• Title/Summary/Keyword: high ductility

Search Result 969, Processing Time 0.027 seconds

Seismic Details of Reinforced Concrete Structures of Limited Ductility in New Zealand Standard (뉴질랜드 기준에서의 제한된 연성의 RC 구조물 내진 상세설계)

  • 이한선;유은진;우성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.229-234
    • /
    • 2000
  • As the level of earthquake intensity in Korea is considered to be moderate, some structures or structural elements may be subjected to the reduced ductility demand, in contrast to the structures in high seismicity, due to the large inherent strength induced by gravity loads. New Zealand Standard(NZS) deals with there structures within the category of structures of limited ductility. This paper briefly reviews the applicability of the code, regarding limited ductility, for frame strucures which are commonly used as the office building structural system. The difference of the loading condition is considered. Details of the plastic hinge region are compared between NZS and Korean standard.

  • PDF

Ductility Evaluations of Internally Confined Hollow R.C Piers (내부 구속 중공 R.C 교각의 연성도 평가)

  • Han, Taek-Hee;Cho, In-Seuck;Kang, Young-Jong;Lee, Myeong-Sub
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.353-360
    • /
    • 2005
  • When the weight if a concrete member makes problems, or when the cost of the concrete is relatively high, it may be economical to use a hollow concrete member. But a hollow R.C Pier may have poor ductility because of the brittle failure at the inner face of the hollow R.C Pier. This brittle failure results from the absence of the confinement at the inner face of the hollow R.C Pier. To avoid this brittle failure an internally confined hollow R.C Pier was developed. Test results show that the energy ductility ratio of a internally confined hollow R.C Pier have a superior energy ductility ratio to a general hollow R.C Pier.

  • PDF

Earthquake-Resistance of Slender Shear Wall with No Boundary Confinement (단부 횡보강이 없는 세장한 전단벽의 내진성능)

  • 박홍근;강수민;조봉호;홍성걸
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.5
    • /
    • pp.47-57
    • /
    • 2000
  • Experimental and numerical studies were done to investigate seismic performance of slender shear walls with no boundary confinement that are principal structural members of high0rise bearing wall buildings. 1/3 scale specimens that model the plastic region of long slender shear walls subjected to combined axial load and bending moment were tested to investigate strength, ductility, capacity of energy dissipation, and strain distribution, The experimental results show that the slender shear walls fail due to early crushing in the compressive boundary, and then have very low ductility. The measured maximum compressive strain is 0.0021, much less than 0.004 being commonly used for estimation of ductility. This result indicates that the maximum compressive strain is not a fixed value but is affected by moment gradient along the shear wall height and distance from the neutral axis to the extreme compressive fiber.

RESEARCH OF WELDING EFFECT ON STRUCTURAL INTEGRITY AT HIGH TEMPERATURE

  • Tu, Shan-Tung;Yoon, Kee-Bong
    • Proceedings of the KWS Conference
    • /
    • 1998.10a
    • /
    • pp.11-24
    • /
    • 1998
  • The invention of fusion wilding technology has brought on a revolutionary change in manufacturing industry which enables the construction of large scale high temperature plants in chemical, petrochemical and power generation industries. However, among the failure cases of high temperature components, premature failures of weldments have taken a large percentage that indicates the detrimental effect of welding on structural integrity. The accurate prediction of the high temperature behaviour of welded components is thus becoming increasingly important in order to realise an optimised design and maintenance of a plant life. In the present paper, recent research activities on high temperature behaviour of welded structures are briefly summarised. A local deformation measuring technique is proposed to determine the creep properties of weldment constituents. A damage mechanics approach is introduced to study the life reduction and ductility reduction due to the presence of a weld in high temperature structures. Finally, the high temperature creep crack growth in weldments is discussed.

  • PDF

Seismic response modification factors for stiffness degrading soil-structure systems

  • Ganjavi, Behnoud;Bararnia, Majid;Hajirasouliha, Iman
    • Structural Engineering and Mechanics
    • /
    • v.68 no.2
    • /
    • pp.159-170
    • /
    • 2018
  • This paper aims to develop response modification factors for stiffness degrading structures by incorporating soil-structure interaction effects. A comprehensive parametric study is conducted to investigate the effects of key SSI parameters, natural period of vibration, ductility demand and hysteretic behavior on the response modification factor of soil-structure systems. The nonlinear dynamic response of 6300 soil-structure systems are studied under two ensembles of accelograms including 20 recorded and 7 synthetic ground motions. It is concluded that neglecting the stiffness degradation of structures can results in up to 22% underestimation of inelastic strength demands in soil-structure systems, leading to an unexpected high level of ductility demand in the structures located on soft soil. Nonlinear regression analyses are then performed to derive a simplified expression for estimating ductility-dependent response modification factors for stiffness degrading soil-structure systems. The adequacy of the proposed expression is investigated through sensitivity analyses on nonlinear soil-structure systems under seven synthetic spectrum compatible earthquake ground motions. A good agreement is observed between the results of the predicted and the target ductility demands, demonstrating the adequacy of the expression proposed in this study to estimate the inelastic demands of SSI systems with stiffness degrading structures. It is observed that the maximum differences between the target and average target ductility demands was 15%, which is considered acceptable for practical design purposes.

