• Title/Summary/Keyword: high Tg

Search Result 894, Processing Time 0.026 seconds

Ultrahigh Efficiency from Novel Blue Emitters Using a Rational Molecular Design

  • Kim, Soo-Kang;Park, Young-Il;Park, Jong-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.921-924
    • /
    • 2008
  • We investigated new deep blue emitting materials including a novel side group such as CB-203. CB-203 shows relatively 40% increased PL quantum efficiency and higher Tg of $30^{\circ}C$ compared to MADN. It exhibits high External Quantum Efficiency (EQE) of 7.18% that is two times bigger than MADN's, which is the best efficiency in case of non-doped blue fluorescence OLED device to our knowledge. And deep blue emitting materials with a new core structure (CB-301) have been synthesized. CB-301 exhibit excellent blue fluorescence properties. Undoped OLED devices using CB-301 as blue emitters was found to deep blue CIE value (0.154, 0.078) and exhibit high luminance efficiencies of 2.01cd/A at $10\;mA/cm^2$.

  • PDF

Synthesis of Acrylic Resins with High-Solids Contents for HS Coatings (하이솔리드 도료용 고 고형분인 아크릴수지의 합성에 관한 연구)

  • Yang, In-Mo;Wu, Jong-Pyo;Park, Hong-Soo;Kim, Seong-Kil
    • Journal of the Korean Applied Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.233-239
    • /
    • 2000
  • To prepare an environmental friendly high-solid coatings an acrylic resin containing 80% of solid content was synthesized by addition polymerization of caprolactone acrylate, n-butyl acrylate, ethyl methacrylate, and 2-hydroxyethyl methacrylate. The conversion was $78{\sim}93%$ and the prepared resin's physical properties are as follows: viscosity, $212{\sim}3424cps: $M_{n}$ $1740{\sim}2400$. There was a trend that viscosity and molecular weight of the resin increased with Tg, but no direct proportionality was observed.

Hypolipidemic and Antioxidative Properties of Tocotrienol-rich Fraction (TRF) Supplementation in High Fat-fed Rats

  • Choi, Young-Min;Lee, Jun-Soo
    • Food Science and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1528-1531
    • /
    • 2009
  • In this study, we investigated a dose-dependent hypolipidemic and antioxidant effects of tocotrienol-rich fraction (TRF) from grape seeds. After induction of hyperlipidemia for 4 weeks, rats were supplemented with different dose (5, 25, and 50 mg/kg BW/day) of TRF for 1 week. Oral administration of TRF (50 mg/kg BW/day) decreased the plasma triglyceride (TG, 162.6 mg/dL), total cholesterol (TC, 83.7 mg/dL), low density lipoprotein-cholesterol (LDL-C, 20.3 mg/dL), malondialdehyde contents (MDA, 3.3 nmol/dL), and atherogenic index (AI, 2.0) compare to high-fat diet group. These data suggest that TRF supplementation has significant health benefits through the modulation of physiological functions that include various atherogenic lipid profiles and antioxidative status in hyperlipidemia.

Electrical and mechanical properties of elastomer epoxy by addition of liquid elastomer (엘라스토머 첨가량에 의한 탄성에폭시의 기계 및 전기적 특성)

  • Kim, Eung-Kwon;Yoon, Byeong-Don;Kang, Chun-Gi;Park, Dae-Hee;Song, Joon-Tae;Lee, Kwan-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.259-260
    • /
    • 2008
  • In this paper, we fabricated elastomer epoxy specimens by added liquid elastomer to improve the mechanical and electrical properties instead of previous high-voltage epoxy materials. As increased additive contents, glass transient temperature (Tg) was continually decreased in DSC (differential scanning calorimetry). Among specimens, 15 phr sample showed the mechanical and electrical properties similar of high-voltage epoxy in modulus, break-down and arc test. From the optimized condition of elastic epoxy, we confirmed a chance of application for high-voltage materials and power electrical instruments.

