• Title/Summary/Keyword: height measurements

Search Result 1,379, Processing Time 0.024 seconds

The Variation and Classification of Somatotype of Female Students Aged from 12 to 18 in Their Growth Period(Part I) (성장기 여학생 (12~18세)의 체형 변이 및 체형 분류(제1보))

  • 이혜주;함옥상
    • The Research Journal of the Costume Culture
    • /
    • v.9 no.2
    • /
    • pp.319-332
    • /
    • 2001
  • This study attempts to measure body sizes and somatotypes of 844 female middle and high students girls in their growth period and to investigate characteristics of each of the measured somatotypes. The data used for this study were 50 items of body sizes obtained from anthropometric measurements. The purposes of the study are as follows: 1. to analyze physical characteristics according to age. 2. to extract factors of somatotypes using factor analyses. 3. to classify somatotypes according to physical characteristics using cluster analyses. The study results were as follows: 1. TH anthropometric measurements indicated that three existed collective patterns of somatotypes across Group I(12∼13 years old), Group II(14∼15 years old), and Group III(16∼18 years old). 2. Through factor analyses, 6 factors were yielded from each age group. The cumulative proportions of these factors were 77% for Group I, 75% for Group II, and 72% for Group III. Factor I indicates a horizontal size factor and Factor 2 indicates a vertical size factor. 3. Group I and Group II ere classified into 5 types and Group III was classified as 3 types. In Group I, middle height and a little slim types were most prevalent(28%). In Group II, low height and very slim types were most prevalent(28.9%). Finally, In Group III, low height and slim types were most prevalent(4.6%)

  • PDF

Determination of Marine Gravity anomaly Around the Korean Peninsula from GEOSAT Satellite Altimeter Measurements (GEOSAT 인공위성 해면고도 관측자료를 이용한 한반도 주변해역에서 의 중력이상의 결정)

  • 양철수;최광선
    • 한국해양학회지
    • /
    • v.29 no.4
    • /
    • pp.383-391
    • /
    • 1994
  • Sea surface height geoidal undulation, and gravity anomaly derived from satellite altimeter measurements are described. Assuming mean sea surface height (MSSH) as geoidal undulation, MSSH was converted to gravity anomaly. the result shows that the gravity anomaly derived from satellite altimeter data can be mapped to an accuracy of the surface ship gravity measurements. The data used for the conversion is the two-year mean sea surface height obtained from GEOSAT Exact Repeat Mission. The conversion was carried out using fast Fourier transform with plane approximation. In this process, the so called remove-restore method was employed.

  • PDF

The Relationships between Body Cathexis and Clothing Satisfaction of Middle- and High-School Girls (여자 중.고교생의 신체만족도와 의복만족도의 관계연구)

  • 전경숙
    • Journal of the Korean Society of Costume
    • /
    • v.51 no.5
    • /
    • pp.5-16
    • /
    • 2001
  • The purpose of the study was to investigate the body cathexis, ideal body shape, clothing satisfaction and their interrelationships. The subjects were 445 middle- and high- school girls. The findings were as follows : the subjects were more satisfied with their face appearance than body parts. They were very unsatisfied with thigh. leg and weight. Generally they were more satisfied with upper body than lower body, and more satisfied with length measurements than girth measurements. They accepted 169.19cm as ideal height and 49.18kg as ideal weight. The middle-school girls wanted to be taller than high-school girls by 3cm. But the ideal weight of both were almost same. The Rohrer indices indicated that the subjects were normal to slender type. But the Rohrer indices calculated using ideal height and ideal weight showed that the subjects thought extremely slender type as ideal body shape. The attitude of body was evaluated by two factors. the awareness of body shape and the physical attractiveness. The awareness of body shape was deeply influenced by girth measurements and lower body parts. And physical attractiveness was severely affected by face appearance. Weight was more important than height in regard to body cathexis. The ideal body shape was independent of individual situation but was formed by social value. The satisfaction of clothing in terms of design related aspects was influenced by body cathexis. Also the more satisfied with their body. the more they felt comfortable for their clothing. The body cathexis was interrelated with the satisfaction of clothing in some aspects.

  • PDF

Age Estimation by Radiological Measuring Pulp Chamber of Mandibular First Molar in Korean Adults