Assessment of Ductility and Plastic Hinge Region of Reinforced Concrete Multi-Column Bent (2주형 다주교각의 연성도 및 소성힌지 영역에 관한 연구)

  • Byun, Soon-Joo;Im, Jung-Soon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.3 s.22
    • /
    • pp.37-45
    • /
    • 2006
  • In this study, displacement ductility capacity and plastic hinge regions of reinforced concrete multi-column bent with different transverse reinforcement ratio are investigated. The ductility increases remarkably as transverse reinforcement ratio increase and the multi-column bent loaded along transverse direction is more ductile. The plastic hinge length for special detailing requirements of transverse reinforcement is estimated. For high target ductility, plastic hinge length for confinement should be extended with increased transverse reinforcement ratio. The plastic hinge length of multi-column bent loaded along transverse direction is shorter than that along longitudinal direction, because of the different moment distribution.

An Experimental Study on Flexural Behavior of Steel Fiber Reinforced Ultra High Performance Concrete (강섬유로 보강된 초고성능 콘크리트의 휨 거동에 대한 실험 연구)

  • Yang, In-Hwan;Joh, Chang-Bin;Kang, Su-Tae;Kim, Byung-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.737-744
    • /
    • 2009
  • In this study, the flexural behavior of steel fiber reinforced ultra high performance concrete (UHPC) was investigated. It presents experimental results of steel fiber reinforced UHPC with steel fiber content of 2% by volume and steel reinforcement ratio of less than 0.02. This study aims at providing more information about UHPC beams in bending in order to establish a reasonable prediction model for flexural resistance and deflection in structural code in the future. The experimental results show that UHPC is in favor of cracking behavior and ductility of beams, and that the ductility indices range from 6.29 to 10.44, which means high ductility of UHPC. Also, the flexural rigidity of beam whose cast is begun from end of beam is larger than that of beam whose cast is begun from midspan of beam. This result represents that the flexural rigidity is affected by the placing method of UHPC.

Structural Behavior of Hybrid Steel Fiber-Reinforced Ultra High Performance Concrete Beams Subjected to Bending (휨을 받는 하이브리드 강섬유 보강 초고성능 콘크리트 보의 구조 거동)

  • Yang, In-Hwan;Kim, Kyoung-Chul;Joh, Chang-Bin
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.771-778
    • /
    • 2014
  • This paper concerns the flexural behavior of hybrid steel fiber-reinforced ultra high performance concrete (UHPC) beams. It presents experimental research results of hybrid steel fiber-reinforced UHPC with steel fiber content of 1.5% by volume and steel reinforcement ratio of less than 0.02. This study aims at providing realistic information about UHPC beams in bending in order to establish a reasonable prediction model for flexural resistance in structural code in the future. The experimental results show that hybrid steel fiber-reinforced UHPC is in favor of cracking resistance and ductility of beams. The ductility indices range through 9.2 to 15.2, which means high ductility of UHPC. Also, the flexural capacity of beam which contains stirrups in pure bending zone is similar to that of beam which does not contain stirrups in pure bending zone. This result represents that the flexural capacity is not affected by the presence of stirrups whose spacing is 150 mm in bending zone.

Characteristics of Dissimilar CO2 Laser Welding for High Mn Steel and Low Carbon Steel (고Mn강과 저탄소강의 CO2 레이저 이종용접 특성)

  • Jeong, Bo-Young;Han, Tae-Kyo
    • Journal of Welding and Joining
    • /
    • v.28 no.3
    • /
    • pp.36-41
    • /
    • 2010
  • High Mn steel has been developed for automotive applications since the steel has an excellent combination of strength and ductility. However, from the viewpoint of welding, high Mn steel has a few problems related to its chemical composition. This paper describes characteristics of dissimilar $CO_2$ laser welding for expanding application of high Mn steel. From this work it was cleared that dissimilar laser welded joint between high Mn steel and carbon steel had poor formability due to the formation of martensite within weld metal. In order to improve ductility of welded joint, the method of controlling the dilution ratio of high Mn steel was suggested.

Ductility of High-Strength Concrete Columns with High-Strength Lateral Ties (고강도 띠철근으로 구속된 고강도 콘크리트 기둥의 연성)

  • 문호권;이영호;양근혁;정헌수
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.261-267
    • /
    • 2001
  • The objective of this experimental study is to find the allowable level of axial load to give the proper flexural ductility according to the yield strength of lateral ties, and the distribution and amount of longitudinal bars used in confined high-strength concrete columns. Twelve concrete columns with a 20 cm square section and 80 cm high were tested under hi-axial loads. It was observed that the ductility tends to be improved at the axial loads not less than 0.4f$\_$ck/A$\_$g/. The utilization of high-strength ties in accordance with the ACI 318-99 can cause the brittle failure due to the wide tie spacing. Under the high level of axial loads not less than 0.4f$\_$ck/A$\_$g/. it is necessary for the buckling prevention of the longitudinal bars and the proper ductility improvement to use the high-strength ties with the consideration of the volumetric ratio and confinement type of the lateral ties, and the distribution of the longitudinal bars.