  • PDF

The Effect of Natural Mate Tea Extract on the Body Weight and Biochemical Biomarker in High Fat Diet-Obese(ob/ob) Mice (천연마테차 물추출물의 고지방식이 비만쥐의 체중과 생화학적 변화에 미치는 영향)

  • Kim, Sang-Tae;Hwang, Cho-Won;Kim, Young-Kyoon
    • YAKHAK HOEJI
    • /
    • v.56 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, we investigated the anti-obese activity of sevennight extract in high fat diet-ob/ob C57BL/6J mice by oral administered for 1 weeks. Mate water extract (MATEWi) was found to lower whole body and epididymal adipose tissue weights and lowered plasma levels of triglyceride (TG) and total cholesterol (TC), HDL and LDL, compared to those in high fat fed ob/ob group. These results suggest that Mate extract ameliorates obesity through activation of lipogenic enzymes and FA oxidation resulting from phosphorylation of AKT and GSK-$3{\beta}$, and could be developed as a potential therapeutic agent for obese mices.

The Association of Urine Microalbumin and Pulse Pressure in Korean Adults (한국 성인에서 뇨 중 Microalbumin과 맥압의 관련성)

  • Gee, Mee Young;Yoon, Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.3
    • /
    • pp.183-187
    • /
    • 2016
  • The aim of this study was to assess the association between microalbumin and pulse pressure (PP) in Korean adults. The study subjects were Korean adults 20 years or older (n=4,948) who participated in the Korea National Health and Nutrition Examination Survey 2012. The urine microalbumin level ($M{\pm}SE$) was significantly higher (p=0.047) in the high PP group (PP>60.0 mmHg) [$33.02{\pm}4.93{\mu}g/mL$ (95% confidence interval (CI), 23.37~42.68)] than the normal PP group ($PP{\leq}60.0mmHg$) [$22.57{\pm}1.63{\mu}g/mL$ (95% CI, 19.36~25.77)], after adjusting for age, gender, smoking, drinking, regular exercising, WM, BMI, TC, TG, HDL-C, FBG, BUN, creatinine, and urine creatinine. In conclusion, pulse pressure was associated with the microalbumin level in Korean adults.

Effect of Calcination Temperature on Cobalt Adsorption Capacity of$ZrO_2$ prepared by Sol-Gel Process (졸-겔법으로 제조한 $ZrO_2$ 의 코발트 흡착량에 미치는 하소온도의 영향)

  • 김유환;김용익;배성렬
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.4
    • /
    • pp.432-440
    • /
    • 1996
  • ZrO2 gel was prepared under pH 10 alkaline condition by sol-gel process and was investigated as a function of calcination temperature and effect of calcination temperature on cobalt adsorption capacity. The ZrO2 powder prepared by sol-gel process was calcined at 600, 800, 1000, 1200, 140$0^{\circ}C$ and analyzed by X-ray diffractometry. SEM specific surface area by BET nitrogen adsorption FT-IR and TG-DTA technique. It was shown that cobalt adsorption capacity of ZrO2 prepared under pH 10 alkaline condition and then calcined at $600^{\circ}C$ in high temperature was determined to be larger than that of ZrO2 at various calcination temperature. The specific surface area of ZrO2 calcined at $600^{\circ}C$ was 24.03m2/g and cobalt adsorption capacity at 25$0^{\circ}C$ high-temperature water was 0.16m-eq/g.

  • PDF

Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard (물 흡수선량 표준에 기반한 선량교정 프로그램 개발)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.175-183
    • /
    • 2003
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma (or exposure) calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to the uncertainty of the physical parameters used. Recently, the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocols(IAEA TRS-398 and AAPM TG-51). The dose calibration programs for these two protocols were developed. This program for high energy photon and electron beams was also developed for users to use in a window environment using the Visual C++ language. The formalism and physical parameters of these two protocols were strictly applied to the program. The tables and graphs of the physical data, and the information of ion chambers were numericalized for their incorporation into a database. This program can be useful in developing new dosimetry protocols in Korea.