  • Jeon, Hye-Mi;Kim, Jin-Hwa;Heo, Jun-Young;Ok, Soo-Min;Jeong, Sung-Hee;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.4
    • /
    • pp.146-154
    • /
    • 2015
  • Purpose: The purpose of present study was to develop a method for assessing the chronological age of Korean adults based on the relationship between age and size of pulp cavity using dental radiographs of mandibular first molars. Methods: A total of 325 dental radiographs of Korean adults with known age and gender were selected for the study (199 males and 126 females) which were taken in the period between January 2009 and June 2014 at the Pusan National University Dental Hospital. The measurements were carried out on both orthopantomographs (OPGs) and intraoral periapical radiographs of mandibular first molar and the following ratios were calculated: pulp chamber floor height ratio (F/L), pulp chamber ceiling height ratio (R/L), and pulp chamber depth ratio (D/L). Results: The ratios of measurements on intraoral periapical images of mandible first molar generally produce more reliable data than the measurements on OPGs. The pulp chamber floor height ratio and pulp chamber thickness ratio showed significant correlation with age, whereas the pulp chamber ceiling height ratios showed weak correlation with age. It was found that the best correlations between the ratios and age were found for pulp chamber thickness ratios (r=-0.731 to -0.751). The multiple regression models were derived using 3 ratios that were significantly correlated with age. The determination coefficients ($R^2$) of the models ranged from 0.556 to 0.596. Conclusions: Our results indicate that the pulp chamber thickness and pulp chamber floor height in mandibular first molar are an age-dependent variable in adults which can be used to estimate age with reasonable accuracy. The higher image quality of dental radiographs will probably narrow the age estimation error and improve dental age estimation.

A CEPHALOMETRIC EVALAUATION OF ANTERIOR OPENBITE MALOCCLUSIONS TREATED BY MULTILOOP EDGEWISE ARCHWIRE TECHNIQUE (Multiloop edgewise Archwire 기법으로 치료된 전치 개교 증례의 두부방사선사진 계측학적 평가)

  • Moon, Seong-Cheol;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.565-606
    • /
    • 1993
  • The purpose of this study was to evaluate the change of before and after treatment of anterior openbite malocclusions treated by Multiloop Edgewise Archwire technique. The openbite sample consisted of 4 male and 12 female adults, treated with nonextraction or third molar extraction. The normal sample consisted of 58 subjects, which have pleasing facial profile and normal occlusion and no experience of orthodontic or prosthodontic treatment. The 58 subjects of normal sample were subdivided by cephalemetric vertical relationship of face. The 40 subjects, cephalometric vertical relationship of face was in normal range, classified as Normal Sample group 1. The 18 subjects, increased cephalometric vertical relationship of face, classified as Normal Sample group 2. The computerized cephalometric analysis was accomplished with 50 reference points for 22 skeletal measurements, 46 dentoalveolar measurements, 8 soft tissue measurements. Statistical analysis of the data was carried out with paired t-test, Student's t-test, and DUNCAN test using SAS(PC version), The results were as follows : 1. There were no statistically significant differences in skeletal measurement between before and after treatment. The major changes were in dentoalveolar region. 2. After treatment, the long axis of maxillary and mandibular posterior teeth were distally tipped-back, and uprighted to bisected occlusal plane. The interincisal angle was increased. 3. There were no statistically significant increase in the upper posterior dental height and statistically significant decrease in the lower posterior dental height. The upper anterior dental height was increased, but there was no statistically significant increase in the absolute upper anterior dental hight. The lower anterior dental height was increased. 4. After treatment, the maxillary occlusal plane to palatal plane angle and the mandibular occlusal plane to mandibular plane angle were statistically significant increased. Then, there were no statistically significant difference between after treatment group and normal sample group 2. 5. After treatment, the percentage of upper lip length to upper anterior dental height was decreased. Then, There were no statistically significant difference between after treatment group and normal sample group 2.

  • PDF

Analysis of Technical Error of Manual Measurements (직접 측정한 인체치수의 기술적 오차 분석)

  • Park, Jinhee;Nam, Yun Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.4
    • /
    • pp.641-649
    • /
    • 2016
  • Highly precision body measurements represent basic data required by industry and researches who wish to utilize information about the human body. The proficiency and expertise of the measurers have a significant influence on the error and accuracy of data when various parts from multiple subjects' bodies are measured. Therefore, in order to measure accurate body measurements (when measuring bodies directly), it is necessary to conduct objective analyses on errors. This study calculated the Relative Technical Error of Measurement (%TEM) using data that measured each of 24 subjects and discussed errors and methods to reduce errors by conducting comparison analysis based on measured items and objects. The result of analysis indicated that the errors based on age and gender of the objects of measurement were minor; however, there were comparatively distinct differences in measured errors based on measured items. 'Right and left Shoulder Angle' for all measured subjects displayed the greatest errors and standard deviations. 'Height' dimension, Lateral Malleolus Height and Head Height had big errors; in addition, 'Circumference', Neck Base Circumference and Armscye Circumference also had big errors. More careful measurements of such items with big errors require additional educational plan such as a proposal for more objective and detailed measurement methods. Items with small errors but big standard deviations such as Waist Circumference, Calf Circumference, Minimum Leg Circumference, Chest Circumference, Hip Circumference and Waist Circumference confirmed that errors for them greatly decreased with repeated experiments and resultant measurers increased proficiency; consequently, repeated measuring experiments for these items greatly enhance accuracy.

