• 제목/요약/키워드: high dose rate

검색결과 878건 처리시간 0.028초

갑상선 악성종양에서 갑상선 전절제술 후 방사성 요오드 치료의 효과 (High Dose Therapy of Radioactive Iodine for Thyroid Ablation in Thyroid Carcinoma)

  • 안희철;강성준;홍인수
    • 대한두경부종양학회지
    • /
    • 제14권1호
    • /
    • pp.61-69
    • /
    • 1998
  • Objectives: The response rate of the radioactive iodine(RI) therapy with low dose was variable. Only a few studies reported the response and complication rate with high dose. The goal of this study was to access the ablation and complication rate after high dose of RI therapy (more than 100mCi) and to evaluate the factors affect the results. Material and Methods: During a period of 12 years, 225 patients received high dose of RI from 100 to 200mCi depending on the RI uptake in the whole body after total thyroidectomy. 100mCi of RI was given to 123 patients for ablation who showed the uptake only in the thyroid bed. 150mCi was given to another 84 patients for ablation who had uptake confined to the neck. The other 21 patients took more than 200mCi of RI because the whole body scan showed distant metastasis. Among these patients, the ablation and the complication rate was investigated. Results: Elevated level of the serum thyroglobulin(Tg) decreased less than 5ng/ml after RI therapy in all patients except two in the first group. The second group showed reduction of the serum Tg in 93%. Eighteen of the 21 patients in the third group are still alive after RI therapy. There were no fatal complications after high dose RI therapy and most of the complications were minimal and transient. The complication rate was not related with the dose of RI, age, sex, DNA flowcytometry, serum thyroglobulin level and the extent of node dissection. Conclusion: We concluded that RI therapy with high dose was very effective for thyroid ablation after operation and it also showed excellent results with minimal complications for treatment of metastatic lesions.

  • PDF

고 선량 감마선 조사에 따른 고휘도 LED의 가시광 무선 데이터 전송 (VLC Wireless Data Transmission of High Luminance LED Irradiated by the High Dose-Rate Gamma-Ray)

  • 조재완;최영수;홍석붕
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.996-1000
    • /
    • 2010
  • In order to apply VLC (visible light communication) in harsh environment of nuclear power plant in-containment building, the high luminance LEDs, which are key components of the VLC system, have been gamma irradiated at the dose rate of 4 kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced coloration effect in the high luminance LED bulb made of acryl or plastic material was observed. In the VLC wireless data transmission experiment using the high luminance LEDs irradiated by high dose rate gamma-ray, the radiation induced coloration effect of the high luminance LED bulb extended the communication distance compared to non-irradiated LEDs.

고선량율 근접치료기의 선원교정과 치료실주변 방사선량 측정 (Calibration and Radiation Survey of High Dose Rate Remote Afterloading System)

  • 이정옥;강정구;문성록
    • Radiation Oncology Journal
    • /
    • 제13권1호
    • /
    • pp.101-104
    • /
    • 1995
  • High Dose Rate Remote Afterloading system was installed at Wonkwang University Hospital in January 1994. In this report, the calibration of a Gammamed 12-i High Dose Rate Remote Afterloading system and the radiation survey around the facility after design and construct a shieding room are discussed. The radiation survey of the facility indicates that the use of ordinary concrete shielding of existing room will provide adequate shielding. Also, the methodologies for performing source calibration are presented.

  • PDF

원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사 (Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.55-64
    • /
    • 1998
  • 고선량률 원격 강내조사 선원은 전량 외국에서 수입되어 왔으며, 최근 Co-60 소선원의 공급부진으로 초기 도입시의 치료시간에 비해 4내지 5배의 시간을 조사하게 되어 대체용 선원의 개발이 크게 요구되고 있다. 이 연구는 국내 하나로 원자로의 중성자를 이용하여 $^{191}$ Ir(n,Υ)$^{192}$ Ir 핵반응을 일으켜 Ir-192 선원 2.87 Ci (밀봉 1.012 Ci)를 생산하고, 고선량률 원격 강내조사선원의 선량특성을 조사하였다. 제작선원에 대한 조사선량률은 아크릴 지지체의 중앙에 아크릴 아프리케이터를 고정하고 선원의 중심으로부터 각각 5, 10, 20 cm 거리에 전리함을 설치하여 일정시간 선원을 노출시켜 측정한 결과 6.36 $\pm$ 0.147 Rm$^2$/GBq-hr (2.350 $\pm$ 0.054 R$cm^2$/mCi-hr)을 결정하였으며, 측정오차는 1$\sigma$ 는 2.2% 였다. 계산선량은 조사선량률 상수 4.69 R$cm^2$/h-mCi 와 Ir-192 에너지 스펙트럼을 이용한 선원자체 및 철에 대한 질량흡수계수를 통해 구했으며, 실제 측정선량과 평균 3.8 % 오차범위에서 일치하였다. 선량 등방성은 선원의 측방향과 축 및 대각선방향으로 전리함을 이용하여 측정한 결과 3 % 이내 균등한 선량을 나타내었으며, 필름선량에서도 균등선량분포를 확인할 수 있었으며, Co-60 선원과 유사한 선량분포를 얻었을 수 있었다. 특히 본 연구의 선량특성조사는 강내조사선량선원 대체용의 선원개발과 선량계획 전산화의 근거가 될 것으로 믿는다.