  • PDF

Improvement of Lipid Metabolism and Antihyperglycemic by Lentinus edodes in High Fat-fed and Streptozotocin-treated Rats (고지방과 streptozotocin으로 유도한 제 2형 당뇨에서 표고버섯이 지질대사와 항당뇨 효능에 미치는 영향)

  • Kim, Gye Yeop;Yoon, Young Jeoi;Kim, Eun Jung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.2
    • /
    • pp.196-201
    • /
    • 2013
  • Abnormal regulation of glucose and impaired lipid metabolism that result from a defective or deficient insulin are the key etiological factor in type 2 diabetes mellitus (T2DM). The our study evaluated the beneficial effect of diet supplementation with Lentinus edodes on hyperglycemia and lipid metabolism in normal and type 2 diabetic rats. The animals were divided into 4 groups: group I(control) rats were fed standard diet (12% of calories as fat); group II (T2DM) rats were fed HFD (40% of calories as fat) for 2 weeks and then injected with STZ (50 mg/kg); group III and group IV rats were continually fed a diet containing 1% and 10% Lentinus edodes for 4 weeks after T2DM induction, respectively. After 4 weeks we determined biochemical parameters such as glucose, insulin concentration, serum total cholesterol (TC), triglycerides (TG), high-density lipoprotein (HDL), and glycosylated hemoglobin (HbA1c) concentration were also measured. There was a significant reduction in serum TC and TG in the Lentinus edodes supplement groups. The Lentinus edodes diet supplementation were found to have a potent lipid metabolism improvement as well as LDL concentration decreased and HDL concentration was increased. Concentrations of blood glucose and HbA1c in the experimental groups II were significantly decreased after 4 weeks compared with the control group. The Lentinus edodes diet supplementation is useful in regulating the glucose level, improves the insulin, HbA1c, serum lipid metabolism in experimental diabetic rats. We suggest that Lentinus edodes supplementation may have the control effects of diabetes mellitus by improving blood glucose control and lipid metabolism.

Reliability Enhancement of Anisotropic Conductive Adhesives Flip Chip on Organic Substrates by Non-Conducting Filler Additions

  • Paik, Kyung-Wook;Yim, Myung-Jin
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.04a
    • /
    • pp.9-15
    • /
    • 2000
  • Flip chip assembly on organic substrates using ACAs have received much attentions due to many advantages such as easier processing, good electrical performance, lower cost, and low temperature processing compatible with organic substrates. ACAs are generally composed of epoxy polymer resin and small amount of conductive fillers (less than 10 wt. %). As a result, ACAs have almost the same CTE values as an epoxy material itself which are higher than conventional underfill materials which contains lots of fillers. Therefore, it is necessary to lower the CTE value of ACAs to obtain more reliable flip chip assembly on organic substrates using ACAs. To modify the ACA composite materials with some amount of conductive fillers, non-conductive fillers were incorporated into ACAs. In this paper, we investigated the effect of fillers on the thermo-mechanical properties of modified ACA composite materials and the reliability of flip chip assembly on organic substrates using modified ACA composite materials. For the characterization of modified ACAs composites with different content of non-conducting fillers, dynamic scanning calorimeter (DSC), and thermo-gravimetric analyzer (TGA), dynamic mechanical analyzer (DMA), and thermo-mechanical analyzer (TMA) were utilized. As the non-conducting filler content increased, CTE values decreased and storage modulus at room temperature increased. In addition, the increase in tile content of filler brought about the increase of Tg$^{DSC}$ and Tg$^{TMA}$. However, the TGA behaviors stayed almost the same. Contact resistance changes were measured during reliability tests such as thermal cycling, high humidity and temperature, and high temperature at dry condition. It was observed that reliability results were significant affected by CTEs of ACA materials especially at the thermal cycling test. Results showed that flip chip assembly using modified ACA composites with lower CTEs and higher modulus by loading non-conducting fillers exhibited better contact resistance behavior than conventional ACAs without non-conducting fillers.ers.

  • PDF