A Study on Changes in Body Shape of MZ Generation (2030s) Women for Clothing Construction - Focused on the 7th and 8th Size Korea's Anthropometric Data - (의복설계를 위한 MZ세대(2030대) 여성의 체형 변화 연구 - 제 7차, 제 8차 사이즈코리아 직접 측정치를 기준으로 -)

  • Kim, Eun-Kyong;Kim, Ji-Eun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.24 no.3
    • /
    • pp.111-125
    • /
    • 2022
  • Recently, the MZ generation has been leading overall fashion trends, and fashion companies focus on design, marketing, and new products targeting the MZ generation. However, it is expected that a fit problem may occur if the M and Z generations are combined when producing clothing. Therefore, this study aims to analyze the differences between the two groups by comparing the body size according to the classification of the M and Z generations. In addition, this study analyzes whether the body shape of the MZ generation is different from the past generations and analyzes major changes in body size for clothing manufacturing through graphical visualization. As for the research method, a t-test was conducted to verify the significant difference between the measurements for each age group. Generation M was defined as those who are 27-39 years old, and Generation Z was defined as those who are 20-26 years old. In order to examine the changes in body measurements according to the measurement year, the 7th Size Korea and 8th Size Korea data were analyzed. In order to examine the visual changes according to the measurement year and age group, major measurements of clothing construction were analyzed. As a result, it was found that Generation M had a significantly higher height item than Generation Z. Also, in terms of circumference, width, and thickness, Generation M was larger than Generation Z. But the size of the bra cup was larger in Generation Z than Generation M. As a result of analyzing the body size changes, in the height item, the 8th Size Korea measurements were found to be significantly higher in shoulder height and navel level waist height. In the length and circumference items, the 8th Size Korea measurements were larger than the 7th. In the width, thickness, and other items, the 8th measurements were larger than the 7th.

Reproducibility of panoramic radiography in patients (임상에서 촬영되는 파노라마 방사선사진의 재현성 조사)

  • Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.35 no.3
    • /
    • pp.115-119
    • /
    • 2005
  • Purpose : To evaluate the magnification error percentage in repeatedly taken panoramic radiographs of same patient and machine. Materials and Methods : 92 panoramic radiographs from 46 patients were traced and 30 horizontal and vertical measurements were made with digital sliding caliper. The results were compared with paired t-test. Results : There was no statistically significant difference between the two measurements. The overall difference as percentage error was $6.19\pm5.60\%$. The largest error as $14.61\pm12.44\%$ was found at condylar height 1, and smallest as $1.86\pm1.61\%$ at mandibular height. Overall vertical error excluding condylar height 1 was $3.76\pm3.97\%$, and the horizontal error $6.88\pm5.92\%$. Conclusion . Repeatedly taken panoramic radiographs of the same patient and machine was reliable since there was no significant percentage error difference but the percentage error ranged from $1.86\pm1.61\%\;to\;14.61\pm12.44\%$ indicating the error depends on the measuring site.

  • PDF

Uncertainty in the Measurement of Radiative Energy Attenuation through Packed Spheres (구립자층내의 복사에너지 감쇠량계측의 불확정성에 관한 연구)

  • 김춘식;김경근;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.23-29
    • /
    • 1991
  • Uncertainty is studied in the measurements of average packing density, thickness of packed spheres and transmittance in the experiments to study the effect of the bed height and the existence of the bed side walls on the transmittance of radiative energy through packed spheres. The packing density of the bed is obtained by counting the number of the spheres packed in three pipes with different heights. The bed height of the packed spheres is estimated from the number of spheres contained in the bed by using the relation between the bed height and the sphere number. The transmittance is obtained by dividing the intensity of the transmitted laser beam by the incoming-beam intensity. From the analysis, the uncertainity in the measurements of transmittance is shown to be less than 10.2%(95% coverage).

  • PDF

Comparison of Electrical Properties between Sputter Deposited Au and Cu Schottky Contacts to n-type Ge

  • Kim, Hogyoung;Kim, Min Kyung;Kim, Yeon Jin
    • Korean Journal of Materials Research
    • /
    • v.26 no.10
    • /
    • pp.556-560
    • /
    • 2016
  • Using current-voltage (I-V) and capacitance-voltage (C-V) measurements, the electrical properties of Au and Cu Schottky contacts to n-Ge were comparatively investigated. Lower values of barrier height, ideality factor and series resistance were obtained for the Au contact as compared to the Cu contact. The values of capacitance showed strong dependence on the bias voltage and the frequency. The presence of an inversion layer at the interface might reduce the intercept voltage at the voltage axis, lowering the barrier height for C-V measurements, especially at lower frequencies. In addition, a higher interface state density was observed for the Au contact. The generation of sputter deposition-induced defects might occur more severely for the Au contact; these defects affected both the I-V and C-V characteristics.