  • PDF

콘크리트 공동주택과 근린생활 시설의 환경방사선에 관한 연구 (A Study on the Environmental Radiation of Concrete Apartments and Neighborhood Living Facilities)

  • 지태정;곽병준;민병인
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.100-104
    • /
    • 2009
  • In this study, the space gamma dose rates in the apartments structured with concrete were measured in accordance with construction year. In addition, the environmental radiation rates coming from the subway platforms and the road tunnels were analyzed in the equivalent dose by multiplying the absorbed dose with the radiation weighting factors. The space gamma dose rates measured in apartments were higher than those of outdoor which was $0.08{\sim}0.11uSv/h$ in the natural conditions. Especially, the older construction year is, the higher becomes space gamma dose rate. The average gamma dose rates in the subway platforms were measured. In the case of Busan and Daegu subway, the earlier the opening year is, the higher becomes dose rate. However, the dose rates of Seoul subway Lines were high overall, regardless of opening year. Seoul subway Line 6 showed the highest value of 0.21uSv/h. The gamma dose rate in road tunnels was higher than one of the outdoor and increased with opening year like as apartment. In dose rate comparison of the concrete structures with the outdoor, therefore, the space gamma dose rate of indoor is higher than one of the outdoor and the older structures have a higher dose rate.

CHANGING OF RGS TRANSCRIPTS LEVELS BY LOW-DOSE-RATE IONIZING RADIATION IN MOUSE TESTIS

  • Kim, Tae-Hwan;Baik, Ji Sue;Heo, Kyu;Kim, Joong Sun;Lee, Ki Ja;Rhee, Man Hee;Kim, Sung Dae
    • Journal of Radiation Protection and Research
    • /
    • 제40권3호
    • /
    • pp.187-193
    • /
    • 2015
  • Deleterious effects of high dose radiation exposure with high-dose-rate are unarguable, but they are still controversial in low-dose-rate. The regulator of G-protein signaling (RGS) is a negative regulator of G protein-coupled receptor (GPCR) signaling. In addition, it is reported that irradiation stress led to GPCR-mediated mitogen-activated protein kinase (MAPK) and phosphotidylinositol 3-kinase (PI3-k) signaling. The RGS mRNA expression profiles by whole body radiation with low-dose-rate has not yet been explored. In the present study, we, therefore, examined which RGS was modulated by the whole body radiation with low-dose-rate ($3.49mGy{\cdot}h^{-1}$). Among 16 RGS expression tested, RGS6, RGS13 and RGS16 mRNA were down-regulated by low-dose-rate irradiation. This is the first report that whole body radiation with low-dose-rate can modulate the different RGS expression levels. These results are expected to reveal the potential target and/or the biomarker proteins associated with male testis toxicity induced by low-dose-rate irradiation, which might contribute to understanding the mechanism beyond the testis toxicity.

칼라 CCD 영상을 이용한 고휘도 LED 전구의 빔 열화 분석 (Analysis of High Luminance LED Beam Degradation using Color CCD Image)

  • 조재완;최영수;이재철;구인수;홍석붕
    • 제어로봇시스템학회논문지
    • /
    • 제16권6호
    • /
    • pp.586-591
    • /
    • 2010
  • VLC (Visible Light Communication) is a wireless communication method using light that is visible to the human eye. It has a major advantage that it causes no interference to RF-based devices. This makes wireless communication possible in RF hazardous areas such as nuclear facilities. In order to apply VLC communication in harsh environment of nuclear power plant, the high luminance LEDs, which are key components of the VLC communication, have been gamma-ray irradiated at the dose rate of 4kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced color-center was formed in the LED housing cap made of transparent plastic or acryl material. The beam degradations of high luminance LEDs by high dose-rate gammaray irradiation are analyzed using color CCD image processing technology.

