Browse > Article
http://dx.doi.org/10.5850/JKSCT.2016.40.4.641

Analysis of Technical Error of Manual Measurements  

Park, Jinhee (Dept. of Textiles, Merchandising and Fashion Design, Seoul National University)
Nam, Yun Ja (Dept. of Textiles, Merchandising and Fashion Design, Seoul National University/ Research Institute of Human Ecology, Seoul National University)
Publication Information
Journal of the Korean Society of Clothing and Textiles / v.40, no.4, 2016 , pp. 641-649 More about this Journal
Abstract
Highly precision body measurements represent basic data required by industry and researches who wish to utilize information about the human body. The proficiency and expertise of the measurers have a significant influence on the error and accuracy of data when various parts from multiple subjects' bodies are measured. Therefore, in order to measure accurate body measurements (when measuring bodies directly), it is necessary to conduct objective analyses on errors. This study calculated the Relative Technical Error of Measurement (%TEM) using data that measured each of 24 subjects and discussed errors and methods to reduce errors by conducting comparison analysis based on measured items and objects. The result of analysis indicated that the errors based on age and gender of the objects of measurement were minor; however, there were comparatively distinct differences in measured errors based on measured items. 'Right and left Shoulder Angle' for all measured subjects displayed the greatest errors and standard deviations. 'Height' dimension, Lateral Malleolus Height and Head Height had big errors; in addition, 'Circumference', Neck Base Circumference and Armscye Circumference also had big errors. More careful measurements of such items with big errors require additional educational plan such as a proposal for more objective and detailed measurement methods. Items with small errors but big standard deviations such as Waist Circumference, Calf Circumference, Minimum Leg Circumference, Chest Circumference, Hip Circumference and Waist Circumference confirmed that errors for them greatly decreased with repeated experiments and resultant measurers increased proficiency; consequently, repeated measuring experiments for these items greatly enhance accuracy.
Keywords
Technical Error of Measurement; Relative TEM; Body measurement; Manual measurements;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Chumlea, W. C., Roche, A. F., & Rogers, E. (1984). Replicability for anthropometry in the elderly. Human Biology, 56(2), 329-337.
2 de Onis, M., Onyango, A. W., Van den Broeck, J., Chumlea, W. C., & Martorell, R. (2004). Measurement and standardization protocols for anthropometry used in the construction of a new international growth reference. Food and Nutrition Bulletin, 25(1 Suppl1), S27-S36. doi:10.1177/15648265040251S104   DOI
3 Han, H., Nam, Y. J., & Choi, K. M. (2006). The characteristics of 3D measurements of Korean adult women compared with manual measurements. Proceedings of the Ergonomics Society of Korea, Spring Conference, Korea, 285-290.
4 International Standards Organization. (1996). ISO 7250:1996 Basic human body measurements for technological design. Geneva: Author.
5 International Standards Organization. (2003). BS EN ISO 15535:2003 General requirements for establishing anthropometric databases. Geneva: Author.
6 International Standards Organization. (2005). BS EN ISO 20685:2005 3-D scanning methodologies for internationally compatible anthropometric databases. Geneva: Author.
7 Korean Agency for Technology and Standard. (2014, December 6). 2015 한국인 인체치수측정조사 대비 프로토콜 고도화 방안에 대한 연구 [A study on improving the protocol for anthropometric survey of Koean, 2015]. Eumseong: Author.
8 Korea Research Institute of Standards and Science. (2008, November). 6차 인체치수조사 사업 기반조성 최종 보고서[The foundation construction work for 6th anthropometric survey of Korea]. Daejeon: Author.
9 Norton, K., Olds, T., & Australian Sports Commission. (1996). Anthropometrica: A textbook of body measurement for sports and health courses. Sydney: UNSW Press.
10 Park, S. M., & Nam, Y. J. (2012). The verification of accuracy of 3D body scan data - Focused on the cyberware WB4 whole body scanner -. Journal of the Korea Fashion & Costume Design Association, 14(1), 81-96.
11 Park, S. M., Nam, Y. J., & Park, J. W. (2009). A study for quality improvement of three-dimensional body measurement data. Journal of the Ergonomics Society of Korea, 28(4), 117-124.   DOI
12 Whang, M. C., Yoo, J. W., & Kim, J. Y. (2002). A study to determine allowable measurement error during anthropometric measurement. Journal of the Ergonomics Society of Korea, 21(4), 107-115.
13 Perini, T. A., de Oliveira, G. L., dos Santos Ornellas, J., & de Oliveira, F. P. (2005). Technical error of measurement in anthropometry. Revista Brasileira de Medicina do Esporte, 11(1), 86-90. doi:10.1590/S1517-86922005000100009   DOI
14 Ulijaszek, S. J., & Kerr, D. A. (1999). Anthropometric measurement error and the assessment of nutritional status. British Journal of Nutrition, 82(3), 165-177.   DOI