Ductility Evaluations of Internally Confined Hollow R.C Piers

내부 구속 중공 R.C 교각의 연성도 평가

  • 한택희 (고려대학교 사회환경시스템공학과) ;
  • 조인석 (고려대학교 사회환경시스템공학과) ;
  • 강영종 (고려대학교 사회환경시스템공학과) ;
  • 이명섭 (삼성물산 건설부문)
  • Published : 2005.03.18

Abstract

When the weight if a concrete member makes problems, or when the cost of the concrete is relatively high, it may be economical to use a hollow concrete member. But a hollow R.C Pier may have poor ductility because of the brittle failure at the inner face of the hollow R.C Pier. This brittle failure results from the absence of the confinement at the inner face of the hollow R.C Pier. To avoid this brittle failure an internally confined hollow R.C Pier was developed. Test results show that the energy ductility ratio of a internally confined hollow R.C Pier have a superior energy ductility ratio to a general hollow R.C Pier.

Keywords