자궁 경부암 고선량율 강내조사 치료의 국내 현황과 적정 치료방법 (Current Status of High Dose Rate Brachytherapy in Cervical Cancer in Korea and Optimal Treatment Schedule)

  • 허승재
    • Radiation Oncology Journal
    • /
    • 제16권4호
    • /
    • pp.357-366
    • /
    • 1998
  • Brachytherapy is an essential part of radiotherapy for uterine cervical cancer. The low dose rate (LDR) regimen has been the major technique of intracavitary therapy for cervical cancer. However, there has been an expansion in the last 20 years of high dose rate (HDR) machines using Ir-192 sources. Since 1979, HDR brachytherapy has been used for the treatment of uterine cervical cancer in Korea. The number of institutions employing HDR has been increasing, while the number of low dose rate system has been constant. In 1995, there was a total 27 HDR brachytherapy units installed and 1258 cases of patients with cervical cancer were treated with HDR Most common regimens of HDR brachytherapy are total dose of 30-39 Gy at point A with 10-13 fractions in three fractions per week. 24-32 Gy with 6-8 fractions in two fractions per week, and 30-35 Gy with 6-7 fractions in two fractions per week. The average fractionation regimen of HDR brachytherapy is about 8 fractions of 4.1 Gy each to Point A. In Korea, treatment results for HDR brachytherapy are comparable with the LDR series and appears to be a safe and effective alternative to LDR therapy for the treatment of cervical carcinoma. Studies from the major centers report the five-year survival rate of cervical cancer as. 78-86$\%$ for Stage 1, 68-85$\%$ for stage 11, and 38-56$\%$ for Stage III. World-wide questionnaire study and Japanese questionnaire survey of multiple institutions showed no survival difference in any stages and dose-rate effect ratio (HDR/LDR) was calculated to be 0.54 to 0.58. However the optimum treatment doses and fractionation schemes appropriate to generate clinical results comparable to conventional LDR schemes have yet to be standardized. In conclusion, HDR intracavitary radiotherapy is increasingly practiced in Korea and an effective treatment modality for cervical cancer. To determine the optimum radiotherapy dose and fractionation schedule, a nation-wide prospective study is necessary in Korea. In addition, standardization of HDR application (clinical, computer algorithms, and dosimetric aspects) is necessary.

  • PDF

고선량율 감마선 환경하에서의 카메라 관측성능 (Monitoring Performance of Camera under the High Dose-rate Gamma Ray Environment)

  • 조재완;정경민
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1172-1178
    • /
    • 2012
  • In this paper, the gamma ray irradiation test results of the CCD cameras are described. From the low dose-rate (2.11 Gy/h) to the high dose-rate (150 Gy/h) level, which is the same level when the hydrogen explosion was occurred in the 1~3 reactor unit of the Fukushima nuclear power plant, the monitoring performance of the cameras owing to the speckles are evaluated. The numbers of speckles, generated by gamma ray irradiation, in the image of cameras are calculated by image processing technique. And the legibility of the sensor indicator (dosimeter) owing to the numbers of the speckles is presented.

적외선 열영상을 이용한 가시광 통신모듈의 고선량 감마선조사에 따른 열화 분석 (Analysis of Visible Light Communication Module Degraded by High Dose-Rate Gamma Irradiation using Thermal Infrared Image)

  • 조재완;홍석붕;구인수
    • 제어로봇시스템학회논문지
    • /
    • 제17권12호
    • /
    • pp.1203-1209
    • /
    • 2011
  • In this paper, the degradation evaluation method of VLC (Visible Light Communication) wireless module after high dose rate gamma-ray irradiation using the thermal infrared camera is proposed. First, the heating characteristics of the active devices embedded in the VLC wireless module during the condition of normal operation is monitored by thermal infrared camera. By the image processing technique, the trends of the intensity of the heat emitted by the active devices are calculated and stored. The feature of the blob area including the area of the active devices in the thermal infrared image is extracted and stored. The feature used in this paper is the mean value of the gray levels in the blob area. The same VLC module has been gamma irradiated at the dose rate of about 4.0 kGy/h during 72 hours up to a total dose of 288 kGy. And then, the heating characteristics of the active devices embedded in the VLC wireless module after high dose gamma ray irradiation is observed by thermal infrared camera. The high dose gamma-ray induced degradation of the active devices embedded in the VLC module was evaluated by comparing the mean value of the blob area to the one of the same blob area of the VLC module before the gamma ray irradiation.