung;Yoon, Jihyun
    • Korean Journal of Community Nutrition
    • /
    • v.22 no.5
    • /
    • pp.401-412
    • /
    • 2017
  • Objectives: The purpose of this study was to investigate the current status of parents' monitoring of school lunch programs and to examine the relationship of parents' school lunch monitoring with their level of trust in school lunch programs. Methods: During November 2016, a web survey was conducted with 1,283 parents who had participated in monitoring of school lunch programs. A total of 621 parents completed the questionnaires (48.4% response rate) and the responses from 442 parents were analyzed (34.5% analysis rate) for elementary (n=196) and middle/high school parents (n=246), respectively. Results: Both the elementary and middle/high school parents most wanted to participate in monitoring 1~2 times per month, which was less frequent than their current practice. They showed the highest experience rate in 'food sanitation' area in both the prior training and actual practice of school lunch monitoring. They most responded 'increasing trust in school lunch programs' as a merit and 'lack of parents participating in monitoring' as a problem of school lunch monitoring. The average levels of trust did not differ between elementary and middle/high school parents. Multiple regression analyses showed that elementary school parents' level of satisfaction in the monitored school lunch programs was positively associated with the parents' level of trust in general school lunch programs. Monitoring frequency and parents' age, in addition to level of satisfaction in the monitored school lunch program, were associated with level of trust in general school lunch programs among middle/high school parents. Conclusions: There was room for change in parents' school lunch monitoring programs to meet parents' needs better. Well-managed school lunch monitoring programs contributing to parents' satisfaction with school lunch programs could increase parents' level of trust in school lunch programs.

Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system (UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

A Study on Health Monitoring of a Refrigerator Compressor Based on Higher Order Time-Frequency Analysis and Artificial Neural Network (고차 시간-주파수 해석과 신경망 회로를 이용한 냉장고 압축기의 건전성 연구)

  • Shin, Tae-Jin;Lee, Sang-Kwon;Jang, Ji Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.12
    • /
    • pp.1313-1320
    • /
    • 2012
  • Condition monitoring of the reciprocating compressor is important task. As a traditional method, health monitoring system of refrigerator depends on decision of a skilled person based on his experience. However, the skilled person cannot monitor all the compressors completely. If a sampled compressor is faulty, thousands of compressors manufactured at that place are regarded as faulty compressors. Therefore it is necessary to monitor all compressors in the production line. In the paper real time health monitoring system is developed based on high order time frequency method and artificial neural network. The system is installed in the mass production line. The result of the application has been very successful, and currently the system is working very well on the production line.

Simultaneous monitoring of motion ECG of two subjects using Bluetooth Piconet and baseline drift

  • Dave, Tejal;Pandya, Utpal
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.365-371
    • /
    • 2018
  • Uninterrupted monitoring of multiple subjects is required for mass causality events, in hospital environment or for sports by medical technicians or physicians. Movement of subjects under monitoring requires such system to be wireless, sometimes demands multiple transmitters and a receiver as a base station and monitored parameter must not be corrupted by any noise before further diagnosis. A Bluetooth Piconet network is visualized, where each subject carries a Bluetooth transmitter module that acquires vital sign continuously and relays to Bluetooth enabled device where, further signal processing is done. In this paper, a wireless network is realized to capture ECG of two subjects performing different activities like cycling, jogging, staircase climbing at 100 Hz frequency using prototyped Bluetooth module. The paper demonstrates removal of baseline drift using Fast Fourier Transform and Inverse Fast Fourier Transform and removal of high frequency noise using moving average and S-Golay algorithm. Experimental results highlight the efficacy of the proposed work to monitor any vital sign parameters of multiple subjects simultaneously. The importance of removing baseline drift before high frequency noise removal is shown using experimental results. It is possible to use Bluetooth Piconet frame work to capture ECG simultaneously for more than two subjects. For the applications where there will be larger body movement, baseline drift removal is a major concern and hence along with wireless transmission issues, baseline drift removal before high frequency noise removal is necessary for further feature extraction.

Blast vibration of a large-span high-speed railway tunnel based on microseismic monitoring

  • Li, Ao;Fang, Qian;Zhang, Dingli;Luo, Jiwei;Hong, Xuefei
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.561-569
    • /
    • 2018
  • Ground vibration is one of the most undesirable effects induced by blast operation in mountain tunnels, which could cause negative impacts on the residents living nearby and adjacent structures. The ground vibration effects can be well represented by peak particle velocity (PPV) and corner frequency ($f_c$) on the ground. In this research, the PPV and the corner frequency of the mountain surface above the large-span tunnel of the new Badaling tunnel are observed by using the microseismic monitoring technique. A total of 53 sets of monitoring results caused by the blast inside tunnel are recorded. It is found that the measured values of PPV are lower than the allowable value. The measured values of corner frequency are greater than the natural frequencies of the Great Wall, which will not produce resonant vibration of the Great Wall. The vibration effects of associated parameters on the PPV and corner frequency which include blast charge, rock mass condition, and distance from the blast point to mountain surface, are studied by regression analysis. Empirical formulas are proposed to predict the PPV and the corner frequency of the Great Wall and surface structures due to blast, which can be used to determine the suitable blast charge inside the tunnel.